Country | Identifier | Name | |
---|---|---|---|
AUSTRALIA | ExTC | Ex Testing and Certification Pty Ltd (ExTC, TRA, ITA) | |
Contact
Ajay
Maira
30 Kennington Drive Postal Address +61 2 4964 5801 Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 2: Equipment protection by pressurized enclosures 'p' IEC60079: Part 5: Equipment protection by powder filling 'q' IEC60079: Part 6: Equipment protection by oil immersion 'o' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 13: Equipment protection by pressurized room "p" and artificially ventilated room "v" IEC60079: Part 15: Equipment protection by type of protection 'n' IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 25: Intrinsically safe electrical systems IEC60079: Part 26: Equipment with equipment protection level (EPL) Ga IEC60079: Part 27: Fieldbus intrinsically safe concept (FISCO) IEC60079: Part 28: Protection of equipment and transmission systems using optical radiation IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' IEC60079: Part 33: Equipment protection by special protection 's' IEC60079: Part 35-1: Caplights for use in mines susceptible to firedamp - General requirements - Construction and testing in relation to the risk of explosion IEC/TS60079: Explosive atmospheres - Part 46: Equipment assemblies IEC61241: Part 0: General requirements - Electrical apparatus for use in the presence of combustible dust IEC61241: Part 1: Protection by enclosures 'tD' IEC61241: Part 1-1: Electrical apparatus protected by enclosures and surface temperature limitation - Specification for apparatus IEC61241: Part 4: Type of protection 'pD' IEC62013: Part 1: General requirements - Construction and testing in relation to the risk of explosion - Caplights for use in mines susceptible to firedamp ISO80079: Part 36: Non-electrical equipment for explosive atmospheres - Basic method and requirements ISO80079: Part 37: Non-electrical equipment for explosive atmospheres - Non electrical type of protection constructional safety "c", control of ignition source "b", liquid immersion "k" DS2015/001A: IECEx Assessment and Certification of Equipment assemblies |
|||
AUSTRALIA | SIMTARS | Safety in Mines,Testing and Research Station (SIM) | |
Contact
Geoffrey
Barnier
Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 2: Equipment protection by pressurized enclosures 'p' IEC60079: Part 5: Equipment protection by powder filling 'q' IEC60079: Part 6: Equipment protection by oil immersion 'o' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 13: Equipment protection by pressurized room "p" and artificially ventilated room "v" IEC60079: Part 15: Equipment protection by type of protection 'n' IEC60079: Part 16: Artificial ventilation for the protection of analyser (s) houses IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 25: Intrinsically safe electrical systems IEC60079: Part 26: Equipment with equipment protection level (EPL) Ga IEC60079: Part 27: Fieldbus intrinsically safe concept (FISCO) IEC60079: Part 28: Protection of equipment and transmission systems using optical radiation IEC60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC/IEEE60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' IEC60079: Part 33: Equipment protection by special protection 's' IEC60079: Part 35-1: Caplights for use in mines susceptible to firedamp - General requirements - Construction and testing in relation to the risk of explosion IEC61241: Part 0: General requirements - Electrical apparatus for use in the presence of combustible dust IEC61241: Part 1: Protection by enclosures 'tD' IEC61241: Part 1-1: Electrical apparatus protected by enclosures and surface temperature limitation - Specification for apparatus IEC61241: Part 4: Type of protection 'pD' IEC61241: Part 11: Protection by intrinsic safety 'iD' IEC61241: Part 18: Protection by encapsulation 'mD' IEC62013: Part 1: General requirements - Construction and testing in relation to the risk of explosion - Caplights for use in mines susceptible to firedamp IEC62086: Part 1: General and testing requirements - Electrical apparatus for explosive gas atmospheres – Electrical resistance trace heating Notes
|
|||
AUSTRALIA | TestSafe | TestSafe Australia (TSA) (MSC) | |
Contact
Ujen
Singh
919 Londonderry Road Postal Address + 61 2 4724 4900 Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 2: Equipment protection by pressurized enclosures 'p' IEC60079: Part 5: Equipment protection by powder filling 'q' IEC60079: Part 6: Equipment protection by oil immersion 'o' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 13: Equipment protection by pressurized room "p" and artificially ventilated room "v" IEC60079: Part 15: Equipment protection by type of protection 'n' IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 19: Equipment repair, overhaul and reclamation IEC60079: Part 25: Intrinsically safe electrical systems IEC60079: Part 26: Equipment with equipment protection level (EPL) Ga IEC60079: Part 27: Fieldbus intrinsically safe concept (FISCO) IEC60079: Part 28: Protection of equipment and transmission systems using optical radiation IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' IEC60079: Part 33: Equipment protection by special protection 's' IEC60079: Part 35-1: Caplights for use in mines susceptible to firedamp - General requirements - Construction and testing in relation to the risk of explosion IEC/TS60079: Explosive atmospheres - Part 46: Equipment assemblies IEC61241: Part 0: General requirements - Electrical apparatus for use in the presence of combustible dust IEC61241: Part 1: Protection by enclosures 'tD' IEC61241: Part 1-1: Electrical apparatus protected by enclosures and surface temperature limitation - Specification for apparatus IEC62013: Part 1: General requirements - Construction and testing in relation to the risk of explosion - Caplights for use in mines susceptible to firedamp ISO80079: Part 36: Non-electrical equipment for explosive atmospheres - Basic method and requirements ISO80079: Part 37: Non-electrical equipment for explosive atmospheres - Non electrical type of protection constructional safety "c", control of ignition source "b", liquid immersion "k" DS2015/001A: IECEx Assessment and Certification of Equipment assemblies |
|||
BRAZIL | UL do Brasil | UL Solutions (BR) | |
Contact
Geoff
Slater
+61 2 4628 4690 Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 2: Equipment protection by pressurized enclosures 'p' IEC60079: Part 5: Equipment protection by powder filling 'q' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 15: Equipment protection by type of protection 'n' IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 25: Intrinsically safe electrical systems IEC60079: Part 26: Equipment with equipment protection level (EPL) Ga IEC60079: Part 27: Fieldbus intrinsically safe concept (FISCO) IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' |
|||
BRAZIL | NCC | NCC Certificações do Brasil Ltda. (NCC) | |
Contact
Wilson
Bonato
Avenida Orosimbo Maia, +55 19 2517 9646 +55 19 3232 9828 Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 2: Equipment protection by pressurized enclosures 'p' IEC60079: Part 5: Equipment protection by powder filling 'q' IEC60079: Part 6: Equipment protection by oil immersion 'o' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 15: Equipment protection by type of protection 'n' IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 25: Intrinsically safe electrical systems IEC60079: Part 26: Equipment with equipment protection level (EPL) Ga IEC60079: Part 27: Fieldbus intrinsically safe concept (FISCO) IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' IEC61241: Part 0: General requirements - Electrical apparatus for use in the presence of combustible dust IEC61241: Part 4: Type of protection 'pD' IEC61241: Part 11: Protection by intrinsic safety 'iD' IEC61241: Part 18: Protection by encapsulation 'mD' |
|||
CANADA | QPS | QPS Evaluation Services Inc. (QPS) | |
Contact
Rob
Kohuch
Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 2: Equipment protection by pressurized enclosures 'p' IEC60079: Part 5: Equipment protection by powder filling 'q' IEC60079: Part 6: Equipment protection by oil immersion 'o' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 13: Equipment protection by pressurized room "p" and artificially ventilated room "v" IEC60079: Part 15: Equipment protection by type of protection 'n' IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 25: Intrinsically safe electrical systems IEC60079: Part 26: Equipment with equipment protection level (EPL) Ga IEC60079: Part 27: Fieldbus intrinsically safe concept (FISCO) IEC60079: Part 28: Protection of equipment and transmission systems using optical radiation IEC60079: Part 29-1: Gas detectors - Performance requirements of detectors for flammable gases IEC60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' IEC60079: Part 35-1: Caplights for use in mines susceptible to firedamp - General requirements - Construction and testing in relation to the risk of explosion IEC/TS60079: Part 40: Requirements for process sealing between flammable process fluids and electrical systems IEC/TS60079: Explosive atmospheres - Part 46: Equipment assemblies IEC61241: Part 0: General requirements - Electrical apparatus for use in the presence of combustible dust IEC61241: Part 1: Protection by enclosures 'tD' IEC61241: Part 1-1: Electrical apparatus protected by enclosures and surface temperature limitation - Specification for apparatus IEC62013: Part 1: General requirements - Construction and testing in relation to the risk of explosion - Caplights for use in mines susceptible to firedamp IEC62013: Part 2: Performance and other safety-related matters - Caplights for use in mines susceptible to firedamp ISO80079: Part 36: Non-electrical equipment for explosive atmospheres - Basic method and requirements ISO80079: Part 37: Non-electrical equipment for explosive atmospheres - Non electrical type of protection constructional safety "c", control of ignition source "b", liquid immersion "k" DS2015/001A: IECEx Assessment and Certification of Equipment assemblies |
|||
CANADA | Labtest | LabTest Certification Inc. (LC) | |
Contact
Kavinder
Dhillon
205 - 8291 92 Street +1 604-247-0444 +1 604-247-0442 Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 2: Equipment protection by pressurized enclosures 'p' IEC60079: Part 6: Equipment protection by oil immersion 'o' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 13: Equipment protection by pressurized room "p" and artificially ventilated room "v" IEC60079: Part 15: Equipment protection by type of protection 'n' IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 25: Intrinsically safe electrical systems IEC60079: Part 26: Equipment with equipment protection level (EPL) Ga IEC60079: Part 28: Protection of equipment and transmission systems using optical radiation IEC/IEEE60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' IEC60079: Part 33: Equipment protection by special protection 's' IEC/TS60079: Explosive atmospheres - Part 46: Equipment assemblies ISO80079: Part 36: Non-electrical equipment for explosive atmospheres - Basic method and requirements ISO80079: Part 37: Non-electrical equipment for explosive atmospheres - Non electrical type of protection constructional safety "c", control of ignition source "b", liquid immersion "k" DS2015/001A: IECEx Assessment and Certification of Equipment assemblies |
|||
CANADA | CSA | CSA Group (CSA, CSAE) | |
Contact
Bryn
Spencer
Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 2: Equipment protection by pressurized enclosures 'p' IEC60079: Part 5: Equipment protection by powder filling 'q' IEC60079: Part 6: Equipment protection by oil immersion 'o' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 13: Equipment protection by pressurized room "p" and artificially ventilated room "v" IEC60079: Part 15: Equipment protection by type of protection 'n' IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 25: Intrinsically safe electrical systems IEC60079: Part 26: Equipment with equipment protection level (EPL) Ga IEC60079: Part 27: Fieldbus intrinsically safe concept (FISCO) IEC60079: Part 28: Protection of equipment and transmission systems using optical radiation IEC60079: Part 29-1: Gas detectors - Performance requirements of detectors for flammable gases IEC60079: Part 29-4: Gas detectors - Performance requirements of open path detectors for flammable gases IEC60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC/IEEE60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' IEC/TS60079: Part 40: Requirements for process sealing between flammable process fluids and electrical systems IEC/TS60079: Explosive atmospheres - Part 46: Equipment assemblies IEC/TS60079: Explosive atmospheres – Part 47: Equipment protection by 2-wire intrinsically safe Ethernet concept (2-WISE) IEC61779: Part 1: General requirements and test methods - Electrical apparatus for the detection and measurement of flammable gases IEC61779: Part 4: Performance requirements for group II apparatus indicating a volume fraction up to 100% lower explosive limit IEC61779: Part 5: Performance requirements for group II apparatus indicating a volume fraction up to 100% gas IEC61241: Part 0: General requirements - Electrical apparatus for use in the presence of combustible dust IEC61241: Part 1: Protection by enclosures 'tD' IEC61241: Part 1-1: Electrical apparatus protected by enclosures and surface temperature limitation - Specification for apparatus IEC61241: Part 4: Type of protection 'pD' IEC61241: Part 11: Protection by intrinsic safety 'iD' IEC61241: Part 18: Protection by encapsulation 'mD' ISO80079: Part 36: Non-electrical equipment for explosive atmospheres - Basic method and requirements ISO80079: Part 37: Non-electrical equipment for explosive atmospheres - Non electrical type of protection constructional safety "c", control of ignition source "b", liquid immersion "k" DS2015/001A: IECEx Assessment and Certification of Equipment assemblies |
|||
CROATIA | Fiditas | Fiditas d.o.o. (FIDI & EXA) | |
Contact
Marino
Kelava
