Conditions for ExCBs
To be eligible to join the IECEx, a certification body (CB) must be first endorsed by the IECEx Member Body and pass an initial peer assessment. The member bodies then vote to approve the acceptance of the CB into the IECEx Scheme.
Then, in order to remain a member, it must be regularly reassessed.
Prerequisites for acceptance include that:
- the certification body be located in a participating country
- its certification operations are recognized within its own country
- through peer assessment, it can demonstrate its ability to comply with the IECEx rules
- through peer assessment, it can demonstrate competence and knowledge of the relevant IEC and ISO International Standards
- the certification body may not be part of, or be under the influence of, any manufacturing interests
- the CB has a Ex testing laboratory (ExTL) within its organization, or will have an agreement to work with an accepted ExTL. The ExTL must participate in the IECEx Proficiency Testing programs that are within is Scope.
Approved IECEx Certification Bodies (ExCBs) Certified Equipment Scheme
The following organisations have successfully completed the IECEx assessment process and are approved to operate within the IECEx Certified Equipment Scheme and to issue IECEx Test Reports (ExTRs), IECEx Quality Assessment Reports (QARs) and the Online Certificate of Conformity.
Note: The acronyms included in the Name field below are previous CBs names that may exist on certificates and reports, the CB noted is responsible for those reports.
Please find a historical summary list of changes of previously issued IECEx reports and certificates of past ExCBs, and the current ExCB now accountable for previously issued reports. click here.
Notes:
- for IECEx bodies approved to operate under the IECEx Certified Facility Scheme (Ex Repair) click here
- for IECEx bodies approved to operate under the IECEx Scheme for Certification of Personnel Competencies (CoPC) click here.
- for IECEx bodies approved to operate under the IECEx Conformity Mark licensing System click here
Country | Identifier | Name | |
---|---|---|---|
AUSTRALIA | ExTC | Ex Testing and Certification Pty Ltd (ExTC, TRA, ITA) | |
Contact
Ajay
Maira
30 Kennington Drive Postal Address +61 2 4964 5801 Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 2: Equipment protection by pressurized enclosures 'p' IEC60079: Part 5: Equipment protection by powder filling 'q' IEC60079: Part 6: Equipment protection by oil immersion 'o' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 13: Equipment protection by pressurized room "p" and artificially ventilated room "v" IEC60079: Part 15: Equipment protection by type of protection 'n' IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 25: Intrinsically safe electrical systems IEC60079: Part 26: Equipment with equipment protection level (EPL) Ga IEC60079: Part 27: Fieldbus intrinsically safe concept (FISCO) IEC60079: Part 28: Protection of equipment and transmission systems using optical radiation IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' IEC60079: Part 33: Equipment protection by special protection 's' IEC60079: Part 35-1: Caplights for use in mines susceptible to firedamp - General requirements - Construction and testing in relation to the risk of explosion IEC/TS60079: Explosive atmospheres - Part 46: Equipment assemblies IEC61241: Part 0: General requirements - Electrical apparatus for use in the presence of combustible dust IEC61241: Part 1: Protection by enclosures 'tD' IEC61241: Part 1-1: Electrical apparatus protected by enclosures and surface temperature limitation - Specification for apparatus IEC61241: Part 4: Type of protection 'pD' IEC62013: Part 1: General requirements - Construction and testing in relation to the risk of explosion - Caplights for use in mines susceptible to firedamp ISO80079: Part 36: Non-electrical equipment for explosive atmospheres - Basic method and requirements ISO80079: Part 37: Non-electrical equipment for explosive atmospheres - Non electrical type of protection constructional safety "c", control of ignition source "b", liquid immersion "k" DS2015/001A: IECEx Assessment and Certification of Equipment assemblies |
|||
AUSTRALIA | SIMTARS | Safety in Mines,Testing and Research Station (SIM) | |
Contact
Geoffrey
Barnier
Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 2: Equipment protection by pressurized enclosures 'p' IEC60079: Part 5: Equipment protection by powder filling 'q' IEC60079: Part 6: Equipment protection by oil immersion 'o' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 13: Equipment protection by pressurized room "p" and artificially ventilated room "v" IEC60079: Part 15: Equipment protection by type of protection 'n' IEC60079: Part 16: Artificial ventilation for the protection of analyser (s) houses IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 25: Intrinsically safe electrical systems IEC60079: Part 26: Equipment with equipment protection level (EPL) Ga IEC60079: Part 27: Fieldbus intrinsically safe concept (FISCO) IEC60079: Part 28: Protection of equipment and transmission systems using optical radiation IEC60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC/IEEE60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' IEC60079: Part 33: Equipment protection by special protection 's' IEC60079: Part 35-1: Caplights for use in mines susceptible to firedamp - General requirements - Construction and testing in relation to the risk of explosion IEC61241: Part 0: General requirements - Electrical apparatus for use in the presence of combustible dust IEC61241: Part 1: Protection by enclosures 'tD' IEC61241: Part 1-1: Electrical apparatus protected by enclosures and surface temperature limitation - Specification for apparatus IEC61241: Part 4: Type of protection 'pD' IEC61241: Part 11: Protection by intrinsic safety 'iD' IEC61241: Part 18: Protection by encapsulation 'mD' IEC62013: Part 1: General requirements - Construction and testing in relation to the risk of explosion - Caplights for use in mines susceptible to firedamp IEC62086: Part 1: General and testing requirements - Electrical apparatus for explosive gas atmospheres – Electrical resistance trace heating Notes
|
|||
AUSTRALIA | TestSafe | TestSafe Australia (TSA) (MSC) | |
Contact
Ujen
Singh
919 Londonderry Road Postal Address + 61 2 4724 4900 Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 2: Equipment protection by pressurized enclosures 'p' IEC60079: Part 5: Equipment protection by powder filling 'q' IEC60079: Part 6: Equipment protection by oil immersion 'o' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 13: Equipment protection by pressurized room "p" and artificially ventilated room "v" IEC60079: Part 15: Equipment protection by type of protection 'n' IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 19: Equipment repair, overhaul and reclamation IEC60079: Part 25: Intrinsically safe electrical systems IEC60079: Part 26: Equipment with equipment protection level (EPL) Ga IEC60079: Part 27: Fieldbus intrinsically safe concept (FISCO) IEC60079: Part 28: Protection of equipment and transmission systems using optical radiation IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' IEC60079: Part 33: Equipment protection by special protection 's' IEC60079: Part 35-1: Caplights for use in mines susceptible to firedamp - General requirements - Construction and testing in relation to the risk of explosion IEC/TS60079: Explosive atmospheres - Part 46: Equipment assemblies IEC61241: Part 0: General requirements - Electrical apparatus for use in the presence of combustible dust IEC61241: Part 1: Protection by enclosures 'tD' IEC61241: Part 1-1: Electrical apparatus protected by enclosures and surface temperature limitation - Specification for apparatus IEC62013: Part 1: General requirements - Construction and testing in relation to the risk of explosion - Caplights for use in mines susceptible to firedamp ISO80079: Part 36: Non-electrical equipment for explosive atmospheres - Basic method and requirements ISO80079: Part 37: Non-electrical equipment for explosive atmospheres - Non electrical type of protection constructional safety "c", control of ignition source "b", liquid immersion "k" DS2015/001A: IECEx Assessment and Certification of Equipment assemblies |
|||
BRAZIL | UL do Brasil | UL Solutions (BR) | |
Contact
Geoff
Slater
+61 2 4628 4690 Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 2: Equipment protection by pressurized enclosures 'p' IEC60079: Part 5: Equipment protection by powder filling 'q' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 15: Equipment protection by type of protection 'n' IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 25: Intrinsically safe electrical systems IEC60079: Part 26: Equipment with equipment protection level (EPL) Ga IEC60079: Part 27: Fieldbus intrinsically safe concept (FISCO) IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' |
|||
BRAZIL | NCC | NCC Certificações do Brasil Ltda. (NCC) | |
Contact
Wilson
Bonato
Avenida Orosimbo Maia, +55 19 2517 9646 +55 19 3232 9828 Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 2: Equipment protection by pressurized enclosures 'p' IEC60079: Part 5: Equipment protection by powder filling 'q' IEC60079: Part 6: Equipment protection by oil immersion 'o' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 15: Equipment protection by type of protection 'n' IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 25: Intrinsically safe electrical systems IEC60079: Part 26: Equipment with equipment protection level (EPL) Ga IEC60079: Part 27: Fieldbus intrinsically safe concept (FISCO) IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' IEC61241: Part 0: General requirements - Electrical apparatus for use in the presence of combustible dust IEC61241: Part 4: Type of protection 'pD' IEC61241: Part 11: Protection by intrinsic safety 'iD' IEC61241: Part 18: Protection by encapsulation 'mD' |
|||
CANADA | QPS | QPS Evaluation Services Inc. (QPS) | |
Contact
Rob
Kohuch
Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 2: Equipment protection by pressurized enclosures 'p' IEC60079: Part 5: Equipment protection by powder filling 'q' IEC60079: Part 6: Equipment protection by oil immersion 'o' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 13: Equipment protection by pressurized room "p" and artificially ventilated room "v" IEC60079: Part 15: Equipment protection by type of protection 'n' IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 25: Intrinsically safe electrical systems IEC60079: Part 26: Equipment with equipment protection level (EPL) Ga IEC60079: Part 27: Fieldbus intrinsically safe concept (FISCO) IEC60079: Part 28: Protection of equipment and transmission systems using optical radiation IEC60079: Part 29-1: Gas detectors - Performance requirements of detectors for flammable gases IEC60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' IEC60079: Part 35-1: Caplights for use in mines susceptible to firedamp - General requirements - Construction and testing in relation to the risk of explosion IEC/TS60079: Part 40: Requirements for process sealing between flammable process fluids and electrical systems IEC/TS60079: Explosive atmospheres - Part 46: Equipment assemblies IEC61241: Part 0: General requirements - Electrical apparatus for use in the presence of combustible dust IEC61241: Part 1: Protection by enclosures 'tD' IEC61241: Part 1-1: Electrical apparatus protected by enclosures and surface temperature limitation - Specification for apparatus IEC62013: Part 1: General requirements - Construction and testing in relation to the risk of explosion - Caplights for use in mines susceptible to firedamp IEC62013: Part 2: Performance and other safety-related matters - Caplights for use in mines susceptible to firedamp ISO80079: Part 36: Non-electrical equipment for explosive atmospheres - Basic method and requirements ISO80079: Part 37: Non-electrical equipment for explosive atmospheres - Non electrical type of protection constructional safety "c", control of ignition source "b", liquid immersion "k" DS2015/001A: IECEx Assessment and Certification of Equipment assemblies |
|||
CANADA | Labtest | LabTest Certification Inc. (LC) | |
Contact
Kavinder
Dhillon
205 - 8291 92 Street +1 604-247-0444 +1 604-247-0442 Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 2: Equipment protection by pressurized enclosures 'p' IEC60079: Part 6: Equipment protection by oil immersion 'o' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 13: Equipment protection by pressurized room "p" and artificially ventilated room "v" IEC60079: Part 15: Equipment protection by type of protection 'n' IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 25: Intrinsically safe electrical systems IEC60079: Part 26: Equipment with equipment protection level (EPL) Ga IEC60079: Part 28: Protection of equipment and transmission systems using optical radiation IEC/IEEE60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' IEC60079: Part 33: Equipment protection by special protection 's' IEC/TS60079: Explosive atmospheres - Part 46: Equipment assemblies ISO80079: Part 36: Non-electrical equipment for explosive atmospheres - Basic method and requirements ISO80079: Part 37: Non-electrical equipment for explosive atmospheres - Non electrical type of protection constructional safety "c", control of ignition source "b", liquid immersion "k" DS2015/001A: IECEx Assessment and Certification of Equipment assemblies |