Slavka Tomerlina 44 +385 1 5578 565 +385 1 5578 565 Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 2: Equipment protection by pressurized enclosures 'p' IEC60079: Part 5: Equipment protection by powder filling 'q' IEC60079: Part 6: Equipment protection by oil immersion 'o' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 13: Equipment protection by pressurized room "p" and artificially ventilated room "v" IEC60079: Part 15: Equipment protection by type of protection 'n' IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 25: Intrinsically safe electrical systems IEC60079: Part 26: Equipment with equipment protection level (EPL) Ga IEC60079: Part 27: Fieldbus intrinsically safe concept (FISCO) IEC60079: Part 28: Protection of equipment and transmission systems using optical radiation IEC60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC/IEEE60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' **IEC60079: Edition 2.0 Explosive atmospheres - Part 32-2: Electrostatics hazards – Tests ** This Standard may be used for testing purposes but not for issuing an IECEx Certificate of Conformity IEC/TS60079: Explosive atmospheres - Part 46: Equipment assemblies IEC/TS60079: Explosive atmospheres – Part 47: Equipment protection by 2-wire intrinsically safe Ethernet concept (2-WISE) IEC61241: Part 0: General requirements - Electrical apparatus for use in the presence of combustible dust IEC61241: Part 1: Protection by enclosures 'tD' IEC61241: Part 4: Type of protection 'pD' IEC61241: Part 11: Protection by intrinsic safety 'iD' IEC61241: Part 18: Protection by encapsulation 'mD' IEC62784: Vacuum cleaners and dust extractors providing equipment protection level Dc for the collection of combustible dusts - Particular requirements ISO80079: Part 36: Non-electrical equipment for explosive atmospheres - Basic method and requirements ISO80079: Part 37: Non-electrical equipment for explosive atmospheres - Non electrical type of protection constructional safety "c", control of ignition source "b", liquid immersion "k" DS2015/001A: IECEx Assessment and Certification of Equipment assemblies |
|||
CZECH REPUBLIC | FTZU | Fyzikálně technický zkušební ústav,s.p. (Physical Technical Testing Institute) (FTZU) | |
Contact
Lukas
Martinak
+420 595 223 111 Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 2: Equipment protection by pressurized enclosures 'p' IEC60079: Part 5: Equipment protection by powder filling 'q' IEC60079: Part 6: Equipment protection by oil immersion 'o' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 13: Equipment protection by pressurized room "p" and artificially ventilated room "v" IEC60079: Part 15: Equipment protection by type of protection 'n' IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 25: Intrinsically safe electrical systems IEC60079: Part 26: Equipment with equipment protection level (EPL) Ga IEC60079: Part 27: Fieldbus intrinsically safe concept (FISCO) IEC60079: Part 28: Protection of equipment and transmission systems using optical radiation IEC60079: Part 29-1: Gas detectors - Performance requirements of detectors for flammable gases IEC60079: Part 29-4: Gas detectors - Performance requirements of open path detectors for flammable gases IEC60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC/IEEE60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' IEC60079: Part 33: Equipment protection by special protection 's' IEC60079: Part 35-1: Caplights for use in mines susceptible to firedamp - General requirements - Construction and testing in relation to the risk of explosion IEC60079: Part 35-2: Caplights for use in mines susceptible to firedamp - Performance IEC/TS60079: Part 40: Requirements for process sealing between flammable process fluids and electrical systems **IEC/TS60079: Explosive atmospheres- Electrical safety devices for the control of potential ignition sources for Ex-Equipment. ** This TS may be used for testing purposes but not for issuing an IECEx Certificate of Conformity IEC/TS60079: Explosive atmospheres - Part 46: Equipment assemblies IEC/TS60079: Explosive atmospheres – Part 47: Equipment protection by 2-wire intrinsically safe Ethernet concept (2-WISE) IEC61779: Part 1: General requirements and test methods - Electrical apparatus for the detection and measurement of flammable gases IEC61779: Part 2: Performance requirements for group I apparatus indicating a volume fraction up to 5% methane in air IEC61779: Part 3: Performance requirements for group I apparatus indicating a volume fraction up to 100% methane in air IEC61779: Part 4: Performance requirements for group II apparatus indicating a volume fraction up to 100% lower explosive limit IEC61779: Part 5: Performance requirements for group II apparatus indicating a volume fraction up to 100% gas IEC61241: Part 0: General requirements - Electrical apparatus for use in the presence of combustible dust IEC61241: Part 1: Protection by enclosures 'tD' IEC61241: Part 1-1: Electrical apparatus protected by enclosures and surface temperature limitation - Specification for apparatus IEC61241: Part 4: Type of protection 'pD' IEC61241: Part 11: Protection by intrinsic safety 'iD' IEC61241: Part 18: Protection by encapsulation 'mD' IEC62013: Part 1: General requirements - Construction and testing in relation to the risk of explosion - Caplights for use in mines susceptible to firedamp IEC62013: Part 2: Performance and other safety-related matters - Caplights for use in mines susceptible to firedamp IEC62086: Part 1: General and testing requirements - Electrical apparatus for explosive gas atmospheres – Electrical resistance trace heating IEC62784: Vacuum cleaners and dust extractors providing equipment protection level Dc for the collection of combustible dusts - Particular requirements IEC62990: Workplace atmospheres – Part 1: Gas detectors – Performance requirements of detectors for toxic gases ISO80079: Part 36: Non-electrical equipment for explosive atmospheres - Basic method and requirements ISO80079: Part 37: Non-electrical equipment for explosive atmospheres - Non electrical type of protection constructional safety "c", control of ignition source "b", liquid immersion "k" ISO16852: Flame arresters - Performance requirements, test methods and limits for use DS2015/001A: IECEx Assessment and Certification of Equipment assemblies TR60079: Part 16: Artificial ventilation for the protection of analyser(s) houses |
|||
DENMARK | UL/Demko | UL Solutions (Demko) | |
Contact
Jasmin
Omerovic
Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 2: Equipment protection by pressurized enclosures 'p' IEC60079: Part 5: Equipment protection by powder filling 'q' IEC60079: Part 6: Equipment protection by oil immersion 'o' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 13: Equipment protection by pressurized room "p" and artificially ventilated room "v" IEC60079: Part 15: Equipment protection by type of protection 'n' IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 25: Intrinsically safe electrical systems IEC60079: Part 26: Equipment with equipment protection level (EPL) Ga IEC60079: Part 27: Fieldbus intrinsically safe concept (FISCO) IEC60079: Part 28: Protection of equipment and transmission systems using optical radiation IEC60079: Part 29-1: Gas detectors - Performance requirements of detectors for flammable gases IEC60079: Part 29-4: Gas detectors - Performance requirements of open path detectors for flammable gases IEC60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC/IEEE60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' IEC60079: Part 33: Equipment protection by special protection 's' IEC60079: Part 35-1: Caplights for use in mines susceptible to firedamp - General requirements - Construction and testing in relation to the risk of explosion IEC/TS60079: Part 40: Requirements for process sealing between flammable process fluids and electrical systems **IEC/TS60079: Explosive atmospheres- Electrical safety devices for the control of potential ignition sources for Ex-Equipment. ** This TS may be used for testing purposes but not for issuing an IECEx Certificate of Conformity IEC/TS60079: Explosive atmospheres - Part 46: Equipment assemblies IEC/TS60079: Explosive atmospheres – Part 47: Equipment protection by 2-wire intrinsically safe Ethernet concept (2-WISE) IEC61241: Part 0: General requirements - Electrical apparatus for use in the presence of combustible dust IEC61241: Part 1: Protection by enclosures 'tD' IEC61241: Part 1-1: Electrical apparatus protected by enclosures and surface temperature limitation - Specification for apparatus IEC61241: Part 4: Type of protection 'pD' IEC61241: Part 11: Protection by intrinsic safety 'iD' IEC61241: Part 18: Protection by encapsulation 'mD' IEC62086: Part 1: General and testing requirements - Electrical apparatus for explosive gas atmospheres – Electrical resistance trace heating IEC62784: Vacuum cleaners and dust extractors providing equipment protection level Dc for the collection of combustible dusts - Particular requirements ISO80079: Part 36: Non-electrical equipment for explosive atmospheres - Basic method and requirements ISO80079: Part 37: Non-electrical equipment for explosive atmospheres - Non electrical type of protection constructional safety "c", control of ignition source "b", liquid immersion "k" |
|||
FINLAND | EESF | Eurofins Electric & Electronics Finland Oy (EESF) | |
Contact
Jenni
Hirvelä
Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 2: Equipment protection by pressurized enclosures 'p' IEC60079: Part 5: Equipment protection by powder filling 'q' IEC60079: Part 6: Equipment protection by oil immersion 'o' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 15: Equipment protection by type of protection 'n' IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 25: Intrinsically safe electrical systems IEC60079: Part 26: Equipment with equipment protection level (EPL) Ga IEC60079: Part 27: Fieldbus intrinsically safe concept (FISCO) IEC60079: Part 28: Protection of equipment and transmission systems using optical radiation IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' IEC/TS60079: Explosive atmospheres - Part 46: Equipment assemblies IEC61241: Part 0: General requirements - Electrical apparatus for use in the presence of combustible dust IEC61241: Part 1: Protection by enclosures 'tD' IEC61241: Part 1-1: Electrical apparatus protected by enclosures and surface temperature limitation - Specification for apparatus IEC61241: Part 4: Type of protection 'pD' IEC61241: Part 11: Protection by intrinsic safety 'iD' IEC61241: Part 18: Protection by encapsulation 'mD' ISO80079: Part 36: Non-electrical equipment for explosive atmospheres - Basic method and requirements ISO80079: Part 37: Non-electrical equipment for explosive atmospheres - Non electrical type of protection constructional safety "c", control of ignition source "b", liquid immersion "k" DS2015/001A: IECEx Assessment and Certification of Equipment assemblies Notes
|
|||
FRANCE | LCIE | Laboratoire Central des Industries Electriques – Bureau Veritas (LCIE) | |
Contact
Marie-Elisabeth
d'Ornano
Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 2: Equipment protection by pressurized enclosures 'p' IEC60079: Part 5: Equipment protection by powder filling 'q' IEC60079: Part 6: Equipment protection by oil immersion 'o' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 13: Equipment protection by pressurized room "p" and artificially ventilated room "v" IEC60079: Part 15: Equipment protection by type of protection 'n' IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 25: Intrinsically safe electrical systems IEC60079: Part 26: Equipment with equipment protection level (EPL) Ga IEC60079: Part 27: Fieldbus intrinsically safe concept (FISCO) IEC60079: Part 28: Protection of equipment and transmission systems using optical radiation IEC60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' IEC/TS60079: Explosive atmospheres - Part 46: Equipment assemblies IEC61241: Part 0: General requirements - Electrical apparatus for use in the presence of combustible dust IEC61241: Part 1: Protection by enclosures 'tD' IEC61241: Part 1-1: Electrical apparatus protected by enclosures and surface temperature limitation - Specification for apparatus IEC61241: Part 4: Type of protection 'pD' IEC61241: Part 11: Protection by intrinsic safety 'iD' IEC61241: Part 18: Protection by encapsulation 'mD' IEC62086: Part 1: General and testing requirements - Electrical apparatus for explosive gas atmospheres – Electrical resistance trace heating ISO80079: Part 36: Non-electrical equipment for explosive atmospheres - Basic method and requirements ISO80079: Part 37: Non-electrical equipment for explosive atmospheres - Non electrical type of protection constructional safety "c", control of ignition source "b", liquid immersion "k" DS2015/001A: IECEx Assessment and Certification of Equipment assemblies |
|||
FRANCE | INERIS | INERIS - Institut National de l'Environnement Industriel et des Risques (INE) | |
Contact
Thierry
Houeix
BP n°2 / Parc Technologique ALATA +33 (0)3 44 55 64 88 +33 (0)3 44 55 67 04 Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 2: Equipment protection by pressurized enclosures 'p' IEC60079: Part 5: Equipment protection by powder filling 'q' IEC60079: Part 6: Equipment protection by oil immersion 'o' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 13: Equipment protection by pressurized room "p" and artificially ventilated room "v" IEC60079: Part 15: Equipment protection by type of protection 'n' IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 25: Intrinsically safe electrical systems IEC60079: Part 26: Equipment with equipment protection level (EPL) Ga IEC60079: Part 28: Protection of equipment and transmission systems using optical radiation IEC60079: Part 29-1: Gas detectors - Performance requirements of detectors for flammable gases IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' IEC60079: Part 33: Equipment protection by special protection 's' **IEC/TS60079: Explosive atmospheres- Electrical safety devices for the control of potential ignition sources for Ex-Equipment. ** This TS may be used for testing purposes but not for issuing an IECEx Certificate of Conformity IEC/TS60079: Explosive atmospheres - Part 46: Equipment assemblies IEC61241: Part 0: General requirements - Electrical apparatus for use in the presence of combustible dust IEC61241: Part 1: Protection by enclosures 'tD' IEC61241: Part 1-1: Electrical apparatus protected by enclosures and surface temperature limitation - Specification for apparatus IEC61241: Part 4: Type of protection 'pD' IEC61241: Part 11: Protection by intrinsic safety 'iD' IEC61241: Part 18: Protection by encapsulation 'mD' IECExOD 290: IECEx Certified Equipment Scheme - Harmonized procedures for IECEx certification of equipment, components and systems associated with the production, dispensing and use of gaseous hydrogen ISO80079: Part 36: Non-electrical equipment for explosive atmospheres - Basic method and requirements ISO80079: Part 37: Non-electrical equipment for explosive atmospheres - Non electrical type of protection constructional safety "c", control of ignition source "b", liquid immersion "k" DS2015/001A: IECEx Assessment and Certification of Equipment assemblies |
|||
GERMANY | BV | Bureau Veritas Consumer Products Services Germany GmbH (EPS) | |
Contact
Ulrich
Feike
Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 2: Equipment protection by pressurized enclosures 'p' IEC60079: Part 5: Equipment protection by powder filling 'q' IEC60079: Part 6: Equipment protection by oil immersion 'o' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 13: Equipment protection by pressurized room "p" and artificially ventilated room "v" IEC60079: Part 15: Equipment protection by type of protection 'n' IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 25: Intrinsically safe electrical systems IEC60079: Part 26: Equipment with equipment protection level (EPL) Ga IEC60079: Part 27: Fieldbus intrinsically safe concept (FISCO) IEC60079: Part 28: Protection of equipment and transmission systems using optical radiation IEC60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC/IEEE60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' IEC60079: Part 33: Equipment protection by special protection 's' IEC/TS60079: Part 40: Requirements for process sealing between flammable process fluids and electrical systems **IEC/TS60079: Explosive atmospheres- Electrical safety devices for the control of potential ignition sources for Ex-Equipment. ** This TS may be used for testing purposes but not for issuing an IECEx Certificate of Conformity IEC/TS60079: Explosive atmospheres - Part 46: Equipment assemblies IEC/TS60079: Explosive atmospheres – Part 47: Equipment protection by 2-wire intrinsically safe Ethernet concept (2-WISE) IEC61241: Part 0: General requirements - Electrical apparatus for use in the presence of combustible dust IEC61241: Part 1: Protection by enclosures 'tD' IEC61241: Part 1-1: Electrical apparatus protected by enclosures and surface temperature limitation - Specification for apparatus IEC61241: Part 4: Type of protection 'pD' IEC61241: Part 11: Protection by intrinsic safety 'iD' IEC61241: Part 18: Protection by encapsulation 'mD' IEC62086: Part 1: General and testing requirements - Electrical apparatus for explosive gas atmospheres – Electrical resistance trace heating ISO80079: Part 36: Non-electrical equipment for explosive atmospheres - Basic method and requirements ISO80079: Part 37: Non-electrical equipment for explosive atmospheres - Non electrical type of protection constructional safety "c", control of ignition source "b", liquid immersion "k" DS2015/001A: IECEx Assessment and Certification of Equipment assemblies Notes
|
|||
GERMANY | DEKRA EXAM | DEKRA Testing and Certification GmbH (BVS) | |
Contact
Ing Franz
Eickhoff
Carl-Beyling-Haus Postal Address +49.234.3696-334 +49.234.3696-301 Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 2: Equipment protection by pressurized enclosures 'p' IEC60079: Part 5: Equipment protection by powder filling 'q' IEC60079: Part 6: Equipment protection by oil immersion 'o' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 13: Equipment protection by pressurized room "p" and artificially ventilated room "v" IEC60079: Part 15: Equipment protection by type of protection 'n' IEC60079: Part 16: Artificial ventilation for the protection of analyser (s) houses IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 25: Intrinsically safe electrical systems IEC60079: Part 26: Equipment with equipment protection level (EPL) Ga IEC60079: Part 27: Fieldbus intrinsically safe concept (FISCO) IEC60079: Part 28: Protection of equipment and transmission systems using optical radiation IEC60079: Part 29-1: Gas detectors - Performance requirements of detectors for flammable gases IEC60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC/IEEE60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' IEC60079: Part 33: Equipment protection by special protection 's' IEC60079: Part 35-1: Caplights for use in mines susceptible to firedamp - General requirements - Construction and testing in relation to the risk of explosion IEC/TS60079: Part 39: Intrinsically safe systems with electronically controlled spark duration limitation IEC/TS60079: Part 40: Requirements for process sealing between flammable process fluids and electrical systems **IEC/TS60079: Explosive atmospheres- Electrical safety devices for the control of potential ignition sources for Ex-Equipment. ** This TS may be used for testing purposes but not for issuing an IECEx Certificate of Conformity IEC/TS60079: Explosive atmospheres - Part 46: Equipment assemblies IEC/TS60079: Explosive atmospheres – Part 47: Equipment protection by 2-wire intrinsically safe Ethernet concept (2-WISE) IEC61779: Part 1: General requirements and test methods - Electrical apparatus for the detection and measurement of flammable gases IEC61779: Part 2: Performance requirements for group I apparatus indicating a volume fraction up to 5% methane in air IEC61779: Part 3: Performance requirements for group I apparatus indicating a volume fraction up to 100% methane in air IEC61779: Part 4: Performance requirements for group II apparatus indicating a volume fraction up to 100% lower explosive limit IEC61779: Part 5: Performance requirements for group II apparatus indicating a volume fraction up to 100% gas IEC61241: Part 0: General requirements - Electrical apparatus for use in the presence of combustible dust IEC61241: Part 1: Protection by enclosures 'tD' IEC61241: Part 1-1: Electrical apparatus protected by enclosures and surface temperature limitation - Specification for apparatus IEC61241: Part 4: Type of protection 'pD' IEC61241: Part 11: Protection by intrinsic safety 'iD' IEC61241: Part 18: Protection by encapsulation 'mD' IEC62013: Part 1: General requirements - Construction and testing in relation to the risk of explosion - Caplights for use in mines susceptible to firedamp IEC62086: Part 1: General and testing requirements - Electrical apparatus for explosive gas atmospheres – Electrical resistance trace heating IEC62990: Workplace atmospheres – Part 1: Gas detectors – Performance requirements of detectors for toxic gases ISO80079: Part 36: Non-electrical equipment for explosive atmospheres - Basic method and requirements ISO80079: Part 37: Non-electrical equipment for explosive atmospheres - Non electrical type of protection constructional safety "c", control of ignition source "b", liquid immersion "k" DS2015/001A: IECEx Assessment and Certification of Equipment assemblies |
|||
GERMANY | TÜV Rheinland | TÜV Rheinland Industrie Service GmbH (TUR) | |
Contact
Klauspeter
Graffi
Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 2: Equipment protection by pressurized enclosures 'p' IEC60079: Part 5: Equipment protection by powder filling 'q' IEC60079: Part 6: Equipment protection by oil immersion 'o' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 13: Equipment protection by pressurized room "p" and artificially ventilated room "v" IEC60079: Part 15: Equipment protection by type of protection 'n' IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 25: Intrinsically safe electrical systems IEC60079: Part 26: Equipment with equipment protection level (EPL) Ga IEC60079: Part 27: Fieldbus intrinsically safe concept (FISCO) IEC60079: Part 28: Protection of equipment and transmission systems using optical radiation IEC60079: Part 29-1: Gas detectors - Performance requirements of detectors for flammable gases IEC60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC/IEEE60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' IEC60079: Part 33: Equipment protection by special protection 's' IEC60079: Part 35-2: Caplights for use in mines susceptible to firedamp - Performance IEC/TS60079: Explosive atmospheres - Part 46: Equipment assemblies IEC/TS60079: Explosive atmospheres – Part 47: Equipment protection by 2-wire intrinsically safe Ethernet concept (2-WISE) IEC61241: Part 0: General requirements - Electrical apparatus for use in the presence of combustible dust IEC61241: Part 1: Protection by enclosures 'tD' IEC61241: Part 4: Type of protection 'pD' IEC61241: Part 11: Protection by intrinsic safety 'iD' IEC61241: Part 18: Protection by encapsulation 'mD' IEC62990: Workplace atmospheres – Part 1: Gas detectors – Performance requirements of detectors for toxic gases ISO80079: Part 36: Non-electrical equipment for explosive atmospheres - Basic method and requirements ISO80079: Part 37: Non-electrical equipment for explosive atmospheres - Non electrical type of protection constructional safety "c", control of ignition source "b", liquid immersion "k" DS2015/001A: IECEx Assessment and Certification of Equipment assemblies |
|||
GERMANY | TUV NORD | TÜV NORD CERT GmbH (TUN) | |
Contact
Christian
Roder
Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 2: Equipment protection by pressurized enclosures 'p' IEC60079: Part 5: Equipment protection by powder filling 'q' IEC60079: Part 6: Equipment protection by oil immersion 'o' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 15: Equipment protection by type of protection 'n' IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 25: Intrinsically safe electrical systems IEC60079: Part 26: Equipment with equipment protection level (EPL) Ga IEC60079: Part 27: Fieldbus intrinsically safe concept (FISCO) IEC60079: Part 28: Protection of equipment and transmission systems using optical radiation IEC/IEEE60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' IEC/TS60079: Explosive atmospheres - Part 46: Equipment assemblies IEC61241: Part 0: General requirements - Electrical apparatus for use in the presence of combustible dust IEC61241: Part 1: Protection by enclosures 'tD' IEC61241: Part 4: Type of protection 'pD' IEC61241: Part 11: Protection by intrinsic safety 'iD' IEC61241: Part 18: Protection by encapsulation 'mD' ISO80079: Part 36: Non-electrical equipment for explosive atmospheres - Basic method and requirements ISO80079: Part 37: Non-electrical equipment for explosive atmospheres - Non electrical type of protection constructional safety "c", control of ignition source "b", liquid immersion "k" DS2015/001A: IECEx Assessment and Certification of Equipment assemblies |
|||
GERMANY | IBExU | IBExU Institut für Sicherheitstechnik GmbH (IBE) | |
Contact
Kristin
Krumbiegel
Fuchsmühlenweg 7 +49 (0) 37 31 / 38 05 0 + 49 (0) 37 31 / 38 05 10 Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 2: Equipment protection by pressurized enclosures 'p' IEC60079: Part 5: Equipment protection by powder filling 'q' IEC60079: Part 6: Equipment protection by oil immersion 'o' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 15: Equipment protection by type of protection 'n' IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 25: Intrinsically safe electrical systems IEC60079: Part 26: Equipment with equipment protection level (EPL) Ga IEC60079: Part 27: Fieldbus intrinsically safe concept (FISCO) IEC60079: Part 28: Protection of equipment and transmission systems using optical radiation IEC60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC/IEEE60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' IEC60079: Part 35-1: Caplights for use in mines susceptible to firedamp - General requirements - Construction and testing in relation to the risk of explosion IEC61241: Part 0: General requirements - Electrical apparatus for use in the presence of combustible dust IEC61241: Part 1: Protection by enclosures 'tD' IEC61241: Part 1-1: Electrical apparatus protected by enclosures and surface temperature limitation - Specification for apparatus IEC61241: Part 4: Type of protection 'pD' IEC61241: Part 11: Protection by intrinsic safety 'iD' IEC61241: Part 18: Protection by encapsulation 'mD' IEC62013: Part 1: General requirements - Construction and testing in relation to the risk of explosion - Caplights for use in mines susceptible to firedamp IEC62086: Part 1: General and testing requirements - Electrical apparatus for explosive gas atmospheres – Electrical resistance trace heating IEC62784: Vacuum cleaners and dust extractors providing equipment protection level Dc for the collection of combustible dusts - Particular requirements ISO/IEC80079: Explosive atmospheres - Part 49: Flame arresters - Performance requirements, test methods and limits of use ISO80079: Part 36: Non-electrical equipment for explosive atmospheres - Basic method and requirements ISO80079: Part 37: Non-electrical equipment for explosive atmospheres - Non electrical type of protection constructional safety "c", control of ignition source "b", liquid immersion "k" ISO16852: Flame arresters - Performance requirements, test methods and limits for use |
|||
GERMANY | PTB | Physikalisch-Technische Bundesanstalt (PTB) | |
Contact
Martin
Thedens
Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 2: Equipment protection by pressurized enclosures 'p' IEC60079: Part 5: Equipment protection by powder filling 'q' IEC60079: Part 6: Equipment protection by oil immersion 'o' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 15: Equipment protection by type of protection 'n' IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 25: Intrinsically safe electrical systems IEC60079: Part 26: Equipment with equipment protection level (EPL) Ga IEC60079: Part 27: Fieldbus intrinsically safe concept (FISCO) IEC60079: Part 28: Protection of equipment and transmission systems using optical radiation IEC60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC/IEEE60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' IEC60079: Part 33: Equipment protection by special protection 's' **IEC/TS60079: Explosive atmospheres- Electrical safety devices for the control of potential ignition sources for Ex-Equipment. ** This TS may be used for testing purposes but not for issuing an IECEx Certificate of Conformity IEC/TS60079: Explosive atmospheres - Part 46: Equipment assemblies IEC61241: Part 0: General requirements - Electrical apparatus for use in the presence of combustible dust IEC61241: Part 1: Protection by enclosures 'tD' IEC61241: Part 1-1: Electrical apparatus protected by enclosures and surface temperature limitation - Specification for apparatus IEC61241: Part 4: Type of protection 'pD' IEC61241: Part 11: Protection by intrinsic safety 'iD' IEC61241: Part 18: Protection by encapsulation 'mD' IEC62086: Part 1: General and testing requirements - Electrical apparatus for explosive gas atmospheres – Electrical resistance trace heating ISO80079: Part 36: Non-electrical equipment for explosive atmospheres - Basic method and requirements ISO80079: Part 37: Non-electrical equipment for explosive atmospheres - Non electrical type of protection constructional safety "c", control of ignition source "b", liquid immersion "k" ISO16852: Flame arresters - Performance requirements, test methods and limits for use |
|||
GERMANY | TUV SUD PS | TÜV SÜD Product Service GmbH (TPS) | |
Contact
Klaus
Lorenz
Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 2: Equipment protection by pressurized enclosures 'p' IEC60079: Part 5: Equipment protection by powder filling 'q' IEC60079: Part 6: Equipment protection by oil immersion 'o' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 13: Equipment protection by pressurized room "p" and artificially ventilated room "v" IEC60079: Part 15: Equipment protection by type of protection 'n' IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 25: Intrinsically safe electrical systems IEC60079: Part 26: Equipment with equipment protection level (EPL) Ga IEC60079: Part 28: Protection of equipment and transmission systems using optical radiation IEC/IEEE60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' IEC60079: Part 35-1: Caplights for use in mines susceptible to firedamp - General requirements - Construction and testing in relation to the risk of explosion IEC/TS60079: Explosive atmospheres - Part 46: Equipment assemblies IEC/TS60079: Explosive atmospheres – Part 47: Equipment protection by 2-wire intrinsically safe Ethernet concept (2-WISE) IEC61241: Part 0: General requirements - Electrical apparatus for use in the presence of combustible dust IEC61241: Part 1: Protection by enclosures 'tD' IEC61241: Part 1-1: Electrical apparatus protected by enclosures and surface temperature limitation - Specification for apparatus IEC61241: Part 4: Type of protection 'pD' IEC61241: Part 11: Protection by intrinsic safety 'iD' IEC61241: Part 18: Protection by encapsulation 'mD' ISO80079: Part 36: Non-electrical equipment for explosive atmospheres - Basic method and requirements ISO80079: Part 37: Non-electrical equipment for explosive atmospheres - Non electrical type of protection constructional safety "c", control of ignition source "b", liquid immersion "k" DS2015/001A: IECEx Assessment and Certification of Equipment assemblies TR60079: Part 16: Artificial ventilation for the protection of analyser(s) houses |
|||
GREECE | KR Hellas Ltd | KR Hellas Ltd, (KRH) | |
Contact
Nikos
Katiforis
Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 2: Equipment protection by pressurized enclosures 'p' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 15: Equipment protection by type of protection 'n' IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 26: Equipment with equipment protection level (EPL) Ga IEC60079: Part 28: Protection of equipment and transmission systems using optical radiation IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' |
|||
HUNGARY | BKI | ExVA Ltd (BKI) | |
Contact
Nagy
Botond
Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 2: Equipment protection by pressurized enclosures 'p' IEC60079: Part 5: Equipment protection by powder filling 'q' IEC60079: Part 6: Equipment protection by oil immersion 'o' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 15: Equipment protection by type of protection 'n' IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 26: Equipment with equipment protection level (EPL) Ga IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' IEC61779: Part 1: General requirements and test methods - Electrical apparatus for the detection and measurement of flammable gases IEC61779: Part 2: Performance requirements for group I apparatus indicating a volume fraction up to 5% methane in air IEC61779: Part 3: Performance requirements for group I apparatus indicating a volume fraction up to 100% methane in air IEC61779: Part 4: Performance requirements for group II apparatus indicating a volume fraction up to 100% lower explosive limit IEC61779: Part 5: Performance requirements for group II apparatus indicating a volume fraction up to 100% gas IEC61241: Part 0: General requirements - Electrical apparatus for use in the presence of combustible dust IEC61241: Part 1: Protection by enclosures 'tD' IEC61241: Part 1-1: Electrical apparatus protected by enclosures and surface temperature limitation - Specification for apparatus IEC61241: Part 4: Type of protection 'pD' IEC61241: Part 11: Protection by intrinsic safety 'iD' IEC61241: Part 18: Protection by encapsulation 'mD' DS2015/001A: IECEx Assessment and Certification of Equipment assemblies |
|||
INDIA | KLCS | KL Certification Services (A division of Karandikar Laboratories Pvt. Ltd.) (KLCS) | |
Contact
Ravi
Paranjpe
Gat No. 142, Boisar Chillar Rd., +91 2525 284931 Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 2: Equipment protection by pressurized enclosures 'p' IEC60079: Part 5: Equipment protection by powder filling 'q' IEC60079: Part 6: Equipment protection by oil immersion 'o' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 13: Equipment protection by pressurized room "p" and artificially ventilated room "v" IEC60079: Part 15: Equipment protection by type of protection 'n' IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 25: Intrinsically safe electrical systems IEC60079: Part 26: Equipment with equipment protection level (EPL) Ga IEC60079: Part 28: Protection of equipment and transmission systems using optical radiation IEC60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC/IEEE60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' IEC60079: Part 33: Equipment protection by special protection 's' IEC/TS60079: Explosive atmospheres - Part 46: Equipment assemblies ISO80079: Part 36: Non-electrical equipment for explosive atmospheres - Basic method and requirements ISO80079: Part 37: Non-electrical equipment for explosive atmospheres - Non electrical type of protection constructional safety "c", control of ignition source "b", liquid immersion "k" ISO16852: Flame arresters - Performance requirements, test methods and limits for use Notes
Note: IEC 60079-28 is limited to clause 5.2.2.2 and 5.2.2.3. of 5.2 (“op is”).
|
|||
ISLAMIC REPUBLIC OF IRAN | EPIL | Energy and Power Industries Laboratories Co. (EPIL) | |
Contact
Seyed
Mohsen Mirsadri
Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 28: Protection of equipment and transmission systems using optical radiation IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' |
|||
ISRAEL | ITL | I.T.L (Product Testing) LTD | |
Contact
Ilan
Cohen
Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 2: Equipment protection by pressurized enclosures 'p' IEC60079: Part 5: Equipment protection by powder filling 'q' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 15: Equipment protection by type of protection 'n' IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 26: Equipment with equipment protection level (EPL) Ga ISO80079: Part 36: Non-electrical equipment for explosive atmospheres - Basic method and requirements ISO80079: Part 37: Non-electrical equipment for explosive atmospheres - Non electrical type of protection constructional safety "c", control of ignition source "b", liquid immersion "k" Notes
Note: For IEC 60079-1 IEC 60079-2 IEC 60079-5 and IEC 60079-7 ITL use OBAC as the associated ExTL. |
|||
ITALY | EUROFINS | Eurofins Product Testing Italy Srl.(EUT) | |
Contact
Dionisio
Bucchieri
Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 2: Equipment protection by pressurized enclosures 'p' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 15: Equipment protection by type of protection 'n' IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 25: Intrinsically safe electrical systems IEC60079: Part 26: Equipment with equipment protection level (EPL) Ga IEC60079: Part 28: Protection of equipment and transmission systems using optical radiation IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' IEC/TS60079: Explosive atmospheres - Part 46: Equipment assemblies ISO80079: Part 36: Non-electrical equipment for explosive atmospheres - Basic method and requirements ISO80079: Part 37: Non-electrical equipment for explosive atmospheres - Non electrical type of protection constructional safety "c", control of ignition source "b", liquid immersion "k" |
|||
ITALY | CESI | CESI – Centro Elettrotecnico Sperimentale Italiano S.p.A. | |
Contact
Alessandro
Fedato
+39 0221251 Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 2: Equipment protection by pressurized enclosures 'p' IEC60079: Part 5: Equipment protection by powder filling 'q' IEC60079: Part 6: Equipment protection by oil immersion 'o' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 13: Equipment protection by pressurized room "p" and artificially ventilated room "v" IEC60079: Part 15: Equipment protection by type of protection 'n' IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 25: Intrinsically safe electrical systems IEC60079: Part 26: Equipment with equipment protection level (EPL) Ga IEC60079: Part 27: Fieldbus intrinsically safe concept (FISCO) IEC60079: Part 28: Protection of equipment and transmission systems using optical radiation IEC60079: Part 29-1: Gas detectors - Performance requirements of detectors for flammable gases IEC60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC/IEEE60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' IEC/TS60079: Explosive atmospheres - Part 46: Equipment assemblies IEC/TS60079: Explosive atmospheres – Part 47: Equipment protection by 2-wire intrinsically safe Ethernet concept (2-WISE) IEC61241: Part 0: General requirements - Electrical apparatus for use in the presence of combustible dust IEC61241: Part 1: Protection by enclosures 'tD' IEC61241: Part 1-1: Electrical apparatus protected by enclosures and surface temperature limitation - Specification for apparatus IEC61241: Part 4: Type of protection 'pD' IEC61241: Part 11: Protection by intrinsic safety 'iD' IEC61241: Part 18: Protection by encapsulation 'mD' ISO80079: Part 36: Non-electrical equipment for explosive atmospheres - Basic method and requirements ISO80079: Part 37: Non-electrical equipment for explosive atmospheres - Non electrical type of protection constructional safety "c", control of ignition source "b", liquid immersion "k" DS2015/001A: IECEx Assessment and Certification of Equipment assemblies TR60079: Part 16: Artificial ventilation for the protection of analyser(s) houses |
|||
ITALY | IMQ | IMQ S.p.A. - Istituto Italiano del Marchio di Qualità | |
Contact
Mauro
Casari
Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 5: Equipment protection by powder filling 'q' IEC60079: Part 6: Equipment protection by oil immersion 'o' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 15: Equipment protection by type of protection 'n' IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 25: Intrinsically safe electrical systems IEC60079: Part 26: Equipment with equipment protection level (EPL) Ga IEC60079: Part 28: Protection of equipment and transmission systems using optical radiation IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' **IEC/TS60079: Explosive atmospheres- Electrical safety devices for the control of potential ignition sources for Ex-Equipment. ** This TS may be used for testing purposes but not for issuing an IECEx Certificate of Conformity IEC/TS60079: Explosive atmospheres - Part 46: Equipment assemblies IEC61241: Part 0: General requirements - Electrical apparatus for use in the presence of combustible dust IEC61241: Part 11: Protection by intrinsic safety 'iD' ISO80079: Part 36: Non-electrical equipment for explosive atmospheres - Basic method and requirements ISO80079: Part 37: Non-electrical equipment for explosive atmospheres - Non electrical type of protection constructional safety "c", control of ignition source "b", liquid immersion "k" DS2015/001A: IECEx Assessment and Certification of Equipment assemblies |
|||
JAPAN | TIIS | Technology Institution of Industrial Safety (TIIS) | |
Contact
Minari
Kogane
Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 2: Equipment protection by pressurized enclosures 'p' IEC60079: Part 5: Equipment protection by powder filling 'q' IEC60079: Part 6: Equipment protection by oil immersion 'o' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 13: Equipment protection by pressurized room "p" and artificially ventilated room "v" IEC60079: Part 15: Equipment protection by type of protection 'n' IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 25: Intrinsically safe electrical systems IEC60079: Part 26: Equipment with equipment protection level (EPL) Ga IEC60079: Part 28: Protection of equipment and transmission systems using optical radiation IEC60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC/IEEE60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' IEC60079: Part 33: Equipment protection by special protection 's' IEC/TS60079: Explosive atmospheres - Part 46: Equipment assemblies IEC62784: Vacuum cleaners and dust extractors providing equipment protection level Dc for the collection of combustible dusts - Particular requirements ISO80079: Part 36: Non-electrical equipment for explosive atmospheres - Basic method and requirements ISO80079: Part 37: Non-electrical equipment for explosive atmospheres - Non electrical type of protection constructional safety "c", control of ignition source "b", liquid immersion "k" Notes
|
|||
MALAYSIA | SIRIM | SIRIM QAS International SDN BHD (SRM) | |
Contact
Ariza
Mohd Yusof
Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 2: Equipment protection by pressurized enclosures 'p' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 13: Equipment protection by pressurized room "p" and artificially ventilated room "v" IEC60079: Part 15: Equipment protection by type of protection 'n' IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 25: Intrinsically safe electrical systems IEC/TS60079: Explosive atmospheres - Part 46: Equipment assemblies ISO80079: Part 36: Non-electrical equipment for explosive atmospheres - Basic method and requirements ISO80079: Part 37: Non-electrical equipment for explosive atmospheres - Non electrical type of protection constructional safety "c", control of ignition source "b", liquid immersion "k" |
|||
NETHERLANDS | CNEX | CNEX-Global B.V. | |
Contact
Fred
Lankamp
Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 2: Equipment protection by pressurized enclosures 'p' IEC60079: Part 5: Equipment protection by powder filling 'q' IEC60079: Part 6: Equipment protection by oil immersion 'o' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 13: Equipment protection by pressurized room "p" and artificially ventilated room "v" IEC60079: Part 15: Equipment protection by type of protection 'n' IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 25: Intrinsically safe electrical systems IEC60079: Part 26: Equipment with equipment protection level (EPL) Ga IEC60079: Part 27: Fieldbus intrinsically safe concept (FISCO) IEC60079: Part 28: Protection of equipment and transmission systems using optical radiation IEC60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' IEC60079: Part 33: Equipment protection by special protection 's' IEC/TS60079: Explosive atmospheres - Part 46: Equipment assemblies IEC61241: Part 0: General requirements - Electrical apparatus for use in the presence of combustible dust IEC61241: Part 1: Protection by enclosures 'tD' IEC61241: Part 4: Type of protection 'pD' IEC61241: Part 11: Protection by intrinsic safety 'iD' IEC61241: Part 18: Protection by encapsulation 'mD' IEC62086: Part 1: General and testing requirements - Electrical apparatus for explosive gas atmospheres – Electrical resistance trace heating ISO80079: Part 36: Non-electrical equipment for explosive atmospheres - Basic method and requirements ISO80079: Part 37: Non-electrical equipment for explosive atmospheres - Non electrical type of protection constructional safety "c", control of ignition source "b", liquid immersion "k" TR60079: Part 16: Artificial ventilation for the protection of analyser(s) houses |