|||
CANADA | CSA | CSA Group (CSA, KIWA, PTZ, ZLM) | |
Contact
Bryn
Spencer
Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 2: Equipment protection by pressurized enclosures 'p' IEC60079: Part 5: Equipment protection by powder filling 'q' IEC60079: Part 6: Equipment protection by oil immersion 'o' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 13: Equipment protection by pressurized room "p" and artificially ventilated room "v" IEC60079: Part 15: Equipment protection by type of protection 'n' IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 25: Intrinsically safe electrical systems IEC60079: Part 26: Equipment with equipment protection level (EPL) Ga IEC60079: Part 27: Fieldbus intrinsically safe concept (FISCO) IEC60079: Part 28: Protection of equipment and transmission systems using optical radiation IEC60079: Part 29-1: Gas detectors - Performance requirements of detectors for flammable gases IEC60079: Part 29-4: Gas detectors - Performance requirements of open path detectors for flammable gases IEC60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC/IEEE60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' IEC/TS60079: Part 40: Requirements for process sealing between flammable process fluids and electrical systems IEC/TS60079: Explosive atmospheres - Part 46: Equipment assemblies IEC/TS60079: Explosive atmospheres – Part 47: Equipment protection by 2-wire intrinsically safe Ethernet concept (2-WISE) IEC61779: Part 1: General requirements and test methods - Electrical apparatus for the detection and measurement of flammable gases IEC61779: Part 4: Performance requirements for group II apparatus indicating a volume fraction up to 100% lower explosive limit IEC61779: Part 5: Performance requirements for group II apparatus indicating a volume fraction up to 100% gas IEC61241: Part 0: General requirements - Electrical apparatus for use in the presence of combustible dust IEC61241: Part 1: Protection by enclosures 'tD' IEC61241: Part 1-1: Electrical apparatus protected by enclosures and surface temperature limitation - Specification for apparatus IEC61241: Part 4: Type of protection 'pD' IEC61241: Part 11: Protection by intrinsic safety 'iD' IEC61241: Part 18: Protection by encapsulation 'mD' ISO80079: Part 36: Non-electrical equipment for explosive atmospheres - Basic method and requirements ISO80079: Part 37: Non-electrical equipment for explosive atmospheres - Non electrical type of protection constructional safety "c", control of ignition source "b", liquid immersion "k" DS2015/001A: IECEx Assessment and Certification of Equipment assemblies |
|||
CROATIA | Fiditas | Fiditas d.o.o. (FIDI & EXA) | |
Contact
Marino
Kelava
Slavka Tomerlina 44 +385 1 5578 565 +385 1 5578 565 Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 2: Equipment protection by pressurized enclosures 'p' IEC60079: Part 5: Equipment protection by powder filling 'q' IEC60079: Part 6: Equipment protection by oil immersion 'o' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 13: Equipment protection by pressurized room "p" and artificially ventilated room "v" IEC60079: Part 15: Equipment protection by type of protection 'n' IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 25: Intrinsically safe electrical systems IEC60079: Part 26: Equipment with equipment protection level (EPL) Ga IEC60079: Part 27: Fieldbus intrinsically safe concept (FISCO) IEC60079: Part 28: Protection of equipment and transmission systems using optical radiation IEC60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC/IEEE60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' **IEC60079: Edition 2.0 Explosive atmospheres - Part 32-2: Electrostatics hazards – Tests ** This Standard may be used for testing purposes but not for issuing an IECEx Certificate of Conformity IEC/TS60079: Explosive atmospheres - Part 46: Equipment assemblies IEC/TS60079: Explosive atmospheres – Part 47: Equipment protection by 2-wire intrinsically safe Ethernet concept (2-WISE) IEC61241: Part 0: General requirements - Electrical apparatus for use in the presence of combustible dust IEC61241: Part 1: Protection by enclosures 'tD' IEC61241: Part 4: Type of protection 'pD' IEC61241: Part 11: Protection by intrinsic safety 'iD' IEC61241: Part 18: Protection by encapsulation 'mD' IEC62784: Vacuum cleaners and dust extractors providing equipment protection level Dc for the collection of combustible dusts - Particular requirements ISO80079: Part 36: Non-electrical equipment for explosive atmospheres - Basic method and requirements ISO80079: Part 37: Non-electrical equipment for explosive atmospheres - Non electrical type of protection constructional safety "c", control of ignition source "b", liquid immersion "k" DS2015/001A: IECEx Assessment and Certification of Equipment assemblies |
|||
CZECH REPUBLIC | FTZU | Fyzikálně technický zkušební ústav,s.p. (Physical Technical Testing Institute) (FTZU) | |
Contact
Lukas
Martinak
+420 595 223 111 Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 2: Equipment protection by pressurized enclosures 'p' IEC60079: Part 5: Equipment protection by powder filling 'q' IEC60079: Part 6: Equipment protection by oil immersion 'o' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 13: Equipment protection by pressurized room "p" and artificially ventilated room "v" IEC60079: Part 15: Equipment protection by type of protection 'n' IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 25: Intrinsically safe electrical systems IEC60079: Part 26: Equipment with equipment protection level (EPL) Ga IEC60079: Part 27: Fieldbus intrinsically safe concept (FISCO) IEC60079: Part 28: Protection of equipment and transmission systems using optical radiation IEC60079: Part 29-1: Gas detectors - Performance requirements of detectors for flammable gases IEC60079: Part 29-4: Gas detectors - Performance requirements of open path detectors for flammable gases IEC60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC/IEEE60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' IEC60079: Part 33: Equipment protection by special protection 's' IEC60079: Part 35-1: Caplights for use in mines susceptible to firedamp - General requirements - Construction and testing in relation to the risk of explosion IEC60079: Part 35-2: Caplights for use in mines susceptible to firedamp - Performance IEC/TS60079: Part 40: Requirements for process sealing between flammable process fluids and electrical systems **IEC/TS60079: Explosive atmospheres- Electrical safety devices for the control of potential ignition sources for Ex-Equipment. ** This TS may be used for testing purposes but not for issuing an IECEx Certificate of Conformity IEC/TS60079: Explosive atmospheres - Part 46: Equipment assemblies IEC/TS60079: Explosive atmospheres – Part 47: Equipment protection by 2-wire intrinsically safe Ethernet concept (2-WISE) IEC61779: Part 1: General requirements and test methods - Electrical apparatus for the detection and measurement of flammable gases IEC61779: Part 2: Performance requirements for group I apparatus indicating a volume fraction up to 5% methane in air IEC61779: Part 3: Performance requirements for group I apparatus indicating a volume fraction up to 100% methane in air IEC61779: Part 4: Performance requirements for group II apparatus indicating a volume fraction up to 100% lower explosive limit IEC61779: Part 5: Performance requirements for group II apparatus indicating a volume fraction up to 100% gas IEC61241: Part 0: General requirements - Electrical apparatus for use in the presence of combustible dust IEC61241: Part 1: Protection by enclosures 'tD' IEC61241: Part 1-1: Electrical apparatus protected by enclosures and surface temperature limitation - Specification for apparatus IEC61241: Part 4: Type of protection 'pD' IEC61241: Part 11: Protection by intrinsic safety 'iD' IEC61241: Part 18: Protection by encapsulation 'mD' IEC62013: Part 1: General requirements - Construction and testing in relation to the risk of explosion - Caplights for use in mines susceptible to firedamp IEC62013: Part 2: Performance and other safety-related matters - Caplights for use in mines susceptible to firedamp IEC62086: Part 1: General and testing requirements - Electrical apparatus for explosive gas atmospheres – Electrical resistance trace heating IEC62784: Vacuum cleaners and dust extractors providing equipment protection level Dc for the collection of combustible dusts - Particular requirements IEC62990: Workplace atmospheres – Part 1: Gas detectors – Performance requirements of detectors for toxic gases ISO80079: Part 36: Non-electrical equipment for explosive atmospheres - Basic method and requirements ISO80079: Part 37: Non-electrical equipment for explosive atmospheres - Non electrical type of protection constructional safety "c", control of ignition source "b", liquid immersion "k" ISO16852: Flame arresters - Performance requirements, test methods and limits for use DS2015/001A: IECEx Assessment and Certification of Equipment assemblies TR60079: Part 16: Artificial ventilation for the protection of analyser(s) houses |
|||
DENMARK | UL/Demko | UL Solutions (Demko) | |
Contact
Jasmin
Omerovic
Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 2: Equipment protection by pressurized enclosures 'p' IEC60079: Part 5: Equipment protection by powder filling 'q' IEC60079: Part 6: Equipment protection by oil immersion 'o' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 13: Equipment protection by pressurized room "p" and artificially ventilated room "v" IEC60079: Part 15: Equipment protection by type of protection 'n' IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 25: Intrinsically safe electrical systems IEC60079: Part 26: Equipment with equipment protection level (EPL) Ga IEC60079: Part 27: Fieldbus intrinsically safe concept (FISCO) IEC60079: Part 28: Protection of equipment and transmission systems using optical radiation IEC60079: Part 29-1: Gas detectors - Performance requirements of detectors for flammable gases IEC60079: Part 29-4: Gas detectors - Performance requirements of open path detectors for flammable gases IEC60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC/IEEE60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' IEC60079: Part 33: Equipment protection by special protection 's' IEC60079: Part 35-1: Caplights for use in mines susceptible to firedamp - General requirements - Construction and testing in relation to the risk of explosion IEC/TS60079: Part 40: Requirements for process sealing between flammable process fluids and electrical systems **IEC/TS60079: Explosive atmospheres- Electrical safety devices for the control of potential ignition sources for Ex-Equipment. ** This TS may be used for testing purposes but not for issuing an IECEx Certificate of Conformity IEC/TS60079: Explosive atmospheres - Part 46: Equipment assemblies IEC/TS60079: Explosive atmospheres – Part 47: Equipment protection by 2-wire intrinsically safe Ethernet concept (2-WISE) IEC61241: Part 0: General requirements - Electrical apparatus for use in the presence of combustible dust IEC61241: Part 1: Protection by enclosures 'tD' IEC61241: Part 1-1: Electrical apparatus protected by enclosures and surface temperature limitation - Specification for apparatus IEC61241: Part 4: Type of protection 'pD' IEC61241: Part 11: Protection by intrinsic safety 'iD' IEC61241: Part 18: Protection by encapsulation 'mD' IEC62086: Part 1: General and testing requirements - Electrical apparatus for explosive gas atmospheres – Electrical resistance trace heating IEC62784: Vacuum cleaners and dust extractors providing equipment protection level Dc for the collection of combustible dusts - Particular requirements ISO80079: Part 36: Non-electrical equipment for explosive atmospheres - Basic method and requirements ISO80079: Part 37: Non-electrical equipment for explosive atmospheres - Non electrical type of protection constructional safety "c", control of ignition source "b", liquid immersion "k" |
|||
FINLAND | EESF | Eurofins Electric & Electronics Finland Oy (EESF) | |
Contact
Jenni
Hirvelä
Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 2: Equipment protection by pressurized enclosures 'p' IEC60079: Part 5: Equipment protection by powder filling 'q' IEC60079: Part 6: Equipment protection by oil immersion 'o' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 15: Equipment protection by type of protection 'n' IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 25: Intrinsically safe electrical systems IEC60079: Part 26: Equipment with equipment protection level (EPL) Ga IEC60079: Part 27: Fieldbus intrinsically safe concept (FISCO) IEC60079: Part 28: Protection of equipment and transmission systems using optical radiation IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' IEC/TS60079: Explosive atmospheres - Part 46: Equipment assemblies IEC61241: Part 0: General requirements - Electrical apparatus for use in the presence of combustible dust IEC61241: Part 1: Protection by enclosures 'tD' IEC61241: Part 1-1: Electrical apparatus protected by enclosures and surface temperature limitation - Specification for apparatus IEC61241: Part 4: Type of protection 'pD' IEC61241: Part 11: Protection by intrinsic safety 'iD' IEC61241: Part 18: Protection by encapsulation 'mD' ISO80079: Part 36: Non-electrical equipment for explosive atmospheres - Basic method and requirements ISO80079: Part 37: Non-electrical equipment for explosive atmospheres - Non electrical type of protection constructional safety "c", control of ignition source "b", liquid immersion "k" DS2015/001A: IECEx Assessment and Certification of Equipment assemblies Notes
|
|||
FRANCE | LCIE | Laboratoire Central des Industries Electriques – Bureau Veritas (LCIE) | |
Contact
Marie-Elisabeth
d'Ornano
Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 2: Equipment protection by pressurized enclosures 'p' IEC60079: Part 5: Equipment protection by powder filling 'q' IEC60079: Part 6: Equipment protection by oil immersion 'o' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 13: Equipment protection by pressurized room "p" and artificially ventilated room "v" IEC60079: Part 15: Equipment protection by type of protection 'n' IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 25: Intrinsically safe electrical systems IEC60079: Part 26: Equipment with equipment protection level (EPL) Ga IEC60079: Part 27: Fieldbus intrinsically safe concept (FISCO) IEC60079: Part 28: Protection of equipment and transmission systems using optical radiation IEC60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' IEC/TS60079: Explosive atmospheres - Part 46: Equipment assemblies IEC61241: Part 0: General requirements - Electrical apparatus for use in the presence of combustible dust IEC61241: Part 1: Protection by enclosures 'tD' IEC61241: Part 1-1: Electrical apparatus protected by enclosures and surface temperature limitation - Specification for apparatus IEC61241: Part 4: Type of protection 'pD' IEC61241: Part 11: Protection by intrinsic safety 'iD' IEC61241: Part 18: Protection by encapsulation 'mD' IEC62086: Part 1: General and testing requirements - Electrical apparatus for explosive gas atmospheres – Electrical resistance trace heating ISO80079: Part 36: Non-electrical equipment for explosive atmospheres - Basic method and requirements ISO80079: Part 37: Non-electrical equipment for explosive atmospheres - Non electrical type of protection constructional safety "c", control of ignition source "b", liquid immersion "k" DS2015/001A: IECEx Assessment and Certification of Equipment assemblies |
|||
FRANCE | INERIS | INERIS - Institut National de l'Environnement Industriel et des Risques (INE) | |
Contact
Thierry
Houeix
BP n°2 / Parc Technologique ALATA +33 (0)3 44 55 64 88 +33 (0)3 44 55 67 04 Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 2: Equipment protection by pressurized enclosures 'p' IEC60079: Part 5: Equipment protection by powder filling 'q' IEC60079: Part 6: Equipment protection by oil immersion 'o' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 13: Equipment protection by pressurized room "p" and artificially ventilated room "v" IEC60079: Part 15: Equipment protection by type of protection 'n' IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 25: Intrinsically safe electrical systems IEC60079: Part 26: Equipment with equipment protection level (EPL) Ga IEC60079: Part 28: Protection of equipment and transmission systems using optical radiation IEC60079: Part 29-1: Gas detectors - Performance requirements of detectors for flammable gases IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' IEC60079: Part 33: Equipment protection by special protection 's' **IEC/TS60079: Explosive atmospheres- Electrical safety devices for the control of potential ignition sources for Ex-Equipment. ** This TS may be used for testing purposes but not for issuing an IECEx Certificate of Conformity IEC/TS60079: Explosive atmospheres - Part 46: Equipment assemblies IEC61241: Part 0: General requirements - Electrical apparatus for use in the presence of combustible dust IEC61241: Part 1: Protection by enclosures 'tD' IEC61241: Part 1-1: Electrical apparatus protected by enclosures and surface temperature limitation - Specification for apparatus IEC61241: Part 4: Type of protection 'pD' IEC61241: Part 11: Protection by intrinsic safety 'iD' IEC61241: Part 18: Protection by encapsulation 'mD' IECExOD 290: IECEx Certified Equipment Scheme - Harmonized procedures for IECEx certification of equipment, components and systems associated with the production, dispensing and use of gaseous hydrogen ISO80079: Part 36: Non-electrical equipment for explosive atmospheres - Basic method and requirements ISO80079: Part 37: Non-electrical equipment for explosive atmospheres - Non electrical type of protection constructional safety "c", control of ignition source "b", liquid immersion "k" DS2015/001A: IECEx Assessment and Certification of Equipment assemblies |
|||
GERMANY | BV | Bureau Veritas Consumer Products Services Germany GmbH (EPS) | |
Contact
Ulrich
Feike
Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 2: Equipment protection by pressurized enclosures 'p' IEC60079: Part 5: Equipment protection by powder filling 'q' IEC60079: Part 6: Equipment protection by oil immersion 'o' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 13: Equipment protection by pressurized room "p" and artificially ventilated room "v" IEC60079: Part 15: Equipment protection by type of protection 'n' IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 25: Intrinsically safe electrical systems IEC60079: Part 26: Equipment with equipment protection level (EPL) Ga IEC60079: Part 27: Fieldbus intrinsically safe concept (FISCO) IEC60079: Part 28: Protection of equipment and transmission systems using optical radiation IEC60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC/IEEE60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' IEC60079: Part 33: Equipment protection by special protection 's' IEC/TS60079: Part 40: Requirements for process sealing between flammable process fluids and electrical systems **IEC/TS60079: Explosive atmospheres- Electrical safety devices for the control of potential ignition sources for Ex-Equipment. ** This TS may be used for testing purposes but not for issuing an IECEx Certificate of Conformity IEC/TS60079: Explosive atmospheres - Part 46: Equipment assemblies IEC/TS60079: Explosive atmospheres – Part 47: Equipment protection by 2-wire intrinsically safe Ethernet concept (2-WISE) IEC61241: Part 0: General requirements - Electrical apparatus for use in the presence of combustible dust IEC61241: Part 1: Protection by enclosures 'tD' IEC61241: Part 1-1: Electrical apparatus protected by enclosures and surface temperature limitation - Specification for apparatus IEC61241: Part 4: Type of protection 'pD' IEC61241: Part 11: Protection by intrinsic safety 'iD' IEC61241: Part 18: Protection by encapsulation 'mD' IEC62086: Part 1: General and testing requirements - Electrical apparatus for explosive gas atmospheres – Electrical resistance trace heating ISO80079: Part 36: Non-electrical equipment for explosive atmospheres - Basic method and requirements ISO80079: Part 37: Non-electrical equipment for explosive atmospheres - Non electrical type of protection constructional safety "c", control of ignition source "b", liquid immersion "k" DS2015/001A: IECEx Assessment and Certification of Equipment assemblies Notes
|
|||
GERMANY | DEKRA EXAM | DEKRA Testing and Certification GmbH (BVS) | |
Contact
Ing Franz
Eickhoff
Carl-Beyling-Haus Postal Address +49.234.3696-334 +49.234.3696-301 Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 2: Equipment protection by pressurized enclosures 'p' IEC60079: Part 5: Equipment protection by powder filling 'q' IEC60079: Part 6: Equipment protection by oil immersion 'o' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 13: Equipment protection by pressurized room "p" and artificially ventilated room "v" IEC60079: Part 15: Equipment protection by type of protection 'n' IEC60079: Part 16: Artificial ventilation for the protection of analyser (s) houses IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 25: Intrinsically safe electrical systems IEC60079: Part 26: Equipment with equipment protection level (EPL) Ga IEC60079: Part 27: Fieldbus intrinsically safe concept (FISCO) IEC60079: Part 28: Protection of equipment and transmission systems using optical radiation IEC60079: Part 29-1: Gas detectors - Performance requirements of detectors for flammable gases IEC60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC/IEEE60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' IEC60079: Part 33: Equipment protection by special protection 's' IEC60079: Part 35-1: Caplights for use in mines susceptible to firedamp - General requirements - Construction and testing in relation to the risk of explosion IEC/TS60079: Part 39: Intrinsically safe systems with electronically controlled spark duration limitation IEC/TS60079: Part 40: Requirements for process sealing between flammable process fluids and electrical systems **IEC/TS60079: Explosive atmospheres- Electrical safety devices for the control of potential ignition sources for Ex-Equipment. ** This TS may be used for testing purposes but not for issuing an IECEx Certificate of Conformity IEC/TS60079: Explosive atmospheres - Part 46: Equipment assemblies IEC/TS60079: Explosive atmospheres – Part 47: Equipment protection by 2-wire intrinsically safe Ethernet concept (2-WISE) IEC61779: Part 1: General requirements and test methods - Electrical apparatus for the detection and measurement of flammable gases IEC61779: Part 2: Performance requirements for group I apparatus indicating a volume fraction up to 5% methane in air IEC61779: Part 3: Performance requirements for group I apparatus indicating a volume fraction up to 100% methane in air IEC61779: Part 4: Performance requirements for group II apparatus indicating a volume fraction up to 100% lower explosive limit IEC61779: Part 5: Performance requirements for group II apparatus indicating a volume fraction up to 100% gas IEC61241: Part 0: General requirements - Electrical apparatus for use in the presence of combustible dust IEC61241: Part 1: Protection by enclosures 'tD' IEC61241: Part 1-1: Electrical apparatus protected by enclosures and surface temperature limitation - Specification for apparatus IEC61241: Part 4: Type of protection 'pD' IEC61241: Part 11: Protection by intrinsic safety 'iD' IEC61241: Part 18: Protection by encapsulation 'mD' IEC62013: Part 1: General requirements - Construction and testing in relation to the risk of explosion - Caplights for use in mines susceptible to firedamp IEC62086: Part 1: General and testing requirements - Electrical apparatus for explosive gas atmospheres – Electrical resistance trace heating IEC62990: Workplace atmospheres – Part 1: Gas detectors – Performance requirements of detectors for toxic gases ISO80079: Part 36: Non-electrical equipment for explosive atmospheres - Basic method and requirements ISO80079: Part 37: Non-electrical equipment for explosive atmospheres - Non electrical type of protection constructional safety "c", control of ignition source "b", liquid immersion "k" DS2015/001A: IECEx Assessment and Certification of Equipment assemblies |
|||
GERMANY | TÜV Rheinland | TÜV Rheinland Industrie Service GmbH (TUR) | |
Contact
Klauspeter
Graffi
Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 2: Equipment protection by pressurized enclosures 'p' IEC60079: Part 5: Equipment protection by powder filling 'q' IEC60079: Part 6: Equipment protection by oil immersion 'o' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 13: Equipment protection by pressurized room "p" and artificially ventilated room "v" IEC60079: Part 15: Equipment protection by type of protection 'n' IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 25: Intrinsically safe electrical systems IEC60079: Part 26: Equipment with equipment protection level (EPL) Ga IEC60079: Part 27: Fieldbus intrinsically safe concept (FISCO) IEC60079: Part 28: Protection of equipment and transmission systems using optical radiation IEC60079: Part 29-1: Gas detectors - Performance requirements of detectors for flammable gases IEC60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC/IEEE60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' IEC60079: Part 33: Equipment protection by special protection 's' IEC60079: Part 35-2: Caplights for use in mines susceptible to firedamp - Performance IEC/TS60079: Explosive atmospheres - Part 46: Equipment assemblies IEC/TS60079: Explosive atmospheres – Part 47: Equipment protection by 2-wire intrinsically safe Ethernet concept (2-WISE) IEC61241: Part 0: General requirements - Electrical apparatus for use in the presence of combustible dust IEC61241: Part 1: Protection by enclosures 'tD' IEC61241: Part 4: Type of protection 'pD' IEC61241: Part 11: Protection by intrinsic safety 'iD' IEC61241: Part 18: Protection by encapsulation 'mD' IEC62990: Workplace atmospheres – Part 1: Gas detectors – Performance requirements of detectors for toxic gases ISO80079: Part 36: Non-electrical equipment for explosive atmospheres - Basic method and requirements ISO80079: Part 37: Non-electrical equipment for explosive atmospheres - Non electrical type of protection constructional safety "c", control of ignition source "b", liquid immersion "k" DS2015/001A: IECEx Assessment and Certification of Equipment assemblies |