|||
NETHERLANDS | DEKRA KEMA | DEKRA Certification B.V. (DEK, KEM) | |
Contact
Richard
Schuller
DEKRA Certification B.V. Postal Address +31 88 9683842 +31 88 9683100 Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 2: Equipment protection by pressurized enclosures 'p' IEC60079: Part 5: Equipment protection by powder filling 'q' IEC60079: Part 6: Equipment protection by oil immersion 'o' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 13: Equipment protection by pressurized room "p" and artificially ventilated room "v" IEC60079: Part 15: Equipment protection by type of protection 'n' IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 25: Intrinsically safe electrical systems IEC60079: Part 26: Equipment with equipment protection level (EPL) Ga IEC60079: Part 27: Fieldbus intrinsically safe concept (FISCO) IEC60079: Part 28: Protection of equipment and transmission systems using optical radiation IEC60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC/IEEE60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' IEC60079: Part 33: Equipment protection by special protection 's' IEC60079: Part 35-1: Caplights for use in mines susceptible to firedamp - General requirements - Construction and testing in relation to the risk of explosion IEC/TS60079: Part 40: Requirements for process sealing between flammable process fluids and electrical systems IEC/TS60079: Explosive atmospheres - Part 46: Equipment assemblies IEC/TS60079: Explosive atmospheres – Part 47: Equipment protection by 2-wire intrinsically safe Ethernet concept (2-WISE) IEC61241: Part 0: General requirements - Electrical apparatus for use in the presence of combustible dust IEC61241: Part 1: Protection by enclosures 'tD' IEC61241: Part 1-1: Electrical apparatus protected by enclosures and surface temperature limitation - Specification for apparatus IEC61241: Part 4: Type of protection 'pD' IEC61241: Part 11: Protection by intrinsic safety 'iD' IEC61241: Part 18: Protection by encapsulation 'mD' IEC62013: Part 1: General requirements - Construction and testing in relation to the risk of explosion - Caplights for use in mines susceptible to firedamp IEC62086: Part 1: General and testing requirements - Electrical apparatus for explosive gas atmospheres – Electrical resistance trace heating ISO80079: Part 36: Non-electrical equipment for explosive atmospheres - Basic method and requirements ISO80079: Part 37: Non-electrical equipment for explosive atmospheres - Non electrical type of protection constructional safety "c", control of ignition source "b", liquid immersion "k" DS2015/001A: IECEx Assessment and Certification of Equipment assemblies |
|||
NORWAY | Presafe/DNV | DNV Product Assurance AS (PRE, DNV, NEM) | |
Contact
Ståle
Sandstad
Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 2: Equipment protection by pressurized enclosures 'p' IEC60079: Part 5: Equipment protection by powder filling 'q' IEC60079: Part 6: Equipment protection by oil immersion 'o' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 13: Equipment protection by pressurized room "p" and artificially ventilated room "v" IEC60079: Part 15: Equipment protection by type of protection 'n' IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 25: Intrinsically safe electrical systems IEC60079: Part 26: Equipment with equipment protection level (EPL) Ga IEC60079: Part 27: Fieldbus intrinsically safe concept (FISCO) IEC60079: Part 28: Protection of equipment and transmission systems using optical radiation IEC60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' IEC60079: Part 35-1: Caplights for use in mines susceptible to firedamp - General requirements - Construction and testing in relation to the risk of explosion IEC/TS60079: Explosive atmospheres - Part 46: Equipment assemblies IEC61241: Part 0: General requirements - Electrical apparatus for use in the presence of combustible dust IEC61241: Part 1: Protection by enclosures 'tD' IEC61241: Part 4: Type of protection 'pD' IEC61241: Part 11: Protection by intrinsic safety 'iD' IEC61241: Part 18: Protection by encapsulation 'mD' IEC62013: Part 1: General requirements - Construction and testing in relation to the risk of explosion - Caplights for use in mines susceptible to firedamp ISO80079: Part 36: Non-electrical equipment for explosive atmospheres - Basic method and requirements ISO80079: Part 37: Non-electrical equipment for explosive atmospheres - Non electrical type of protection constructional safety "c", control of ignition source "b", liquid immersion "k" DS2015/001A: IECEx Assessment and Certification of Equipment assemblies |
|||
PEOPLES REPUBLIC OF CHINA | NEPSI | Shanghai Inspection and Testing Institute of Instruments and Automatic Systems Co., Ltd. (SITIIAS)/ National Supervision and Inspection Centre for Explosion Protection and Safety of Instrumentation (NEPSI) | |
Contact
Jianping
Xu
Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 2: Equipment protection by pressurized enclosures 'p' IEC60079: Part 5: Equipment protection by powder filling 'q' IEC60079: Part 6: Equipment protection by oil immersion 'o' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 13: Equipment protection by pressurized room "p" and artificially ventilated room "v" IEC60079: Part 15: Equipment protection by type of protection 'n' IEC60079: Part 16: Artificial ventilation for the protection of analyser (s) houses IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 25: Intrinsically safe electrical systems IEC60079: Part 26: Equipment with equipment protection level (EPL) Ga IEC60079: Part 27: Fieldbus intrinsically safe concept (FISCO) IEC60079: Part 28: Protection of equipment and transmission systems using optical radiation IEC60079: Part 29-1: Gas detectors - Performance requirements of detectors for flammable gases IEC60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' IEC60079: Part 33: Equipment protection by special protection 's' IEC/TS60079: Explosive atmospheres - Part 46: Equipment assemblies IEC/TS60079: Explosive atmospheres – Part 47: Equipment protection by 2-wire intrinsically safe Ethernet concept (2-WISE) IEC61241: Part 0: General requirements - Electrical apparatus for use in the presence of combustible dust IEC61241: Part 1: Protection by enclosures 'tD' IEC61241: Part 4: Type of protection 'pD' IEC61241: Part 11: Protection by intrinsic safety 'iD' IEC61241: Part 18: Protection by encapsulation 'mD' IEC62086: Part 1: General and testing requirements - Electrical apparatus for explosive gas atmospheres – Electrical resistance trace heating IEC62784: Vacuum cleaners and dust extractors providing equipment protection level Dc for the collection of combustible dusts - Particular requirements ISO80079: Part 36: Non-electrical equipment for explosive atmospheres - Basic method and requirements ISO80079: Part 37: Non-electrical equipment for explosive atmospheres - Non electrical type of protection constructional safety "c", control of ignition source "b", liquid immersion "k" |
|||
PEOPLES REPUBLIC OF CHINA | CNE | Nanyang Explosion Protected Electrical Apparatus Research Institute Co Ltd (CNE) | |
Contact
Wang
Jun
Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 2: Equipment protection by pressurized enclosures 'p' IEC60079: Part 5: Equipment protection by powder filling 'q' IEC60079: Part 6: Equipment protection by oil immersion 'o' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 13: Equipment protection by pressurized room "p" and artificially ventilated room "v" IEC60079: Part 15: Equipment protection by type of protection 'n' IEC60079: Part 16: Artificial ventilation for the protection of analyser (s) houses IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 25: Intrinsically safe electrical systems IEC60079: Part 26: Equipment with equipment protection level (EPL) Ga IEC60079: Part 27: Fieldbus intrinsically safe concept (FISCO) IEC60079: Part 28: Protection of equipment and transmission systems using optical radiation IEC60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC/IEEE60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' IEC60079: Part 33: Equipment protection by special protection 's' IEC/TS60079: Explosive atmospheres - Part 46: Equipment assemblies IEC61241: Part 0: General requirements - Electrical apparatus for use in the presence of combustible dust IEC61241: Part 1: Protection by enclosures 'tD' IEC61241: Part 4: Type of protection 'pD' IEC61241: Part 11: Protection by intrinsic safety 'iD' IEC61241: Part 18: Protection by encapsulation 'mD' IEC62086: Part 1: General and testing requirements - Electrical apparatus for explosive gas atmospheres – Electrical resistance trace heating ISO80079: Part 36: Non-electrical equipment for explosive atmospheres - Basic method and requirements ISO80079: Part 37: Non-electrical equipment for explosive atmospheres - Non electrical type of protection constructional safety "c", control of ignition source "b", liquid immersion "k" DS2015/001A: IECEx Assessment and Certification of Equipment assemblies Notes
|
|||
PEOPLES REPUBLIC OF CHINA | PCEC | PCEC (Tianjin) Certification Services Co., Ltd. (PCEC) | |
Contact
Mu
Yuqiang
+86-22-26689240-8205 Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 2: Equipment protection by pressurized enclosures 'p' IEC60079: Part 5: Equipment protection by powder filling 'q' IEC60079: Part 6: Equipment protection by oil immersion 'o' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 13: Equipment protection by pressurized room "p" and artificially ventilated room "v" IEC60079: Part 15: Equipment protection by type of protection 'n' IEC60079: Part 16: Artificial ventilation for the protection of analyser (s) houses IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 25: Intrinsically safe electrical systems IEC60079: Part 26: Equipment with equipment protection level (EPL) Ga IEC60079: Part 27: Fieldbus intrinsically safe concept (FISCO) IEC60079: Part 28: Protection of equipment and transmission systems using optical radiation IEC/IEEE60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' IEC60079: Part 33: Equipment protection by special protection 's' IEC61241: Part 1: Protection by enclosures 'tD' IEC61241: Part 4: Type of protection 'pD' IEC61241: Part 11: Protection by intrinsic safety 'iD' ISO80079: Part 36: Non-electrical equipment for explosive atmospheres - Basic method and requirements ISO80079: Part 37: Non-electrical equipment for explosive atmospheres - Non electrical type of protection constructional safety "c", control of ignition source "b", liquid immersion "k" |
|||
PEOPLES REPUBLIC OF CHINA | CQM | China Quality Mark Certification Group Co. Ltd (CQM) | |
Contact
Lu
Qiao
+86 21 52891711 Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 2: Equipment protection by pressurized enclosures 'p' IEC60079: Part 5: Equipment protection by powder filling 'q' IEC60079: Part 6: Equipment protection by oil immersion 'o' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 13: Equipment protection by pressurized room "p" and artificially ventilated room "v" IEC60079: Part 15: Equipment protection by type of protection 'n' IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 25: Intrinsically safe electrical systems IEC60079: Part 26: Equipment with equipment protection level (EPL) Ga IEC60079: Part 27: Fieldbus intrinsically safe concept (FISCO) IEC60079: Part 28: Protection of equipment and transmission systems using optical radiation IEC60079: Part 29-1: Gas detectors - Performance requirements of detectors for flammable gases IEC60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC/IEEE60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' IEC60079: Part 33: Equipment protection by special protection 's' IEC/TS60079: Explosive atmospheres - Part 46: Equipment assemblies IEC61241: Part 0: General requirements - Electrical apparatus for use in the presence of combustible dust IEC61241: Part 1: Protection by enclosures 'tD' IEC61241: Part 1-1: Electrical apparatus protected by enclosures and surface temperature limitation - Specification for apparatus IEC61241: Part 4: Type of protection 'pD' IEC61241: Part 11: Protection by intrinsic safety 'iD' IEC61241: Part 18: Protection by encapsulation 'mD' IEC62086: Part 1: General and testing requirements - Electrical apparatus for explosive gas atmospheres – Electrical resistance trace heating IEC62784: Vacuum cleaners and dust extractors providing equipment protection level Dc for the collection of combustible dusts - Particular requirements ISO80079: Part 36: Non-electrical equipment for explosive atmospheres - Basic method and requirements ISO80079: Part 37: Non-electrical equipment for explosive atmospheres - Non electrical type of protection constructional safety "c", control of ignition source "b", liquid immersion "k" DS2015/001A: IECEx Assessment and Certification of Equipment assemblies TR60079: Part 16: Artificial ventilation for the protection of analyser(s) houses Notes
|
|||
PEOPLES REPUBLIC OF CHINA | CQC | China Quality Certification Center | |
Contact
Bian
Jing
Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 2: Equipment protection by pressurized enclosures 'p' IEC60079: Part 5: Equipment protection by powder filling 'q' IEC60079: Part 6: Equipment protection by oil immersion 'o' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 13: Equipment protection by pressurized room "p" and artificially ventilated room "v" IEC60079: Part 15: Equipment protection by type of protection 'n' IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 25: Intrinsically safe electrical systems IEC60079: Part 26: Equipment with equipment protection level (EPL) Ga IEC60079: Part 28: Protection of equipment and transmission systems using optical radiation IEC60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' IEC61241: Part 0: General requirements - Electrical apparatus for use in the presence of combustible dust IEC61241: Part 1: Protection by enclosures 'tD' IEC61241: Part 4: Type of protection 'pD' IEC61241: Part 11: Protection by intrinsic safety 'iD' IEC61241: Part 18: Protection by encapsulation 'mD' |
|||
PEOPLES REPUBLIC OF CHINA | CMAC | China Mining Products Safety Approval and Certification Center | |
Contact
Li
Bo
008610 84264542 Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 25: Intrinsically safe electrical systems IEC60079: Part 26: Equipment with equipment protection level (EPL) Ga IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' |
|||
POLAND | OBAC | Osrodek Badan, Atestacji i Certyfikacji OBAC Sp. z o.o. | |
Contact
Piotr
Tarnawski
Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 2: Equipment protection by pressurized enclosures 'p' IEC60079: Part 5: Equipment protection by powder filling 'q' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 15: Equipment protection by type of protection 'n' IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 25: Intrinsically safe electrical systems IEC60079: Part 26: Equipment with equipment protection level (EPL) Ga IEC60079: Part 28: Protection of equipment and transmission systems using optical radiation IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' IEC/TS60079: Explosive atmospheres - Part 46: Equipment assemblies IEC61241: Part 4: Type of protection 'pD' ISO80079: Part 36: Non-electrical equipment for explosive atmospheres - Basic method and requirements ISO80079: Part 37: Non-electrical equipment for explosive atmospheres - Non electrical type of protection constructional safety "c", control of ignition source "b", liquid immersion "k" Notes
|
|||
POLAND | ICR | ICR Polska Sp. z o.o. | |
Contact
Jaroslaw
Zadrozny
Plac Przymierza, 6 Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' |
|||
POLAND | GIG | Central Mining Institute for Central Mining Institute - National Research Institute | |
Contact
Piotr
Madej
Glówny Instytut Górnictwa (GIG) Postal Address +48 32 3246 552 +48 32 32 24 931 Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 2: Equipment protection by pressurized enclosures 'p' IEC60079: Part 5: Equipment protection by powder filling 'q' IEC60079: Part 6: Equipment protection by oil immersion 'o' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 13: Equipment protection by pressurized room "p" and artificially ventilated room "v" IEC60079: Part 15: Equipment protection by type of protection 'n' IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 25: Intrinsically safe electrical systems IEC60079: Part 26: Equipment with equipment protection level (EPL) Ga IEC60079: Part 27: Fieldbus intrinsically safe concept (FISCO) IEC60079: Part 28: Protection of equipment and transmission systems using optical radiation IEC60079: Part 29-1: Gas detectors - Performance requirements of detectors for flammable gases IEC60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' IEC60079: Part 35-1: Caplights for use in mines susceptible to firedamp - General requirements - Construction and testing in relation to the risk of explosion IEC/TS60079: Explosive atmospheres - Part 46: Equipment assemblies IEC61241: Part 0: General requirements - Electrical apparatus for use in the presence of combustible dust IEC61241: Part 4: Type of protection 'pD' IEC61241: Part 11: Protection by intrinsic safety 'iD' IEC61241: Part 18: Protection by encapsulation 'mD' IEC62013: Part 1: General requirements - Construction and testing in relation to the risk of explosion - Caplights for use in mines susceptible to firedamp IEC62086: Part 1: General and testing requirements - Electrical apparatus for explosive gas atmospheres – Electrical resistance trace heating ISO/IEC80079: Explosive atmospheres - Part 49: Flame arresters - Performance requirements, test methods and limits of use ISO80079: Part 36: Non-electrical equipment for explosive atmospheres - Basic method and requirements ISO80079: Part 37: Non-electrical equipment for explosive atmospheres - Non electrical type of protection constructional safety "c", control of ignition source "b", liquid immersion "k" ISO16852: Flame arresters - Performance requirements, test methods and limits for use |
|||
POLAND | Hamilton | J.S. Hamilton Poland Sp. z o.o. (JSH) | |
Contact
Damian
Wróbel
ul. Wyzwolenia 14 Postal Address +48 32 730 82 00 Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 2: Equipment protection by pressurized enclosures 'p' IEC60079: Part 6: Equipment protection by oil immersion 'o' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 15: Equipment protection by type of protection 'n' IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 25: Intrinsically safe electrical systems IEC60079: Part 26: Equipment with equipment protection level (EPL) Ga IEC60079: Part 28: Protection of equipment and transmission systems using optical radiation IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' IEC/TS60079: Explosive atmospheres - Part 46: Equipment assemblies ISO80079: Part 36: Non-electrical equipment for explosive atmospheres - Basic method and requirements ISO80079: Part 37: Non-electrical equipment for explosive atmospheres - Non electrical type of protection constructional safety "c", control of ignition source "b", liquid immersion "k" |
|||
POLAND | KSCP | KSC POLAND Sp. z o.o. | |
Contact
Sanghe
Kim
Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 2: Equipment protection by pressurized enclosures 'p' IEC60079: Part 5: Equipment protection by powder filling 'q' IEC60079: Part 6: Equipment protection by oil immersion 'o' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 13: Equipment protection by pressurized room "p" and artificially ventilated room "v" IEC60079: Part 15: Equipment protection by type of protection 'n' IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 25: Intrinsically safe electrical systems IEC60079: Part 26: Equipment with equipment protection level (EPL) Ga IEC60079: Part 28: Protection of equipment and transmission systems using optical radiation IEC60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' IEC60079: Part 33: Equipment protection by special protection 's' IEC/TS60079: Explosive atmospheres - Part 46: Equipment assemblies ISO80079: Part 36: Non-electrical equipment for explosive atmospheres - Basic method and requirements ISO80079: Part 37: Non-electrical equipment for explosive atmospheres - Non electrical type of protection constructional safety "c", control of ignition source "b", liquid immersion "k" |
|||
REPUBLIC OF KOREA | KGS | Korea Gas Safety Corporation (KGS) | |
Contact
Changjoo
Seo
Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 2: Equipment protection by pressurized enclosures 'p' IEC60079: Part 6: Equipment protection by oil immersion 'o' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 15: Equipment protection by type of protection 'n' IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 26: Equipment with equipment protection level (EPL) Ga IEC60079: Part 28: Protection of equipment and transmission systems using optical radiation IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' IEC/TS60079: Explosive atmospheres - Part 46: Equipment assemblies ISO80079: Part 36: Non-electrical equipment for explosive atmospheres - Basic method and requirements ISO80079: Part 37: Non-electrical equipment for explosive atmospheres - Non electrical type of protection constructional safety "c", control of ignition source "b", liquid immersion "k" |
|||
REPUBLIC OF KOREA | KTL | Korea Testing Laboratory (KTL) | |
Contact
Dongjin
KIM
Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 2: Equipment protection by pressurized enclosures 'p' IEC60079: Part 5: Equipment protection by powder filling 'q' IEC60079: Part 6: Equipment protection by oil immersion 'o' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 13: Equipment protection by pressurized room "p" and artificially ventilated room "v" IEC60079: Part 15: Equipment protection by type of protection 'n' IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 26: Equipment with equipment protection level (EPL) Ga IEC60079: Part 27: Fieldbus intrinsically safe concept (FISCO) IEC60079: Part 28: Protection of equipment and transmission systems using optical radiation IEC/IEEE60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' IEC/TS60079: Explosive atmospheres - Part 46: Equipment assemblies ISO80079: Part 36: Non-electrical equipment for explosive atmospheres - Basic method and requirements ISO80079: Part 37: Non-electrical equipment for explosive atmospheres - Non electrical type of protection constructional safety "c", control of ignition source "b", liquid immersion "k" |
|||
REPUBLIC OF KOREA | KOSHA | Korea Occupational Safety and Health Agency (KOS) | |
Contact
Shin
Yong Woo
Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 2: Equipment protection by pressurized enclosures 'p' IEC60079: Part 5: Equipment protection by powder filling 'q' IEC60079: Part 6: Equipment protection by oil immersion 'o' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 15: Equipment protection by type of protection 'n' IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 26: Equipment with equipment protection level (EPL) Ga IEC60079: Part 28: Protection of equipment and transmission systems using optical radiation IEC60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC/IEEE60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' IEC61241: Part 0: General requirements - Electrical apparatus for use in the presence of combustible dust IEC61241: Part 1: Protection by enclosures 'tD' IEC61241: Part 1-1: Electrical apparatus protected by enclosures and surface temperature limitation - Specification for apparatus IEC61241: Part 4: Type of protection 'pD' IEC62086: Part 1: General and testing requirements - Electrical apparatus for explosive gas atmospheres – Electrical resistance trace heating |
|||
RUSSIA | NANIO CCVE | Certification Centre of explosion-proof and mine electrical equipment NANIO CCVE (CCVE) | |
Contact
Alexander
Zalogin
Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 2: Equipment protection by pressurized enclosures 'p' IEC60079: Part 5: Equipment protection by powder filling 'q' IEC60079: Part 6: Equipment protection by oil immersion 'o' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 13: Equipment protection by pressurized room "p" and artificially ventilated room "v" IEC60079: Part 15: Equipment protection by type of protection 'n' IEC60079: Part 16: Artificial ventilation for the protection of analyser (s) houses IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 25: Intrinsically safe electrical systems IEC60079: Part 26: Equipment with equipment protection level (EPL) Ga IEC60079: Part 27: Fieldbus intrinsically safe concept (FISCO) IEC60079: Part 28: Protection of equipment and transmission systems using optical radiation IEC60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC/IEEE60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' **IEC/TS60079: Edition 1.0 Explosive atmospheres - Part 32-1: Electrostatic Hazards - Guidance ** This TS may be used for testing purposes but not for issuing an IECEx Certificate of Conformity IEC60079: Part 33: Equipment protection by special protection 's' IEC60079: Part 35-1: Caplights for use in mines susceptible to firedamp - General requirements - Construction and testing in relation to the risk of explosion IEC60079: Part 35-2: Caplights for use in mines susceptible to firedamp - Performance IEC/TS60079: Part 39: Intrinsically safe systems with electronically controlled spark duration limitation IEC/TS60079: Part 40: Requirements for process sealing between flammable process fluids and electrical systems IEC/TS60079: Explosive atmospheres - Part 46: Equipment assemblies IEC61241: Part 0: General requirements - Electrical apparatus for use in the presence of combustible dust IEC61241: Part 1: Protection by enclosures 'tD' IEC61241: Part 1-1: Electrical apparatus protected by enclosures and surface temperature limitation - Specification for apparatus IEC61241: Part 4: Type of protection 'pD' IEC61241: Part 11: Protection by intrinsic safety 'iD' IEC61241: Part 18: Protection by encapsulation 'mD' IEC62013: Part 1: General requirements - Construction and testing in relation to the risk of explosion - Caplights for use in mines susceptible to firedamp IEC62013: Part 2: Performance and other safety-related matters - Caplights for use in mines susceptible to firedamp ISO80079: Part 36: Non-electrical equipment for explosive atmospheres - Basic method and requirements ISO80079: Part 37: Non-electrical equipment for explosive atmospheres - Non electrical type of protection constructional safety "c", control of ignition source "b", liquid immersion "k" DS2015/001A: IECEx Assessment and Certification of Equipment assemblies |
|||
SLOVENIA | SIQ | Slovenian Institute of Quality and Metrology | |
Contact
Matej
Debenc
+386 1 4778 100 Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 15: Equipment protection by type of protection 'n' IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 28: Protection of equipment and transmission systems using optical radiation IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' IEC60079: Part 35-1: Caplights for use in mines susceptible to firedamp - General requirements - Construction and testing in relation to the risk of explosion IEC/TS60079: Explosive atmospheres - Part 46: Equipment assemblies IEC62013: Part 1: General requirements - Construction and testing in relation to the risk of explosion - Caplights for use in mines susceptible to firedamp ISO80079: Part 36: Non-electrical equipment for explosive atmospheres - Basic method and requirements ISO80079: Part 37: Non-electrical equipment for explosive atmospheres - Non electrical type of protection constructional safety "c", control of ignition source "b", liquid immersion "k" DS2015/001A: IECEx Assessment and Certification of Equipment assemblies |
|||
SOUTH AFRICA | MASC | Mining and Surface Certification (ICS) | |
Contact
Francoius
du Toit
+27 (0) 12 653 7594 Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 5: Equipment protection by powder filling 'q' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 15: Equipment protection by type of protection 'n' IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 25: Intrinsically safe electrical systems IEC60079: Part 26: Equipment with equipment protection level (EPL) Ga IEC60079: Part 28: Protection of equipment and transmission systems using optical radiation IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' IEC60079: Part 33: Equipment protection by special protection 's' IEC60079: Part 35-1: Caplights for use in mines susceptible to firedamp - General requirements - Construction and testing in relation to the risk of explosion IEC60079: Part 35-2: Caplights for use in mines susceptible to firedamp - Performance IEC/TS60079: Explosive atmospheres - Part 46: Equipment assemblies ISO80079: Part 36: Non-electrical equipment for explosive atmospheres - Basic method and requirements ISO80079: Part 37: Non-electrical equipment for explosive atmospheres - Non electrical type of protection constructional safety "c", control of ignition source "b", liquid immersion "k" |
|||
SPAIN | LOM | LABORATORIO OFICIAL J.M. MADARIAGA | |
Contact
Natalia
Vazquez