|||
GERMANY | TUV NORD | TÜV NORD CERT GmbH (TUN) | |
Contact
Christian
Roder
Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 2: Equipment protection by pressurized enclosures 'p' IEC60079: Part 5: Equipment protection by powder filling 'q' IEC60079: Part 6: Equipment protection by oil immersion 'o' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 15: Equipment protection by type of protection 'n' IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 25: Intrinsically safe electrical systems IEC60079: Part 26: Equipment with equipment protection level (EPL) Ga IEC60079: Part 27: Fieldbus intrinsically safe concept (FISCO) IEC60079: Part 28: Protection of equipment and transmission systems using optical radiation IEC/IEEE60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' IEC/TS60079: Explosive atmospheres - Part 46: Equipment assemblies IEC61241: Part 0: General requirements - Electrical apparatus for use in the presence of combustible dust IEC61241: Part 1: Protection by enclosures 'tD' IEC61241: Part 4: Type of protection 'pD' IEC61241: Part 11: Protection by intrinsic safety 'iD' IEC61241: Part 18: Protection by encapsulation 'mD' ISO80079: Part 36: Non-electrical equipment for explosive atmospheres - Basic method and requirements ISO80079: Part 37: Non-electrical equipment for explosive atmospheres - Non electrical type of protection constructional safety "c", control of ignition source "b", liquid immersion "k" DS2015/001A: IECEx Assessment and Certification of Equipment assemblies |
|||
GERMANY | IBExU | IBExU Institut für Sicherheitstechnik GmbH (IBE) | |
Contact
Kristin
Krumbiegel
Fuchsmühlenweg 7 +49 (0) 37 31 / 38 05 0 + 49 (0) 37 31 / 38 05 10 Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 2: Equipment protection by pressurized enclosures 'p' IEC60079: Part 5: Equipment protection by powder filling 'q' IEC60079: Part 6: Equipment protection by oil immersion 'o' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 15: Equipment protection by type of protection 'n' IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 25: Intrinsically safe electrical systems IEC60079: Part 26: Equipment with equipment protection level (EPL) Ga IEC60079: Part 27: Fieldbus intrinsically safe concept (FISCO) IEC60079: Part 28: Protection of equipment and transmission systems using optical radiation IEC60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC/IEEE60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' IEC60079: Part 35-1: Caplights for use in mines susceptible to firedamp - General requirements - Construction and testing in relation to the risk of explosion IEC61241: Part 0: General requirements - Electrical apparatus for use in the presence of combustible dust IEC61241: Part 1: Protection by enclosures 'tD' IEC61241: Part 1-1: Electrical apparatus protected by enclosures and surface temperature limitation - Specification for apparatus IEC61241: Part 4: Type of protection 'pD' IEC61241: Part 11: Protection by intrinsic safety 'iD' IEC61241: Part 18: Protection by encapsulation 'mD' IEC62013: Part 1: General requirements - Construction and testing in relation to the risk of explosion - Caplights for use in mines susceptible to firedamp IEC62086: Part 1: General and testing requirements - Electrical apparatus for explosive gas atmospheres – Electrical resistance trace heating IEC62784: Vacuum cleaners and dust extractors providing equipment protection level Dc for the collection of combustible dusts - Particular requirements ISO/IEC80079: Explosive atmospheres - Part 49: Flame arresters - Performance requirements, test methods and limits of use ISO80079: Part 36: Non-electrical equipment for explosive atmospheres - Basic method and requirements ISO80079: Part 37: Non-electrical equipment for explosive atmospheres - Non electrical type of protection constructional safety "c", control of ignition source "b", liquid immersion "k" ISO16852: Flame arresters - Performance requirements, test methods and limits for use |
|||
GERMANY | PTB | Physikalisch-Technische Bundesanstalt (PTB) | |
Contact
Martin
Thedens
Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 2: Equipment protection by pressurized enclosures 'p' IEC60079: Part 5: Equipment protection by powder filling 'q' IEC60079: Part 6: Equipment protection by oil immersion 'o' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 15: Equipment protection by type of protection 'n' IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 25: Intrinsically safe electrical systems IEC60079: Part 26: Equipment with equipment protection level (EPL) Ga IEC60079: Part 27: Fieldbus intrinsically safe concept (FISCO) IEC60079: Part 28: Protection of equipment and transmission systems using optical radiation IEC60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC/IEEE60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' IEC60079: Part 33: Equipment protection by special protection 's' **IEC/TS60079: Explosive atmospheres- Electrical safety devices for the control of potential ignition sources for Ex-Equipment. ** This TS may be used for testing purposes but not for issuing an IECEx Certificate of Conformity IEC/TS60079: Explosive atmospheres - Part 46: Equipment assemblies IEC61241: Part 0: General requirements - Electrical apparatus for use in the presence of combustible dust IEC61241: Part 1: Protection by enclosures 'tD' IEC61241: Part 1-1: Electrical apparatus protected by enclosures and surface temperature limitation - Specification for apparatus IEC61241: Part 4: Type of protection 'pD' IEC61241: Part 11: Protection by intrinsic safety 'iD' IEC61241: Part 18: Protection by encapsulation 'mD' IEC62086: Part 1: General and testing requirements - Electrical apparatus for explosive gas atmospheres – Electrical resistance trace heating ISO80079: Part 36: Non-electrical equipment for explosive atmospheres - Basic method and requirements ISO80079: Part 37: Non-electrical equipment for explosive atmospheres - Non electrical type of protection constructional safety "c", control of ignition source "b", liquid immersion "k" ISO16852: Flame arresters - Performance requirements, test methods and limits for use |
|||
GERMANY | TUV SUD PS | TÜV SÜD Product Service GmbH (TPS) | |
Contact
Klaus
Lorenz
Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 2: Equipment protection by pressurized enclosures 'p' IEC60079: Part 5: Equipment protection by powder filling 'q' IEC60079: Part 6: Equipment protection by oil immersion 'o' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 13: Equipment protection by pressurized room "p" and artificially ventilated room "v" IEC60079: Part 15: Equipment protection by type of protection 'n' IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 25: Intrinsically safe electrical systems IEC60079: Part 26: Equipment with equipment protection level (EPL) Ga IEC60079: Part 28: Protection of equipment and transmission systems using optical radiation IEC/IEEE60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' IEC60079: Part 35-1: Caplights for use in mines susceptible to firedamp - General requirements - Construction and testing in relation to the risk of explosion IEC/TS60079: Explosive atmospheres - Part 46: Equipment assemblies IEC/TS60079: Explosive atmospheres – Part 47: Equipment protection by 2-wire intrinsically safe Ethernet concept (2-WISE) IEC61241: Part 0: General requirements - Electrical apparatus for use in the presence of combustible dust IEC61241: Part 1: Protection by enclosures 'tD' IEC61241: Part 1-1: Electrical apparatus protected by enclosures and surface temperature limitation - Specification for apparatus IEC61241: Part 4: Type of protection 'pD' IEC61241: Part 11: Protection by intrinsic safety 'iD' IEC61241: Part 18: Protection by encapsulation 'mD' ISO80079: Part 36: Non-electrical equipment for explosive atmospheres - Basic method and requirements ISO80079: Part 37: Non-electrical equipment for explosive atmospheres - Non electrical type of protection constructional safety "c", control of ignition source "b", liquid immersion "k" DS2015/001A: IECEx Assessment and Certification of Equipment assemblies TR60079: Part 16: Artificial ventilation for the protection of analyser(s) houses |
|||
GREECE | KR Hellas Ltd | KR Hellas Ltd, (KRH) | |
Contact
Nikos
Katiforis
Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 2: Equipment protection by pressurized enclosures 'p' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 15: Equipment protection by type of protection 'n' IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 26: Equipment with equipment protection level (EPL) Ga IEC60079: Part 28: Protection of equipment and transmission systems using optical radiation IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' |
|||
HUNGARY | BKI | ExVA Ltd (BKI) | |
Contact
Nagy
Botond
Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 2: Equipment protection by pressurized enclosures 'p' IEC60079: Part 5: Equipment protection by powder filling 'q' IEC60079: Part 6: Equipment protection by oil immersion 'o' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 15: Equipment protection by type of protection 'n' IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 26: Equipment with equipment protection level (EPL) Ga IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' IEC61779: Part 1: General requirements and test methods - Electrical apparatus for the detection and measurement of flammable gases IEC61779: Part 2: Performance requirements for group I apparatus indicating a volume fraction up to 5% methane in air IEC61779: Part 3: Performance requirements for group I apparatus indicating a volume fraction up to 100% methane in air IEC61779: Part 4: Performance requirements for group II apparatus indicating a volume fraction up to 100% lower explosive limit IEC61779: Part 5: Performance requirements for group II apparatus indicating a volume fraction up to 100% gas IEC61241: Part 0: General requirements - Electrical apparatus for use in the presence of combustible dust IEC61241: Part 1: Protection by enclosures 'tD' IEC61241: Part 1-1: Electrical apparatus protected by enclosures and surface temperature limitation - Specification for apparatus IEC61241: Part 4: Type of protection 'pD' IEC61241: Part 11: Protection by intrinsic safety 'iD' IEC61241: Part 18: Protection by encapsulation 'mD' DS2015/001A: IECEx Assessment and Certification of Equipment assemblies |
|||
INDIA | KLCS | KL Certification Services (A division of Karandikar Laboratories Pvt. Ltd.) (KLCS) | |
Contact
Ravi
Paranjpe
Gat No. 142, Boisar Chillar Rd., +91 2525 284931 Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 2: Equipment protection by pressurized enclosures 'p' IEC60079: Part 5: Equipment protection by powder filling 'q' IEC60079: Part 6: Equipment protection by oil immersion 'o' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 13: Equipment protection by pressurized room "p" and artificially ventilated room "v" IEC60079: Part 15: Equipment protection by type of protection 'n' IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 25: Intrinsically safe electrical systems IEC60079: Part 26: Equipment with equipment protection level (EPL) Ga IEC60079: Part 28: Protection of equipment and transmission systems using optical radiation IEC60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC/IEEE60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' IEC60079: Part 33: Equipment protection by special protection 's' IEC/TS60079: Explosive atmospheres - Part 46: Equipment assemblies ISO80079: Part 36: Non-electrical equipment for explosive atmospheres - Basic method and requirements ISO80079: Part 37: Non-electrical equipment for explosive atmospheres - Non electrical type of protection constructional safety "c", control of ignition source "b", liquid immersion "k" ISO16852: Flame arresters - Performance requirements, test methods and limits for use Notes
Note: IEC 60079-28 is limited to clause 5.2.2.2 and 5.2.2.3. of 5.2 (“op is”).