LOM Laboratorio Oficial J.M. Madariaga +34 914421366 Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 2: Equipment protection by pressurized enclosures 'p' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 15: Equipment protection by type of protection 'n' IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 25: Intrinsically safe electrical systems IEC60079: Part 26: Equipment with equipment protection level (EPL) Ga IEC60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC/IEEE60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' IEC60079: Part 35-1: Caplights for use in mines susceptible to firedamp - General requirements - Construction and testing in relation to the risk of explosion IEC/TS60079: Explosive atmospheres - Part 46: Equipment assemblies IEC61241: Part 4: Type of protection 'pD' IEC62013: Part 1: General requirements - Construction and testing in relation to the risk of explosion - Caplights for use in mines susceptible to firedamp ISO80079: Part 36: Non-electrical equipment for explosive atmospheres - Basic method and requirements ISO80079: Part 37: Non-electrical equipment for explosive atmospheres - Non electrical type of protection constructional safety "c", control of ignition source "b", liquid immersion "k" |
|||
SWEDEN | RISE | RISE Research Institutes of Sweden AB (RISE & SP) | |
Contact
Hussni
Al-Farra
+46 10 516 53 96 Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 2: Equipment protection by pressurized enclosures 'p' IEC60079: Part 5: Equipment protection by powder filling 'q' IEC60079: Part 6: Equipment protection by oil immersion 'o' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 15: Equipment protection by type of protection 'n' IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 25: Intrinsically safe electrical systems IEC60079: Part 26: Equipment with equipment protection level (EPL) Ga IEC60079: Part 27: Fieldbus intrinsically safe concept (FISCO) IEC60079: Part 28: Protection of equipment and transmission systems using optical radiation IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' IEC61241: Part 0: General requirements - Electrical apparatus for use in the presence of combustible dust IEC61241: Part 1: Protection by enclosures 'tD' IEC61241: Part 1-1: Electrical apparatus protected by enclosures and surface temperature limitation - Specification for apparatus IEC61241: Part 4: Type of protection 'pD' IEC61241: Part 11: Protection by intrinsic safety 'iD' IEC61241: Part 18: Protection by encapsulation 'mD' IEC62784: Vacuum cleaners and dust extractors providing equipment protection level Dc for the collection of combustible dusts - Particular requirements ISO80079: Part 36: Non-electrical equipment for explosive atmospheres - Basic method and requirements ISO80079: Part 37: Non-electrical equipment for explosive atmospheres - Non electrical type of protection constructional safety "c", control of ignition source "b", liquid immersion "k" ISO16852: Flame arresters - Performance requirements, test methods and limits for use Notes
Note: IEC 60079-28 Part 28: Protection of equipment and transmission systems using optical radiation (Restricted to covering “op is” according to 5.2.4) |
|||
SWITZERLAND | SEV | Eurofins Electric & Electronic Product Testing AG | |
Contact
Holger
Schaffer
+49 33631 888-901 Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 2: Equipment protection by pressurized enclosures 'p' IEC60079: Part 5: Equipment protection by powder filling 'q' IEC60079: Part 6: Equipment protection by oil immersion 'o' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 15: Equipment protection by type of protection 'n' IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 26: Equipment with equipment protection level (EPL) Ga IEC60079: Part 28: Protection of equipment and transmission systems using optical radiation IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' IEC/TS60079: Part 40: Requirements for process sealing between flammable process fluids and electrical systems IEC/TS60079: Explosive atmospheres - Part 46: Equipment assemblies IEC/TS60079: Explosive atmospheres – Part 47: Equipment protection by 2-wire intrinsically safe Ethernet concept (2-WISE) IEC61241: Part 0: General requirements - Electrical apparatus for use in the presence of combustible dust IEC61241: Part 1: Protection by enclosures 'tD' IEC61241: Part 1-1: Electrical apparatus protected by enclosures and surface temperature limitation - Specification for apparatus IEC61241: Part 4: Type of protection 'pD' IEC61241: Part 11: Protection by intrinsic safety 'iD' IEC61241: Part 18: Protection by encapsulation 'mD' ISO80079: Part 36: Non-electrical equipment for explosive atmospheres - Basic method and requirements ISO80079: Part 37: Non-electrical equipment for explosive atmospheres - Non electrical type of protection constructional safety "c", control of ignition source "b", liquid immersion "k" DS2015/001A: IECEx Assessment and Certification of Equipment assemblies Notes
|
|||
TÜRKIYE | SZUT | SZUTEST Uygunluk Değerlandirme A.Ş. | |
Contact
Ali
Kiremitci
Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 2: Equipment protection by pressurized enclosures 'p' IEC60079: Part 6: Equipment protection by oil immersion 'o' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 15: Equipment protection by type of protection 'n' IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 26: Equipment with equipment protection level (EPL) Ga IEC60079: Part 28: Protection of equipment and transmission systems using optical radiation IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' IEC/TS60079: Explosive atmospheres - Part 46: Equipment assemblies ISO80079: Part 36: Non-electrical equipment for explosive atmospheres - Basic method and requirements ISO80079: Part 37: Non-electrical equipment for explosive atmospheres - Non electrical type of protection constructional safety "c", control of ignition source "b", liquid immersion "k" |
|||
UNITED KINGDOM | ExVeritas | ExVeritas Limited (EXV) | |
Contact
Sean
Clarke
Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 2: Equipment protection by pressurized enclosures 'p' IEC60079: Part 5: Equipment protection by powder filling 'q' IEC60079: Part 6: Equipment protection by oil immersion 'o' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 13: Equipment protection by pressurized room "p" and artificially ventilated room "v" IEC60079: Part 15: Equipment protection by type of protection 'n' IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 25: Intrinsically safe electrical systems IEC60079: Part 26: Equipment with equipment protection level (EPL) Ga IEC60079: Part 27: Fieldbus intrinsically safe concept (FISCO) IEC60079: Part 28: Protection of equipment and transmission systems using optical radiation IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' IEC60079: Part 33: Equipment protection by special protection 's' IEC/TS60079: Explosive atmospheres - Part 46: Equipment assemblies IEC/TS60079: Explosive atmospheres – Part 47: Equipment protection by 2-wire intrinsically safe Ethernet concept (2-WISE) IEC61241: Part 0: General requirements - Electrical apparatus for use in the presence of combustible dust IEC61241: Part 1: Protection by enclosures 'tD' IEC61241: Part 1-1: Electrical apparatus protected by enclosures and surface temperature limitation - Specification for apparatus IEC61241: Part 4: Type of protection 'pD' IEC61241: Part 18: Protection by encapsulation 'mD' ISO80079: Part 36: Non-electrical equipment for explosive atmospheres - Basic method and requirements ISO80079: Part 37: Non-electrical equipment for explosive atmospheres - Non electrical type of protection constructional safety "c", control of ignition source "b", liquid immersion "k" |
|||
UNITED KINGDOM | SGS | SGS UK Ltd | |
Contact
Glenn
Manifiold
Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 2: Equipment protection by pressurized enclosures 'p' IEC60079: Part 5: Equipment protection by powder filling 'q' IEC60079: Part 6: Equipment protection by oil immersion 'o' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 13: Equipment protection by pressurized room "p" and artificially ventilated room "v" IEC60079: Part 15: Equipment protection by type of protection 'n' IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 25: Intrinsically safe electrical systems IEC60079: Part 26: Equipment with equipment protection level (EPL) Ga IEC60079: Part 27: Fieldbus intrinsically safe concept (FISCO) IEC60079: Part 28: Protection of equipment and transmission systems using optical radiation IEC60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC/IEEE60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' IEC60079: Part 33: Equipment protection by special protection 's' IEC60079: Part 35-1: Caplights for use in mines susceptible to firedamp - General requirements - Construction and testing in relation to the risk of explosion IEC60079: Part 35-2: Caplights for use in mines susceptible to firedamp - Performance IEC/TS60079: Explosive atmospheres - Part 46: Equipment assemblies IEC61241: Part 0: General requirements - Electrical apparatus for use in the presence of combustible dust IEC61241: Part 1: Protection by enclosures 'tD' IEC61241: Part 1-1: Electrical apparatus protected by enclosures and surface temperature limitation - Specification for apparatus IEC61241: Part 11: Protection by intrinsic safety 'iD' IEC61241: Part 18: Protection by encapsulation 'mD' IEC62013: Part 1: General requirements - Construction and testing in relation to the risk of explosion - Caplights for use in mines susceptible to firedamp IEC62013: Part 2: Performance and other safety-related matters - Caplights for use in mines susceptible to firedamp IEC62086: Part 1: General and testing requirements - Electrical apparatus for explosive gas atmospheres – Electrical resistance trace heating ISO80079: Part 36: Non-electrical equipment for explosive atmospheres - Basic method and requirements ISO80079: Part 37: Non-electrical equipment for explosive atmospheres - Non electrical type of protection constructional safety "c", control of ignition source "b", liquid immersion "k" DS2015/001A: IECEx Assessment and Certification of Equipment assemblies Notes
|
|||
UNITED KINGDOM | ITS | Intertek Testing & Certification Limited UK (ITS) | |
Contact
Adrian
Smart
+44 1372370900 Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 2: Equipment protection by pressurized enclosures 'p' IEC60079: Part 5: Equipment protection by powder filling 'q' IEC60079: Part 6: Equipment protection by oil immersion 'o' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 13: Equipment protection by pressurized room "p" and artificially ventilated room "v" IEC60079: Part 15: Equipment protection by type of protection 'n' IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 25: Intrinsically safe electrical systems IEC60079: Part 26: Equipment with equipment protection level (EPL) Ga IEC60079: Part 27: Fieldbus intrinsically safe concept (FISCO) IEC60079: Part 28: Protection of equipment and transmission systems using optical radiation IEC60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC/IEEE60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' IEC60079: Part 33: Equipment protection by special protection 's' IEC60079: Part 35-1: Caplights for use in mines susceptible to firedamp - General requirements - Construction and testing in relation to the risk of explosion IEC/TS60079: Explosive atmospheres - Part 46: Equipment assemblies IEC61241: Part 0: General requirements - Electrical apparatus for use in the presence of combustible dust IEC61241: Part 1: Protection by enclosures 'tD' IEC61241: Part 1-1: Electrical apparatus protected by enclosures and surface temperature limitation - Specification for apparatus IEC61241: Part 4: Type of protection 'pD' IEC61241: Part 11: Protection by intrinsic safety 'iD' IEC61241: Part 18: Protection by encapsulation 'mD' IEC62013: Part 1: General requirements - Construction and testing in relation to the risk of explosion - Caplights for use in mines susceptible to firedamp IEC62013: Part 2: Performance and other safety-related matters - Caplights for use in mines susceptible to firedamp IEC62086: Part 1: General and testing requirements - Electrical apparatus for explosive gas atmospheres – Electrical resistance trace heating ISO80079: Part 36: Non-electrical equipment for explosive atmospheres - Basic method and requirements ISO80079: Part 37: Non-electrical equipment for explosive atmospheres - Non electrical type of protection constructional safety "c", control of ignition source "b", liquid immersion "k" DS2015/001A: IECEx Assessment and Certification of Equipment assemblies Notes
Note: IEC 60079-28 excluding ignition tests to 5.2.4 for Intertek Testing Services NA, Inc - Plano TX USA |
|||
UNITED KINGDOM | FM EU | FM Approvals (FME) | |
Contact
Andrew
Was
Voyager Place Dir: +44 (0) 1753 750475 or +44 (0) 1753 750000 +44 (0) 1753 868700 Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 2: Equipment protection by pressurized enclosures 'p' IEC60079: Part 5: Equipment protection by powder filling 'q' IEC60079: Part 6: Equipment protection by oil immersion 'o' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 15: Equipment protection by type of protection 'n' IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 25: Intrinsically safe electrical systems IEC60079: Part 26: Equipment with equipment protection level (EPL) Ga IEC60079: Part 27: Fieldbus intrinsically safe concept (FISCO) IEC60079: Part 28: Protection of equipment and transmission systems using optical radiation IEC60079: Part 29-1: Gas detectors - Performance requirements of detectors for flammable gases IEC60079: Part 29-4: Gas detectors - Performance requirements of open path detectors for flammable gases IEC60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC/IEEE60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' IEC/TS60079: Part 40: Requirements for process sealing between flammable process fluids and electrical systems IEC/TS60079: Explosive atmospheres – Part 47: Equipment protection by 2-wire intrinsically safe Ethernet concept (2-WISE) IEC61779: Part 1: General requirements and test methods - Electrical apparatus for the detection and measurement of flammable gases IEC61779: Part 4: Performance requirements for group II apparatus indicating a volume fraction up to 100% lower explosive limit IEC61779: Part 5: Performance requirements for group II apparatus indicating a volume fraction up to 100% gas IEC61241: Part 0: General requirements - Electrical apparatus for use in the presence of combustible dust IEC61241: Part 1: Protection by enclosures 'tD' IEC61241: Part 1-1: Electrical apparatus protected by enclosures and surface temperature limitation - Specification for apparatus IEC61241: Part 4: Type of protection 'pD' IEC61241: Part 11: Protection by intrinsic safety 'iD' IEC61241: Part 18: Protection by encapsulation 'mD' IEC62086: Part 1: General and testing requirements - Electrical apparatus for explosive gas atmospheres – Electrical resistance trace heating IEC62990: Workplace atmospheres – Part 1: Gas detectors – Performance requirements of detectors for toxic gases ISO80079: Part 36: Non-electrical equipment for explosive atmospheres - Basic method and requirements ISO80079: Part 37: Non-electrical equipment for explosive atmospheres - Non electrical type of protection constructional safety "c", control of ignition source "b", liquid immersion "k" Notes