|
|||
ISLAMIC REPUBLIC OF IRAN | EPIL | Energy and Power Industries Laboratories Co. (EPIL) | |
Contact
Seyed
Mohsen Mirsadri
Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 28: Protection of equipment and transmission systems using optical radiation IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' |
|||
ISRAEL | ITL | I.T.L (Product Testing) LTD | |
Contact
Ilan
Cohen
Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 2: Equipment protection by pressurized enclosures 'p' IEC60079: Part 5: Equipment protection by powder filling 'q' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 15: Equipment protection by type of protection 'n' IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 26: Equipment with equipment protection level (EPL) Ga ISO80079: Part 36: Non-electrical equipment for explosive atmospheres - Basic method and requirements ISO80079: Part 37: Non-electrical equipment for explosive atmospheres - Non electrical type of protection constructional safety "c", control of ignition source "b", liquid immersion "k" Notes
Note: For IEC 60079-1 IEC 60079-2 IEC 60079-5 and IEC 60079-7 ITL use OBAC as the associated ExTL. |
|||
ITALY | EUROFINS | Eurofins Product Testing Italy Srl.(EUT) | |
Contact
Dionisio
Bucchieri
Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 2: Equipment protection by pressurized enclosures 'p' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 15: Equipment protection by type of protection 'n' IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 25: Intrinsically safe electrical systems IEC60079: Part 26: Equipment with equipment protection level (EPL) Ga IEC60079: Part 28: Protection of equipment and transmission systems using optical radiation IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' IEC/TS60079: Explosive atmospheres - Part 46: Equipment assemblies ISO/IEC80079: Explosive atmospheres - Part 49: Flame arresters - Performance requirements, test methods and limits of use ISO80079: Part 36: Non-electrical equipment for explosive atmospheres - Basic method and requirements ISO80079: Part 37: Non-electrical equipment for explosive atmospheres - Non electrical type of protection constructional safety "c", control of ignition source "b", liquid immersion "k" ISO16852: Flame arresters - Performance requirements, test methods and limits for use |
|||
ITALY | CESI | CESI – Centro Elettrotecnico Sperimentale Italiano S.p.A. | |
Contact
Alessandro
Fedato
+39 0221251 Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 2: Equipment protection by pressurized enclosures 'p' IEC60079: Part 5: Equipment protection by powder filling 'q' IEC60079: Part 6: Equipment protection by oil immersion 'o' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 13: Equipment protection by pressurized room "p" and artificially ventilated room "v" IEC60079: Part 15: Equipment protection by type of protection 'n' IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 25: Intrinsically safe electrical systems IEC60079: Part 26: Equipment with equipment protection level (EPL) Ga IEC60079: Part 27: Fieldbus intrinsically safe concept (FISCO) IEC60079: Part 28: Protection of equipment and transmission systems using optical radiation IEC60079: Part 29-1: Gas detectors - Performance requirements of detectors for flammable gases IEC60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC/IEEE60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' IEC/TS60079: Explosive atmospheres - Part 46: Equipment assemblies IEC/TS60079: Explosive atmospheres – Part 47: Equipment protection by 2-wire intrinsically safe Ethernet concept (2-WISE) IEC61241: Part 0: General requirements - Electrical apparatus for use in the presence of combustible dust IEC61241: Part 1: Protection by enclosures 'tD' IEC61241: Part 1-1: Electrical apparatus protected by enclosures and surface temperature limitation - Specification for apparatus IEC61241: Part 4: Type of protection 'pD' IEC61241: Part 11: Protection by intrinsic safety 'iD' IEC61241: Part 18: Protection by encapsulation 'mD' ISO80079: Part 36: Non-electrical equipment for explosive atmospheres - Basic method and requirements ISO80079: Part 37: Non-electrical equipment for explosive atmospheres - Non electrical type of protection constructional safety "c", control of ignition source "b", liquid immersion "k" DS2015/001A: IECEx Assessment and Certification of Equipment assemblies TR60079: Part 16: Artificial ventilation for the protection of analyser(s) houses |
|||
ITALY | IMQ | IMQ S.p.A. - Istituto Italiano del Marchio di Qualità | |
Contact
Mauro
Casari
Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 5: Equipment protection by powder filling 'q' IEC60079: Part 6: Equipment protection by oil immersion 'o' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 15: Equipment protection by type of protection 'n' IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 25: Intrinsically safe electrical systems IEC60079: Part 26: Equipment with equipment protection level (EPL) Ga IEC60079: Part 28: Protection of equipment and transmission systems using optical radiation IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' **IEC/TS60079: Explosive atmospheres- Electrical safety devices for the control of potential ignition sources for Ex-Equipment. ** This TS may be used for testing purposes but not for issuing an IECEx Certificate of Conformity IEC/TS60079: Explosive atmospheres - Part 46: Equipment assemblies IEC61241: Part 0: General requirements - Electrical apparatus for use in the presence of combustible dust IEC61241: Part 11: Protection by intrinsic safety 'iD' ISO80079: Part 36: Non-electrical equipment for explosive atmospheres - Basic method and requirements ISO80079: Part 37: Non-electrical equipment for explosive atmospheres - Non electrical type of protection constructional safety "c", control of ignition source "b", liquid immersion "k" DS2015/001A: IECEx Assessment and Certification of Equipment assemblies |
|||
JAPAN | TIIS | Technology Institution of Industrial Safety (TIIS) | |
Contact
Minari
Kogane
Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 2: Equipment protection by pressurized enclosures 'p' IEC60079: Part 5: Equipment protection by powder filling 'q' IEC60079: Part 6: Equipment protection by oil immersion 'o' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 13: Equipment protection by pressurized room "p" and artificially ventilated room "v" IEC60079: Part 15: Equipment protection by type of protection 'n' IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 25: Intrinsically safe electrical systems IEC60079: Part 26: Equipment with equipment protection level (EPL) Ga IEC60079: Part 28: Protection of equipment and transmission systems using optical radiation IEC60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC/IEEE60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' IEC60079: Part 33: Equipment protection by special protection 's' IEC/TS60079: Explosive atmospheres - Part 46: Equipment assemblies IEC62784: Vacuum cleaners and dust extractors providing equipment protection level Dc for the collection of combustible dusts - Particular requirements ISO80079: Part 36: Non-electrical equipment for explosive atmospheres - Basic method and requirements ISO80079: Part 37: Non-electrical equipment for explosive atmospheres - Non electrical type of protection constructional safety "c", control of ignition source "b", liquid immersion "k" Notes
|
|||
MALAYSIA | SIRIM | SIRIM QAS International SDN BHD (SRM) | |
Contact
Ariza
Mohd Yusof
Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 2: Equipment protection by pressurized enclosures 'p' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 13: Equipment protection by pressurized room "p" and artificially ventilated room "v" IEC60079: Part 15: Equipment protection by type of protection 'n' IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 25: Intrinsically safe electrical systems IEC/TS60079: Explosive atmospheres - Part 46: Equipment assemblies ISO80079: Part 36: Non-electrical equipment for explosive atmospheres - Basic method and requirements ISO80079: Part 37: Non-electrical equipment for explosive atmospheres - Non electrical type of protection constructional safety "c", control of ignition source "b", liquid immersion "k" |
|||
NETHERLANDS | CNEX | CNEX-Global B.V. | |
Contact
Fred
Lankamp
Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 2: Equipment protection by pressurized enclosures 'p' IEC60079: Part 5: Equipment protection by powder filling 'q' IEC60079: Part 6: Equipment protection by oil immersion 'o' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 13: Equipment protection by pressurized room "p" and artificially ventilated room "v" IEC60079: Part 15: Equipment protection by type of protection 'n' IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 25: Intrinsically safe electrical systems IEC60079: Part 26: Equipment with equipment protection level (EPL) Ga IEC60079: Part 27: Fieldbus intrinsically safe concept (FISCO) IEC60079: Part 28: Protection of equipment and transmission systems using optical radiation IEC60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' IEC60079: Part 33: Equipment protection by special protection 's' IEC/TS60079: Explosive atmospheres - Part 46: Equipment assemblies IEC61241: Part 0: General requirements - Electrical apparatus for use in the presence of combustible dust IEC61241: Part 1: Protection by enclosures 'tD' IEC61241: Part 4: Type of protection 'pD' IEC61241: Part 11: Protection by intrinsic safety 'iD' IEC61241: Part 18: Protection by encapsulation 'mD' IEC62086: Part 1: General and testing requirements - Electrical apparatus for explosive gas atmospheres – Electrical resistance trace heating ISO80079: Part 36: Non-electrical equipment for explosive atmospheres - Basic method and requirements ISO80079: Part 37: Non-electrical equipment for explosive atmospheres - Non electrical type of protection constructional safety "c", control of ignition source "b", liquid immersion "k" TR60079: Part 16: Artificial ventilation for the protection of analyser(s) houses |
|||
NETHERLANDS | DEKRA KEMA | DEKRA Certification B.V. (DEK, KEM) | |
Contact
Richard
Schuller
DEKRA Certification B.V. Postal Address +31 88 9683842 +31 88 9683100 Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 2: Equipment protection by pressurized enclosures 'p' IEC60079: Part 5: Equipment protection by powder filling 'q' IEC60079: Part 6: Equipment protection by oil immersion 'o' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 13: Equipment protection by pressurized room "p" and artificially ventilated room "v" IEC60079: Part 15: Equipment protection by type of protection 'n' IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 25: Intrinsically safe electrical systems IEC60079: Part 26: Equipment with equipment protection level (EPL) Ga IEC60079: Part 27: Fieldbus intrinsically safe concept (FISCO) IEC60079: Part 28: Protection of equipment and transmission systems using optical radiation IEC60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC/IEEE60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' IEC60079: Part 33: Equipment protection by special protection 's' IEC60079: Part 35-1: Caplights for use in mines susceptible to firedamp - General requirements - Construction and testing in relation to the risk of explosion IEC/TS60079: Part 40: Requirements for process sealing between flammable process fluids and electrical systems IEC/TS60079: Explosive atmospheres - Part 46: Equipment assemblies IEC/TS60079: Explosive atmospheres – Part 47: Equipment protection by 2-wire intrinsically safe Ethernet concept (2-WISE) IEC61241: Part 0: General requirements - Electrical apparatus for use in the presence of combustible dust IEC61241: Part 1: Protection by enclosures 'tD' IEC61241: Part 1-1: Electrical apparatus protected by enclosures and surface temperature limitation - Specification for apparatus IEC61241: Part 4: Type of protection 'pD' IEC61241: Part 11: Protection by intrinsic safety 'iD' IEC61241: Part 18: Protection by encapsulation 'mD' IEC62013: Part 1: General requirements - Construction and testing in relation to the risk of explosion - Caplights for use in mines susceptible to firedamp IEC62086: Part 1: General and testing requirements - Electrical apparatus for explosive gas atmospheres – Electrical resistance trace heating ISO80079: Part 36: Non-electrical equipment for explosive atmospheres - Basic method and requirements ISO80079: Part 37: Non-electrical equipment for explosive atmospheres - Non electrical type of protection constructional safety "c", control of ignition source "b", liquid immersion "k" DS2015/001A: IECEx Assessment and Certification of Equipment assemblies |
|||
NORWAY | Presafe/DNV | DNV Product Assurance AS (PRE, DNV, NEM) | |
Contact
Ståle
Sandstad
Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 2: Equipment protection by pressurized enclosures 'p' IEC60079: Part 5: Equipment protection by powder filling 'q' IEC60079: Part 6: Equipment protection by oil immersion 'o' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 13: Equipment protection by pressurized room "p" and artificially ventilated room "v" IEC60079: Part 15: Equipment protection by type of protection 'n' IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 25: Intrinsically safe electrical systems IEC60079: Part 26: Equipment with equipment protection level (EPL) Ga IEC60079: Part 27: Fieldbus intrinsically safe concept (FISCO) IEC60079: Part 28: Protection of equipment and transmission systems using optical radiation IEC60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' IEC60079: Part 35-1: Caplights for use in mines susceptible to firedamp - General requirements - Construction and testing in relation to the risk of explosion IEC/TS60079: Explosive atmospheres - Part 46: Equipment assemblies IEC61241: Part 0: General requirements - Electrical apparatus for use in the presence of combustible dust IEC61241: Part 1: Protection by enclosures 'tD' IEC61241: Part 4: Type of protection 'pD' IEC61241: Part 11: Protection by intrinsic safety 'iD' IEC61241: Part 18: Protection by encapsulation 'mD' IEC62013: Part 1: General requirements - Construction and testing in relation to the risk of explosion - Caplights for use in mines susceptible to firedamp ISO80079: Part 36: Non-electrical equipment for explosive atmospheres - Basic method and requirements ISO80079: Part 37: Non-electrical equipment for explosive atmospheres - Non electrical type of protection constructional safety "c", control of ignition source "b", liquid immersion "k" DS2015/001A: IECEx Assessment and Certification of Equipment assemblies |
|||
PEOPLES REPUBLIC OF CHINA | NEPSI | Shanghai Inspection and Testing Institute of Instruments and Automatic Systems Co., Ltd. (SITIIAS)/ National Supervision and Inspection Centre for Explosion Protection and Safety of Instrumentation (NEPSI) | |
Contact
Jianping
Xu
Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 2: Equipment protection by pressurized enclosures 'p' IEC60079: Part 5: Equipment protection by powder filling 'q' IEC60079: Part 6: Equipment protection by oil immersion 'o' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 13: Equipment protection by pressurized room "p" and artificially ventilated room "v" IEC60079: Part 15: Equipment protection by type of protection 'n' IEC60079: Part 16: Artificial ventilation for the protection of analyser (s) houses IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 25: Intrinsically safe electrical systems IEC60079: Part 26: Equipment with equipment protection level (EPL) Ga IEC60079: Part 27: Fieldbus intrinsically safe concept (FISCO) IEC60079: Part 28: Protection of equipment and transmission systems using optical radiation IEC60079: Part 29-1: Gas detectors - Performance requirements of detectors for flammable gases IEC60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' IEC60079: Part 33: Equipment protection by special protection 's' IEC/TS60079: Explosive atmospheres - Part 46: Equipment assemblies IEC/TS60079: Explosive atmospheres – Part 47: Equipment protection by 2-wire intrinsically safe Ethernet concept (2-WISE) IEC61241: Part 0: General requirements - Electrical apparatus for use in the presence of combustible dust IEC61241: Part 1: Protection by enclosures 'tD' IEC61241: Part 4: Type of protection 'pD' IEC61241: Part 11: Protection by intrinsic safety 'iD' IEC61241: Part 18: Protection by encapsulation 'mD' IEC62086: Part 1: General and testing requirements - Electrical apparatus for explosive gas atmospheres – Electrical resistance trace heating IEC62784: Vacuum cleaners and dust extractors providing equipment protection level Dc for the collection of combustible dusts - Particular requirements ISO80079: Part 36: Non-electrical equipment for explosive atmospheres - Basic method and requirements ISO80079: Part 37: Non-electrical equipment for explosive atmospheres - Non electrical type of protection constructional safety "c", control of ignition source "b", liquid immersion "k" |
|||
PEOPLES REPUBLIC OF CHINA | CNE | Nanyang Explosion Protected Electrical Apparatus Research Institute Co Ltd (CNE) | |
Contact
Wang
Jun
Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 2: Equipment protection by pressurized enclosures 'p' IEC60079: Part 5: Equipment protection by powder filling 'q' IEC60079: Part 6: Equipment protection by oil immersion 'o' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 13: Equipment protection by pressurized room "p" and artificially ventilated room "v" IEC60079: Part 15: Equipment protection by type of protection 'n' IEC60079: Part 16: Artificial ventilation for the protection of analyser (s) houses IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 25: Intrinsically safe electrical systems IEC60079: Part 26: Equipment with equipment protection level (EPL) Ga IEC60079: Part 27: Fieldbus intrinsically safe concept (FISCO) IEC60079: Part 28: Protection of equipment and transmission systems using optical radiation IEC60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC/IEEE60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' IEC60079: Part 33: Equipment protection by special protection 's' IEC/TS60079: Explosive atmospheres - Part 46: Equipment assemblies IEC61241: Part 0: General requirements - Electrical apparatus for use in the presence of combustible dust IEC61241: Part 1: Protection by enclosures 'tD' IEC61241: Part 4: Type of protection 'pD' IEC61241: Part 11: Protection by intrinsic safety 'iD' IEC61241: Part 18: Protection by encapsulation 'mD' IEC62086: Part 1: General and testing requirements - Electrical apparatus for explosive gas atmospheres – Electrical resistance trace heating ISO80079: Part 36: Non-electrical equipment for explosive atmospheres - Basic method and requirements ISO80079: Part 37: Non-electrical equipment for explosive atmospheres - Non electrical type of protection constructional safety "c", control of ignition source "b", liquid immersion "k" DS2015/001A: IECEx Assessment and Certification of Equipment assemblies Notes
|
|||
PEOPLES REPUBLIC OF CHINA | PCEC | PCEC (Tianjin) Certification Services Co., Ltd. (PCEC) | |
Contact
Mu
Yuqiang
+86-22-26689240-8205 Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 2: Equipment protection by pressurized enclosures 'p' IEC60079: Part 5: Equipment protection by powder filling 'q' IEC60079: Part 6: Equipment protection by oil immersion 'o' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 13: Equipment protection by pressurized room "p" and artificially ventilated room "v" IEC60079: Part 15: Equipment protection by type of protection 'n' IEC60079: Part 16: Artificial ventilation for the protection of analyser (s) houses IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 25: Intrinsically safe electrical systems IEC60079: Part 26: Equipment with equipment protection level (EPL) Ga IEC60079: Part 27: Fieldbus intrinsically safe concept (FISCO) IEC60079: Part 28: Protection of equipment and transmission systems using optical radiation IEC/IEEE60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' IEC60079: Part 33: Equipment protection by special protection 's' IEC61241: Part 1: Protection by enclosures 'tD' IEC61241: Part 4: Type of protection 'pD' IEC61241: Part 11: Protection by intrinsic safety 'iD' ISO80079: Part 36: Non-electrical equipment for explosive atmospheres - Basic method and requirements ISO80079: Part 37: Non-electrical equipment for explosive atmospheres - Non electrical type of protection constructional safety "c", control of ignition source "b", liquid immersion "k" |
|||
PEOPLES REPUBLIC OF CHINA | CQM | China Quality Mark Certification Group Co. Ltd (CQM) | |
Contact
Lu
Qiao
+86 21 52891711 Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 2: Equipment protection by pressurized enclosures 'p' IEC60079: Part 5: Equipment protection by powder filling 'q' IEC60079: Part 6: Equipment protection by oil immersion 'o' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 13: Equipment protection by pressurized room "p" and artificially ventilated room "v" IEC60079: Part 15: Equipment protection by type of protection 'n' IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 25: Intrinsically safe electrical systems IEC60079: Part 26: Equipment with equipment protection level (EPL) Ga IEC60079: Part 27: Fieldbus intrinsically safe concept (FISCO) IEC60079: Part 28: Protection of equipment and transmission systems using optical radiation IEC60079: Part 29-1: Gas detectors - Performance requirements of detectors for flammable gases IEC60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC/IEEE60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' IEC60079: Part 33: Equipment protection by special protection 's' IEC/TS60079: Explosive atmospheres - Part 46: Equipment assemblies IEC61241: Part 0: General requirements - Electrical apparatus for use in the presence of combustible dust IEC61241: Part 1: Protection by enclosures 'tD' IEC61241: Part 1-1: Electrical apparatus protected by enclosures and surface temperature limitation - Specification for apparatus IEC61241: Part 4: Type of protection 'pD' IEC61241: Part 11: Protection by intrinsic safety 'iD' IEC61241: Part 18: Protection by encapsulation 'mD' IEC62086: Part 1: General and testing requirements - Electrical apparatus for explosive gas atmospheres – Electrical resistance trace heating IEC62784: Vacuum cleaners and dust extractors providing equipment protection level Dc for the collection of combustible dusts - Particular requirements ISO80079: Part 36: Non-electrical equipment for explosive atmospheres - Basic method and requirements ISO80079: Part 37: Non-electrical equipment for explosive atmospheres - Non electrical type of protection constructional safety "c", control of ignition source "b", liquid immersion "k" DS2015/001A: IECEx Assessment and Certification of Equipment assemblies TR60079: Part 16: Artificial ventilation for the protection of analyser(s) houses Notes
|
|||
PEOPLES REPUBLIC OF CHINA | CQC | China Quality Certification Center | |
Contact
Bian
Jing
Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 2: Equipment protection by pressurized enclosures 'p' IEC60079: Part 5: Equipment protection by powder filling 'q' IEC60079: Part 6: Equipment protection by oil immersion 'o' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 13: Equipment protection by pressurized room "p" and artificially ventilated room "v" IEC60079: Part 15: Equipment protection by type of protection 'n' IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 25: Intrinsically safe electrical systems IEC60079: Part 26: Equipment with equipment protection level (EPL) Ga IEC60079: Part 28: Protection of equipment and transmission systems using optical radiation IEC60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' IEC61241: Part 0: General requirements - Electrical apparatus for use in the presence of combustible dust IEC61241: Part 1: Protection by enclosures 'tD' IEC61241: Part 4: Type of protection 'pD' IEC61241: Part 11: Protection by intrinsic safety 'iD' IEC61241: Part 18: Protection by encapsulation 'mD' |
|||
PEOPLES REPUBLIC OF CHINA | CMAC | China Mining Products Safety Approval and Certification Center | |
Contact
Li
Bo
008610 84264542 Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 25: Intrinsically safe electrical systems IEC60079: Part 26: Equipment with equipment protection level (EPL) Ga IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' |
|||
POLAND | OBAC | Osrodek Badan, Atestacji i Certyfikacji OBAC Sp. z o.o. | |
Contact
Piotr
Tarnawski
Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 2: Equipment protection by pressurized enclosures 'p' IEC60079: Part 5: Equipment protection by powder filling 'q' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 15: Equipment protection by type of protection 'n' IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 25: Intrinsically safe electrical systems IEC60079: Part 26: Equipment with equipment protection level (EPL) Ga IEC60079: Part 28: Protection of equipment and transmission systems using optical radiation IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' IEC/TS60079: Explosive atmospheres - Part 46: Equipment assemblies IEC61241: Part 4: Type of protection 'pD' ISO80079: Part 36: Non-electrical equipment for explosive atmospheres - Basic method and requirements ISO80079: Part 37: Non-electrical equipment for explosive atmospheres - Non electrical type of protection constructional safety "c", control of ignition source "b", liquid immersion "k" Notes
|
|||
POLAND | ICR | ICR Polska Sp. z o.o. | |
Contact
Jaroslaw
Zadrozny
Plac Przymierza, 6 Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' |
|||
POLAND | GIG | Central Mining Institute for Central Mining Institute - National Research Institute | |
Contact
Piotr
Madej
Glówny Instytut Górnictwa (GIG) Postal Address +48 32 3246 552 +48 32 32 24 931 Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 2: Equipment protection by pressurized enclosures 'p' IEC60079: Part 5: Equipment protection by powder filling 'q' IEC60079: Part 6: Equipment protection by oil immersion 'o' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 13: Equipment protection by pressurized room "p" and artificially ventilated room "v" IEC60079: Part 15: Equipment protection by type of protection 'n' IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 25: Intrinsically safe electrical systems IEC60079: Part 26: Equipment with equipment protection level (EPL) Ga IEC60079: Part 27: Fieldbus intrinsically safe concept (FISCO) IEC60079: Part 28: Protection of equipment and transmission systems using optical radiation IEC60079: Part 29-1: Gas detectors - Performance requirements of detectors for flammable gases IEC60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' IEC60079: Part 35-1: Caplights for use in mines susceptible to firedamp - General requirements - Construction and testing in relation to the risk of explosion IEC/TS60079: Explosive atmospheres - Part 46: Equipment assemblies IEC61241: Part 0: General requirements - Electrical apparatus for use in the presence of combustible dust IEC61241: Part 4: Type of protection 'pD' IEC61241: Part 11: Protection by intrinsic safety 'iD' IEC61241: Part 18: Protection by encapsulation 'mD' IEC62013: Part 1: General requirements - Construction and testing in relation to the risk of explosion - Caplights for use in mines susceptible to firedamp IEC62086: Part 1: General and testing requirements - Electrical apparatus for explosive gas atmospheres – Electrical resistance trace heating ISO/IEC80079: Explosive atmospheres - Part 49: Flame arresters - Performance requirements, test methods and limits of use ISO80079: Part 36: Non-electrical equipment for explosive atmospheres - Basic method and requirements ISO80079: Part 37: Non-electrical equipment for explosive atmospheres - Non electrical type of protection constructional safety "c", control of ignition source "b", liquid immersion "k" ISO16852: Flame arresters - Performance requirements, test methods and limits for use |
|||
POLAND | Hamilton | J.S. Hamilton Poland Sp. z o.o. (JSH) | |
Contact
Damian
Wróbel
ul. Wyzwolenia 14 Postal Address +48 32 730 82 00 Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 2: Equipment protection by pressurized enclosures 'p' IEC60079: Part 6: Equipment protection by oil immersion 'o' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 15: Equipment protection by type of protection 'n' IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 25: Intrinsically safe electrical systems IEC60079: Part 26: Equipment with equipment protection level (EPL) Ga IEC60079: Part 28: Protection of equipment and transmission systems using optical radiation IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' IEC/TS60079: Explosive atmospheres - Part 46: Equipment assemblies ISO80079: Part 36: Non-electrical equipment for explosive atmospheres - Basic method and requirements ISO80079: Part 37: Non-electrical equipment for explosive atmospheres - Non electrical type of protection constructional safety "c", control of ignition source "b", liquid immersion "k" |