|
|||
UNITED KINGDOM | EMT | Element Materials Technology (EMT, TRC) | |
Contact
Stephen
Winsor
Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 2: Equipment protection by pressurized enclosures 'p' IEC60079: Part 6: Equipment protection by oil immersion 'o' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 15: Equipment protection by type of protection 'n' IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 26: Equipment with equipment protection level (EPL) Ga IEC60079: Part 28: Protection of equipment and transmission systems using optical radiation IEC60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' IEC/TS60079: Explosive atmospheres - Part 46: Equipment assemblies IEC61241: Part 0: General requirements - Electrical apparatus for use in the presence of combustible dust IEC61241: Part 1: Protection by enclosures 'tD' IEC61241: Part 4: Type of protection 'pD' IEC61241: Part 11: Protection by intrinsic safety 'iD' IEC61241: Part 18: Protection by encapsulation 'mD' ISO80079: Part 36: Non-electrical equipment for explosive atmospheres - Basic method and requirements ISO80079: Part 37: Non-electrical equipment for explosive atmospheres - Non electrical type of protection constructional safety "c", control of ignition source "b", liquid immersion "k" DS2015/001A: IECEx Assessment and Certification of Equipment assemblies |
|||
UNITED KINGDOM | CML | Eurofins E&E CML Limited (CML) | |
Contact
Andy
Smith
Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 2: Equipment protection by pressurized enclosures 'p' IEC60079: Part 5: Equipment protection by powder filling 'q' IEC60079: Part 6: Equipment protection by oil immersion 'o' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 13: Equipment protection by pressurized room "p" and artificially ventilated room "v" IEC60079: Part 15: Equipment protection by type of protection 'n' IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 25: Intrinsically safe electrical systems IEC60079: Part 26: Equipment with equipment protection level (EPL) Ga IEC60079: Part 27: Fieldbus intrinsically safe concept (FISCO) IEC60079: Part 28: Protection of equipment and transmission systems using optical radiation IEC60079: Part 29-1: Gas detectors - Performance requirements of detectors for flammable gases IEC60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC/IEEE60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' IEC60079: Part 33: Equipment protection by special protection 's' IEC60079: Part 35-1: Caplights for use in mines susceptible to firedamp - General requirements - Construction and testing in relation to the risk of explosion IEC60079: Part 35-2: Caplights for use in mines susceptible to firedamp - Performance IEC/TS60079: Part 39: Intrinsically safe systems with electronically controlled spark duration limitation IEC/TS60079: Part 40: Requirements for process sealing between flammable process fluids and electrical systems IEC/TS60079: Explosive atmospheres - Part 46: Equipment assemblies IEC/TS60079: Explosive atmospheres – Part 47: Equipment protection by 2-wire intrinsically safe Ethernet concept (2-WISE) IEC61241: Part 0: General requirements - Electrical apparatus for use in the presence of combustible dust IEC61241: Part 1: Protection by enclosures 'tD' IEC61241: Part 4: Type of protection 'pD' IEC61241: Part 11: Protection by intrinsic safety 'iD' IEC61241: Part 18: Protection by encapsulation 'mD' IEC62013: Part 1: General requirements - Construction and testing in relation to the risk of explosion - Caplights for use in mines susceptible to firedamp ISO80079: Part 36: Non-electrical equipment for explosive atmospheres - Basic method and requirements ISO80079: Part 37: Non-electrical equipment for explosive atmospheres - Non electrical type of protection constructional safety "c", control of ignition source "b", liquid immersion "k" |
|||
UNITED KINGDOM | CSAE | CSA Group Testing UK Ltd (previously SIRA, now manages all certs & rpts issued with SIR ID) | |
Contact
Bryn
Spencer
Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 2: Equipment protection by pressurized enclosures 'p' IEC60079: Part 5: Equipment protection by powder filling 'q' IEC60079: Part 6: Equipment protection by oil immersion 'o' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 13: Equipment protection by pressurized room "p" and artificially ventilated room "v" IEC60079: Part 15: Equipment protection by type of protection 'n' IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 25: Intrinsically safe electrical systems IEC60079: Part 26: Equipment with equipment protection level (EPL) Ga IEC60079: Part 27: Fieldbus intrinsically safe concept (FISCO) IEC60079: Part 28: Protection of equipment and transmission systems using optical radiation IEC60079: Part 29-1: Gas detectors - Performance requirements of detectors for flammable gases IEC60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC/IEEE60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' IEC60079: Part 35-1: Caplights for use in mines susceptible to firedamp - General requirements - Construction and testing in relation to the risk of explosion IEC/TS60079: Part 40: Requirements for process sealing between flammable process fluids and electrical systems IEC/TS60079: Explosive atmospheres - Part 46: Equipment assemblies IEC61779: Part 1: General requirements and test methods - Electrical apparatus for the detection and measurement of flammable gases IEC61779: Part 2: Performance requirements for group I apparatus indicating a volume fraction up to 5% methane in air IEC61779: Part 3: Performance requirements for group I apparatus indicating a volume fraction up to 100% methane in air IEC61779: Part 4: Performance requirements for group II apparatus indicating a volume fraction up to 100% lower explosive limit IEC61779: Part 5: Performance requirements for group II apparatus indicating a volume fraction up to 100% gas IEC61241: Part 0: General requirements - Electrical apparatus for use in the presence of combustible dust IEC61241: Part 1: Protection by enclosures 'tD' IEC61241: Part 1-1: Electrical apparatus protected by enclosures and surface temperature limitation - Specification for apparatus IEC61241: Part 4: Type of protection 'pD' IEC61241: Part 11: Protection by intrinsic safety 'iD' IEC61241: Part 18: Protection by encapsulation 'mD' IEC62013: Part 1: General requirements - Construction and testing in relation to the risk of explosion - Caplights for use in mines susceptible to firedamp IEC62086: Part 1: General and testing requirements - Electrical apparatus for explosive gas atmospheres – Electrical resistance trace heating ISO80079: Part 36: Non-electrical equipment for explosive atmospheres - Basic method and requirements ISO80079: Part 37: Non-electrical equipment for explosive atmospheres - Non electrical type of protection constructional safety "c", control of ignition source "b", liquid immersion "k" |
|||
UNITED STATES OF AMERICA | UL | UL Solutions (US) | |
Contact
Katy
Holdredge
+1 847 664 2321 Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 2: Equipment protection by pressurized enclosures 'p' IEC60079: Part 5: Equipment protection by powder filling 'q' IEC60079: Part 6: Equipment protection by oil immersion 'o' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 13: Equipment protection by pressurized room "p" and artificially ventilated room "v" IEC60079: Part 15: Equipment protection by type of protection 'n' IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 25: Intrinsically safe electrical systems IEC60079: Part 26: Equipment with equipment protection level (EPL) Ga IEC60079: Part 27: Fieldbus intrinsically safe concept (FISCO) IEC60079: Part 28: Protection of equipment and transmission systems using optical radiation IEC60079: Part 29-1: Gas detectors - Performance requirements of detectors for flammable gases IEC60079: Part 29-4: Gas detectors - Performance requirements of open path detectors for flammable gases IEC60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC/IEEE60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' IEC60079: Part 33: Equipment protection by special protection 's' IEC/TS60079: Part 40: Requirements for process sealing between flammable process fluids and electrical systems IEC/TS60079: Explosive atmospheres - Part 46: Equipment assemblies IEC/TS60079: Explosive atmospheres – Part 47: Equipment protection by 2-wire intrinsically safe Ethernet concept (2-WISE) IEC61241: Part 0: General requirements - Electrical apparatus for use in the presence of combustible dust IEC61241: Part 1: Protection by enclosures 'tD' IEC61241: Part 1-1: Electrical apparatus protected by enclosures and surface temperature limitation - Specification for apparatus IEC61241: Part 4: Type of protection 'pD' IEC61241: Part 11: Protection by intrinsic safety 'iD' IEC61241: Part 18: Protection by encapsulation 'mD' IEC62086: Part 1: General and testing requirements - Electrical apparatus for explosive gas atmospheres – Electrical resistance trace heating IEC62784: Vacuum cleaners and dust extractors providing equipment protection level Dc for the collection of combustible dusts - Particular requirements ISO80079: Part 36: Non-electrical equipment for explosive atmospheres - Basic method and requirements ISO80079: Part 37: Non-electrical equipment for explosive atmospheres - Non electrical type of protection constructional safety "c", control of ignition source "b", liquid immersion "k" DS2015/001A: IECEx Assessment and Certification of Equipment assemblies |
|||
UNITED STATES OF AMERICA | SNA | SGS North America inc. | |
Contact
Vijayaraghavan
Rangarajan
Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 2: Equipment protection by pressurized enclosures 'p' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 15: Equipment protection by type of protection 'n' IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 28: Protection of equipment and transmission systems using optical radiation IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' |
|||
UNITED STATES OF AMERICA | ITS US | Intertek Testing Services NA, Inc. US (ETL) | |
Contact
Bill
Fiske
Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 2: Equipment protection by pressurized enclosures 'p' IEC60079: Part 5: Equipment protection by powder filling 'q' IEC60079: Part 6: Equipment protection by oil immersion 'o' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 13: Equipment protection by pressurized room "p" and artificially ventilated room "v" IEC60079: Part 15: Equipment protection by type of protection 'n' IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 25: Intrinsically safe electrical systems IEC60079: Part 26: Equipment with equipment protection level (EPL) Ga IEC60079: Part 28: Protection of equipment and transmission systems using optical radiation IEC60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC/IEEE60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' IEC/TS60079: Part 40: Requirements for process sealing between flammable process fluids and electrical systems IEC/TS60079: Explosive atmospheres - Part 46: Equipment assemblies IEC61241: Part 0: General requirements - Electrical apparatus for use in the presence of combustible dust IEC61241: Part 1: Protection by enclosures 'tD' IEC61241: Part 1-1: Electrical apparatus protected by enclosures and surface temperature limitation - Specification for apparatus IEC61241: Part 4: Type of protection 'pD' IECExOD 290: IECEx Certified Equipment Scheme - Harmonized procedures for IECEx certification of equipment, components and systems associated with the production, dispensing and use of gaseous hydrogen ISO19880: Gaseous hydrogen - Fuelling stations Part 1 General requirements ISO80079: Part 36: Non-electrical equipment for explosive atmospheres - Basic method and requirements ISO80079: Part 37: Non-electrical equipment for explosive atmospheres - Non electrical type of protection constructional safety "c", control of ignition source "b", liquid immersion "k" Notes
|
|||
UNITED STATES OF AMERICA | FM | FM Approvals LLC (FMG) | |
Contact
James
Marquedant
1 Technology Way Postal Address +1 (781) 255 4825 Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 2: Equipment protection by pressurized enclosures 'p' IEC60079: Part 5: Equipment protection by powder filling 'q' IEC60079: Part 6: Equipment protection by oil immersion 'o' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 15: Equipment protection by type of protection 'n' IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 25: Intrinsically safe electrical systems IEC60079: Part 26: Equipment with equipment protection level (EPL) Ga IEC60079: Part 27: Fieldbus intrinsically safe concept (FISCO) IEC60079: Part 28: Protection of equipment and transmission systems using optical radiation IEC60079: Part 29-1: Gas detectors - Performance requirements of detectors for flammable gases IEC60079: Part 29-4: Gas detectors - Performance requirements of open path detectors for flammable gases IEC60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC/IEEE60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' IEC/TS60079: Part 40: Requirements for process sealing between flammable process fluids and electrical systems IEC/TS60079: Explosive atmospheres – Part 47: Equipment protection by 2-wire intrinsically safe Ethernet concept (2-WISE) IEC61779: Part 1: General requirements and test methods - Electrical apparatus for the detection and measurement of flammable gases IEC61779: Part 4: Performance requirements for group II apparatus indicating a volume fraction up to 100% lower explosive limit IEC61779: Part 5: Performance requirements for group II apparatus indicating a volume fraction up to 100% gas IEC61241: Part 0: General requirements - Electrical apparatus for use in the presence of combustible dust IEC61241: Part 1: Protection by enclosures 'tD' IEC61241: Part 1-1: Electrical apparatus protected by enclosures and surface temperature limitation - Specification for apparatus IEC61241: Part 4: Type of protection 'pD' IEC61241: Part 11: Protection by intrinsic safety 'iD' IEC61241: Part 18: Protection by encapsulation 'mD' IEC62086: Part 1: General and testing requirements - Electrical apparatus for explosive gas atmospheres – Electrical resistance trace heating IEC62990: Workplace atmospheres – Part 1: Gas detectors – Performance requirements of detectors for toxic gases ISO80079: Part 36: Non-electrical equipment for explosive atmospheres - Basic method and requirements ISO80079: Part 37: Non-electrical equipment for explosive atmospheres - Non electrical type of protection constructional safety "c", control of ignition source "b", liquid immersion "k" |