|||
POLAND | KSCP | KSC POLAND Sp. z o.o. | |
Contact
Sanghe
Kim
Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 2: Equipment protection by pressurized enclosures 'p' IEC60079: Part 5: Equipment protection by powder filling 'q' IEC60079: Part 6: Equipment protection by oil immersion 'o' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 13: Equipment protection by pressurized room "p" and artificially ventilated room "v" IEC60079: Part 15: Equipment protection by type of protection 'n' IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 25: Intrinsically safe electrical systems IEC60079: Part 26: Equipment with equipment protection level (EPL) Ga IEC60079: Part 28: Protection of equipment and transmission systems using optical radiation IEC60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' IEC60079: Part 33: Equipment protection by special protection 's' IEC/TS60079: Explosive atmospheres - Part 46: Equipment assemblies ISO80079: Part 36: Non-electrical equipment for explosive atmospheres - Basic method and requirements ISO80079: Part 37: Non-electrical equipment for explosive atmospheres - Non electrical type of protection constructional safety "c", control of ignition source "b", liquid immersion "k" |
|||
REPUBLIC OF KOREA | KGS | Korea Gas Safety Corporation (KGS) | |
Contact
Changjoo
Seo
Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 2: Equipment protection by pressurized enclosures 'p' IEC60079: Part 6: Equipment protection by oil immersion 'o' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 15: Equipment protection by type of protection 'n' IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 26: Equipment with equipment protection level (EPL) Ga IEC60079: Part 28: Protection of equipment and transmission systems using optical radiation IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' IEC/TS60079: Explosive atmospheres - Part 46: Equipment assemblies ISO80079: Part 36: Non-electrical equipment for explosive atmospheres - Basic method and requirements ISO80079: Part 37: Non-electrical equipment for explosive atmospheres - Non electrical type of protection constructional safety "c", control of ignition source "b", liquid immersion "k" |
|||
REPUBLIC OF KOREA | KTL | Korea Testing Laboratory (KTL) | |
Contact
Dongjin
KIM
Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 2: Equipment protection by pressurized enclosures 'p' IEC60079: Part 5: Equipment protection by powder filling 'q' IEC60079: Part 6: Equipment protection by oil immersion 'o' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 13: Equipment protection by pressurized room "p" and artificially ventilated room "v" IEC60079: Part 15: Equipment protection by type of protection 'n' IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 26: Equipment with equipment protection level (EPL) Ga IEC60079: Part 27: Fieldbus intrinsically safe concept (FISCO) IEC60079: Part 28: Protection of equipment and transmission systems using optical radiation IEC/IEEE60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' IEC/TS60079: Explosive atmospheres - Part 46: Equipment assemblies ISO80079: Part 36: Non-electrical equipment for explosive atmospheres - Basic method and requirements ISO80079: Part 37: Non-electrical equipment for explosive atmospheres - Non electrical type of protection constructional safety "c", control of ignition source "b", liquid immersion "k" |
|||
REPUBLIC OF KOREA | KOSHA | Korea Occupational Safety and Health Agency (KOS) | |
Contact
Shin
Yong Woo
Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 2: Equipment protection by pressurized enclosures 'p' IEC60079: Part 5: Equipment protection by powder filling 'q' IEC60079: Part 6: Equipment protection by oil immersion 'o' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 15: Equipment protection by type of protection 'n' IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 26: Equipment with equipment protection level (EPL) Ga IEC60079: Part 28: Protection of equipment and transmission systems using optical radiation IEC60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC/IEEE60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' IEC61241: Part 0: General requirements - Electrical apparatus for use in the presence of combustible dust IEC61241: Part 1: Protection by enclosures 'tD' IEC61241: Part 1-1: Electrical apparatus protected by enclosures and surface temperature limitation - Specification for apparatus IEC61241: Part 4: Type of protection 'pD' IEC62086: Part 1: General and testing requirements - Electrical apparatus for explosive gas atmospheres – Electrical resistance trace heating |
|||
RUSSIA | NANIO CCVE | Certification Centre of explosion-proof and mine electrical equipment NANIO CCVE (CCVE) | |
Contact
Alexander
Zalogin
Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 2: Equipment protection by pressurized enclosures 'p' IEC60079: Part 5: Equipment protection by powder filling 'q' IEC60079: Part 6: Equipment protection by oil immersion 'o' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 13: Equipment protection by pressurized room "p" and artificially ventilated room "v" IEC60079: Part 15: Equipment protection by type of protection 'n' IEC60079: Part 16: Artificial ventilation for the protection of analyser (s) houses IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 25: Intrinsically safe electrical systems IEC60079: Part 26: Equipment with equipment protection level (EPL) Ga IEC60079: Part 27: Fieldbus intrinsically safe concept (FISCO) IEC60079: Part 28: Protection of equipment and transmission systems using optical radiation IEC60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC/IEEE60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' **IEC/TS60079: Edition 1.0 Explosive atmospheres - Part 32-1: Electrostatic Hazards - Guidance ** This TS may be used for testing purposes but not for issuing an IECEx Certificate of Conformity IEC60079: Part 33: Equipment protection by special protection 's' IEC60079: Part 35-1: Caplights for use in mines susceptible to firedamp - General requirements - Construction and testing in relation to the risk of explosion IEC60079: Part 35-2: Caplights for use in mines susceptible to firedamp - Performance IEC/TS60079: Part 39: Intrinsically safe systems with electronically controlled spark duration limitation IEC/TS60079: Part 40: Requirements for process sealing between flammable process fluids and electrical systems IEC/TS60079: Explosive atmospheres - Part 46: Equipment assemblies IEC61241: Part 0: General requirements - Electrical apparatus for use in the presence of combustible dust IEC61241: Part 1: Protection by enclosures 'tD' IEC61241: Part 1-1: Electrical apparatus protected by enclosures and surface temperature limitation - Specification for apparatus IEC61241: Part 4: Type of protection 'pD' IEC61241: Part 11: Protection by intrinsic safety 'iD' IEC61241: Part 18: Protection by encapsulation 'mD' IEC62013: Part 1: General requirements - Construction and testing in relation to the risk of explosion - Caplights for use in mines susceptible to firedamp IEC62013: Part 2: Performance and other safety-related matters - Caplights for use in mines susceptible to firedamp ISO80079: Part 36: Non-electrical equipment for explosive atmospheres - Basic method and requirements ISO80079: Part 37: Non-electrical equipment for explosive atmospheres - Non electrical type of protection constructional safety "c", control of ignition source "b", liquid immersion "k" DS2015/001A: IECEx Assessment and Certification of Equipment assemblies |
|||
SLOVENIA | SIQ | Slovenian Institute of Quality and Metrology | |
Contact
Matej
Debenc
+386 1 4778 100 Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 15: Equipment protection by type of protection 'n' IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 28: Protection of equipment and transmission systems using optical radiation IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' IEC60079: Part 35-1: Caplights for use in mines susceptible to firedamp - General requirements - Construction and testing in relation to the risk of explosion IEC/TS60079: Explosive atmospheres - Part 46: Equipment assemblies IEC62013: Part 1: General requirements - Construction and testing in relation to the risk of explosion - Caplights for use in mines susceptible to firedamp ISO80079: Part 36: Non-electrical equipment for explosive atmospheres - Basic method and requirements ISO80079: Part 37: Non-electrical equipment for explosive atmospheres - Non electrical type of protection constructional safety "c", control of ignition source "b", liquid immersion "k" DS2015/001A: IECEx Assessment and Certification of Equipment assemblies |
|||
SOUTH AFRICA | MASC | Mining and Surface Certification (ICS) | |
Contact
Francoius
du Toit
+27 (0) 12 653 7594 Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 5: Equipment protection by powder filling 'q' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 15: Equipment protection by type of protection 'n' IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 25: Intrinsically safe electrical systems IEC60079: Part 26: Equipment with equipment protection level (EPL) Ga IEC60079: Part 28: Protection of equipment and transmission systems using optical radiation IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' IEC60079: Part 33: Equipment protection by special protection 's' IEC60079: Part 35-1: Caplights for use in mines susceptible to firedamp - General requirements - Construction and testing in relation to the risk of explosion IEC60079: Part 35-2: Caplights for use in mines susceptible to firedamp - Performance IEC/TS60079: Explosive atmospheres - Part 46: Equipment assemblies ISO80079: Part 36: Non-electrical equipment for explosive atmospheres - Basic method and requirements ISO80079: Part 37: Non-electrical equipment for explosive atmospheres - Non electrical type of protection constructional safety "c", control of ignition source "b", liquid immersion "k" |
|||
SPAIN | LOM | LABORATORIO OFICIAL J.M. MADARIAGA | |
Contact
Natalia
Vazquez
LOM Laboratorio Oficial J.M. Madariaga +34 910679825 Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 2: Equipment protection by pressurized enclosures 'p' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 15: Equipment protection by type of protection 'n' IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 25: Intrinsically safe electrical systems IEC60079: Part 26: Equipment with equipment protection level (EPL) Ga IEC60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC/IEEE60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' IEC60079: Part 35-1: Caplights for use in mines susceptible to firedamp - General requirements - Construction and testing in relation to the risk of explosion IEC/TS60079: Explosive atmospheres - Part 46: Equipment assemblies IEC61241: Part 4: Type of protection 'pD' IEC62013: Part 1: General requirements - Construction and testing in relation to the risk of explosion - Caplights for use in mines susceptible to firedamp ISO80079: Part 36: Non-electrical equipment for explosive atmospheres - Basic method and requirements ISO80079: Part 37: Non-electrical equipment for explosive atmospheres - Non electrical type of protection constructional safety "c", control of ignition source "b", liquid immersion "k" |
|||
SWEDEN | RISE | RISE Research Institutes of Sweden AB (RISE & SP) | |
Contact
Hussni
Al-Farra
+46 10 516 53 96 Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 2: Equipment protection by pressurized enclosures 'p' IEC60079: Part 5: Equipment protection by powder filling 'q' IEC60079: Part 6: Equipment protection by oil immersion 'o' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 15: Equipment protection by type of protection 'n' IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 25: Intrinsically safe electrical systems IEC60079: Part 26: Equipment with equipment protection level (EPL) Ga IEC60079: Part 27: Fieldbus intrinsically safe concept (FISCO) IEC60079: Part 28: Protection of equipment and transmission systems using optical radiation IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' IEC61241: Part 0: General requirements - Electrical apparatus for use in the presence of combustible dust IEC61241: Part 1: Protection by enclosures 'tD' IEC61241: Part 1-1: Electrical apparatus protected by enclosures and surface temperature limitation - Specification for apparatus IEC61241: Part 4: Type of protection 'pD' IEC61241: Part 11: Protection by intrinsic safety 'iD' IEC61241: Part 18: Protection by encapsulation 'mD' IEC62784: Vacuum cleaners and dust extractors providing equipment protection level Dc for the collection of combustible dusts - Particular requirements ISO80079: Part 36: Non-electrical equipment for explosive atmospheres - Basic method and requirements ISO80079: Part 37: Non-electrical equipment for explosive atmospheres - Non electrical type of protection constructional safety "c", control of ignition source "b", liquid immersion "k" ISO16852: Flame arresters - Performance requirements, test methods and limits for use Notes
Note: IEC 60079-28 Part 28: Protection of equipment and transmission systems using optical radiation (Restricted to covering “op is” according to 5.2.4) |
|||
SWITZERLAND | SEV | Eurofins Electric & Electronic Product Testing AG | |
Contact
Holger
Schaffer
+49 33631 888-901 Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 2: Equipment protection by pressurized enclosures 'p' IEC60079: Part 5: Equipment protection by powder filling 'q' IEC60079: Part 6: Equipment protection by oil immersion 'o' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 15: Equipment protection by type of protection 'n' IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 26: Equipment with equipment protection level (EPL) Ga IEC60079: Part 28: Protection of equipment and transmission systems using optical radiation IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' IEC/TS60079: Part 40: Requirements for process sealing between flammable process fluids and electrical systems IEC/TS60079: Explosive atmospheres - Part 46: Equipment assemblies IEC/TS60079: Explosive atmospheres – Part 47: Equipment protection by 2-wire intrinsically safe Ethernet concept (2-WISE) IEC61241: Part 0: General requirements - Electrical apparatus for use in the presence of combustible dust IEC61241: Part 1: Protection by enclosures 'tD' IEC61241: Part 1-1: Electrical apparatus protected by enclosures and surface temperature limitation - Specification for apparatus IEC61241: Part 4: Type of protection 'pD' IEC61241: Part 11: Protection by intrinsic safety 'iD' IEC61241: Part 18: Protection by encapsulation 'mD' ISO80079: Part 36: Non-electrical equipment for explosive atmospheres - Basic method and requirements ISO80079: Part 37: Non-electrical equipment for explosive atmospheres - Non electrical type of protection constructional safety "c", control of ignition source "b", liquid immersion "k" DS2015/001A: IECEx Assessment and Certification of Equipment assemblies Notes
|
|||
TÜRKIYE | SZUT | SZUTEST Uygunluk Değerlandirme A.Ş. | |
Contact
Ali
Kiremitci
Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 2: Equipment protection by pressurized enclosures 'p' IEC60079: Part 6: Equipment protection by oil immersion 'o' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 15: Equipment protection by type of protection 'n' IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 26: Equipment with equipment protection level (EPL) Ga IEC60079: Part 28: Protection of equipment and transmission systems using optical radiation IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' IEC/TS60079: Explosive atmospheres - Part 46: Equipment assemblies ISO80079: Part 36: Non-electrical equipment for explosive atmospheres - Basic method and requirements ISO80079: Part 37: Non-electrical equipment for explosive atmospheres - Non electrical type of protection constructional safety "c", control of ignition source "b", liquid immersion "k" |
|||
UNITED KINGDOM | ExVeritas | ExVeritas Limited (EXV) | |
Contact
Sean
Clarke
Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 2: Equipment protection by pressurized enclosures 'p' IEC60079: Part 5: Equipment protection by powder filling 'q' IEC60079: Part 6: Equipment protection by oil immersion 'o' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 13: Equipment protection by pressurized room "p" and artificially ventilated room "v" IEC60079: Part 15: Equipment protection by type of protection 'n' IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 25: Intrinsically safe electrical systems IEC60079: Part 26: Equipment with equipment protection level (EPL) Ga IEC60079: Part 27: Fieldbus intrinsically safe concept (FISCO) IEC60079: Part 28: Protection of equipment and transmission systems using optical radiation IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' IEC60079: Part 33: Equipment protection by special protection 's' IEC/TS60079: Explosive atmospheres - Part 46: Equipment assemblies IEC/TS60079: Explosive atmospheres – Part 47: Equipment protection by 2-wire intrinsically safe Ethernet concept (2-WISE) IEC61241: Part 0: General requirements - Electrical apparatus for use in the presence of combustible dust IEC61241: Part 1: Protection by enclosures 'tD' IEC61241: Part 1-1: Electrical apparatus protected by enclosures and surface temperature limitation - Specification for apparatus IEC61241: Part 4: Type of protection 'pD' IEC61241: Part 18: Protection by encapsulation 'mD' ISO80079: Part 36: Non-electrical equipment for explosive atmospheres - Basic method and requirements ISO80079: Part 37: Non-electrical equipment for explosive atmospheres - Non electrical type of protection constructional safety "c", control of ignition source "b", liquid immersion "k" |
|||
UNITED KINGDOM | SGS | SGS UK Ltd | |
Contact
Glenn
Manifiold
Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 2: Equipment protection by pressurized enclosures 'p' IEC60079: Part 5: Equipment protection by powder filling 'q' IEC60079: Part 6: Equipment protection by oil immersion 'o' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 13: Equipment protection by pressurized room "p" and artificially ventilated room "v" IEC60079: Part 15: Equipment protection by type of protection 'n' IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 25: Intrinsically safe electrical systems IEC60079: Part 26: Equipment with equipment protection level (EPL) Ga IEC60079: Part 27: Fieldbus intrinsically safe concept (FISCO) IEC60079: Part 28: Protection of equipment and transmission systems using optical radiation IEC60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC/IEEE60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' IEC60079: Part 33: Equipment protection by special protection 's' IEC60079: Part 35-1: Caplights for use in mines susceptible to firedamp - General requirements - Construction and testing in relation to the risk of explosion IEC60079: Part 35-2: Caplights for use in mines susceptible to firedamp - Performance IEC/TS60079: Explosive atmospheres - Part 46: Equipment assemblies IEC61241: Part 0: General requirements - Electrical apparatus for use in the presence of combustible dust IEC61241: Part 1: Protection by enclosures 'tD' IEC61241: Part 1-1: Electrical apparatus protected by enclosures and surface temperature limitation - Specification for apparatus IEC61241: Part 11: Protection by intrinsic safety 'iD' IEC61241: Part 18: Protection by encapsulation 'mD' IEC62013: Part 1: General requirements - Construction and testing in relation to the risk of explosion - Caplights for use in mines susceptible to firedamp IEC62013: Part 2: Performance and other safety-related matters - Caplights for use in mines susceptible to firedamp IEC62086: Part 1: General and testing requirements - Electrical apparatus for explosive gas atmospheres – Electrical resistance trace heating ISO80079: Part 36: Non-electrical equipment for explosive atmospheres - Basic method and requirements ISO80079: Part 37: Non-electrical equipment for explosive atmospheres - Non electrical type of protection constructional safety "c", control of ignition source "b", liquid immersion "k" DS2015/001A: IECEx Assessment and Certification of Equipment assemblies Notes
|
|||
UNITED KINGDOM | ITS | Intertek Testing & Certification Limited UK (ITS) | |
Contact
Adrian
Smart
+44 1372370900 Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 2: Equipment protection by pressurized enclosures 'p' IEC60079: Part 5: Equipment protection by powder filling 'q' IEC60079: Part 6: Equipment protection by oil immersion 'o' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 13: Equipment protection by pressurized room "p" and artificially ventilated room "v" IEC60079: Part 15: Equipment protection by type of protection 'n' IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 25: Intrinsically safe electrical systems IEC60079: Part 26: Equipment with equipment protection level (EPL) Ga IEC60079: Part 27: Fieldbus intrinsically safe concept (FISCO) IEC60079: Part 28: Protection of equipment and transmission systems using optical radiation IEC60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC/IEEE60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' IEC60079: Part 33: Equipment protection by special protection 's' IEC60079: Part 35-1: Caplights for use in mines susceptible to firedamp - General requirements - Construction and testing in relation to the risk of explosion IEC/TS60079: Explosive atmospheres - Part 46: Equipment assemblies IEC61241: Part 0: General requirements - Electrical apparatus for use in the presence of combustible dust IEC61241: Part 1: Protection by enclosures 'tD' IEC61241: Part 1-1: Electrical apparatus protected by enclosures and surface temperature limitation - Specification for apparatus IEC61241: Part 4: Type of protection 'pD' IEC61241: Part 11: Protection by intrinsic safety 'iD' IEC61241: Part 18: Protection by encapsulation 'mD' IEC62013: Part 1: General requirements - Construction and testing in relation to the risk of explosion - Caplights for use in mines susceptible to firedamp IEC62013: Part 2: Performance and other safety-related matters - Caplights for use in mines susceptible to firedamp IEC62086: Part 1: General and testing requirements - Electrical apparatus for explosive gas atmospheres – Electrical resistance trace heating ISO80079: Part 36: Non-electrical equipment for explosive atmospheres - Basic method and requirements ISO80079: Part 37: Non-electrical equipment for explosive atmospheres - Non electrical type of protection constructional safety "c", control of ignition source "b", liquid immersion "k" DS2015/001A: IECEx Assessment and Certification of Equipment assemblies Notes
|
|||
UNITED KINGDOM | FM EU | FM Approvals (FME) | |
Contact
Andrew
Was
Voyager Place Dir: +44 (0) 1753 750475 or +44 (0) 1753 750000 +44 (0) 1753 868700 Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 2: Equipment protection by pressurized enclosures 'p' IEC60079: Part 5: Equipment protection by powder filling 'q' IEC60079: Part 6: Equipment protection by oil immersion 'o' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 15: Equipment protection by type of protection 'n' IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 25: Intrinsically safe electrical systems IEC60079: Part 26: Equipment with equipment protection level (EPL) Ga IEC60079: Part 27: Fieldbus intrinsically safe concept (FISCO) IEC60079: Part 28: Protection of equipment and transmission systems using optical radiation IEC60079: Part 29-1: Gas detectors - Performance requirements of detectors for flammable gases IEC60079: Part 29-4: Gas detectors - Performance requirements of open path detectors for flammable gases IEC60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC/IEEE60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' IEC/TS60079: Part 40: Requirements for process sealing between flammable process fluids and electrical systems IEC/TS60079: Explosive atmospheres – Part 47: Equipment protection by 2-wire intrinsically safe Ethernet concept (2-WISE) IEC61779: Part 1: General requirements and test methods - Electrical apparatus for the detection and measurement of flammable gases IEC61779: Part 4: Performance requirements for group II apparatus indicating a volume fraction up to 100% lower explosive limit IEC61779: Part 5: Performance requirements for group II apparatus indicating a volume fraction up to 100% gas IEC61241: Part 0: General requirements - Electrical apparatus for use in the presence of combustible dust IEC61241: Part 1: Protection by enclosures 'tD' IEC61241: Part 1-1: Electrical apparatus protected by enclosures and surface temperature limitation - Specification for apparatus IEC61241: Part 4: Type of protection 'pD' IEC61241: Part 11: Protection by intrinsic safety 'iD' IEC61241: Part 18: Protection by encapsulation 'mD' IEC62086: Part 1: General and testing requirements - Electrical apparatus for explosive gas atmospheres – Electrical resistance trace heating IEC62990: Workplace atmospheres – Part 1: Gas detectors – Performance requirements of detectors for toxic gases ISO80079: Part 36: Non-electrical equipment for explosive atmospheres - Basic method and requirements ISO80079: Part 37: Non-electrical equipment for explosive atmospheres - Non electrical type of protection constructional safety "c", control of ignition source "b", liquid immersion "k" Notes
|
|||
UNITED KINGDOM | EMT | Element Materials Technology (EMT, TRC) | |
Contact
Stephen
Winsor
Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 2: Equipment protection by pressurized enclosures 'p' IEC60079: Part 6: Equipment protection by oil immersion 'o' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 15: Equipment protection by type of protection 'n' IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 26: Equipment with equipment protection level (EPL) Ga IEC60079: Part 28: Protection of equipment and transmission systems using optical radiation IEC60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' IEC/TS60079: Explosive atmospheres - Part 46: Equipment assemblies IEC61241: Part 0: General requirements - Electrical apparatus for use in the presence of combustible dust IEC61241: Part 1: Protection by enclosures 'tD' IEC61241: Part 4: Type of protection 'pD' IEC61241: Part 11: Protection by intrinsic safety 'iD' IEC61241: Part 18: Protection by encapsulation 'mD' ISO80079: Part 36: Non-electrical equipment for explosive atmospheres - Basic method and requirements ISO80079: Part 37: Non-electrical equipment for explosive atmospheres - Non electrical type of protection constructional safety "c", control of ignition source "b", liquid immersion "k" DS2015/001A: IECEx Assessment and Certification of Equipment assemblies |
|||
UNITED KINGDOM | CML | Eurofins E&E CML Limited (CML) | |
Contact
Stelios
Roumbedakis
+44 (0)151 559 1160 Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 2: Equipment protection by pressurized enclosures 'p' IEC60079: Part 5: Equipment protection by powder filling 'q' IEC60079: Part 6: Equipment protection by oil immersion 'o' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 13: Equipment protection by pressurized room "p" and artificially ventilated room "v" IEC60079: Part 15: Equipment protection by type of protection 'n' IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 25: Intrinsically safe electrical systems IEC60079: Part 26: Equipment with equipment protection level (EPL) Ga IEC60079: Part 27: Fieldbus intrinsically safe concept (FISCO) IEC60079: Part 28: Protection of equipment and transmission systems using optical radiation IEC60079: Part 29-1: Gas detectors - Performance requirements of detectors for flammable gases IEC60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC/IEEE60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' IEC60079: Part 33: Equipment protection by special protection 's' IEC60079: Part 35-1: Caplights for use in mines susceptible to firedamp - General requirements - Construction and testing in relation to the risk of explosion IEC60079: Part 35-2: Caplights for use in mines susceptible to firedamp - Performance IEC/TS60079: Part 39: Intrinsically safe systems with electronically controlled spark duration limitation IEC/TS60079: Part 40: Requirements for process sealing between flammable process fluids and electrical systems IEC/TS60079: Explosive atmospheres - Part 46: Equipment assemblies IEC/TS60079: Explosive atmospheres – Part 47: Equipment protection by 2-wire intrinsically safe Ethernet concept (2-WISE) IEC61241: Part 0: General requirements - Electrical apparatus for use in the presence of combustible dust IEC61241: Part 1: Protection by enclosures 'tD' IEC61241: Part 4: Type of protection 'pD' IEC61241: Part 11: Protection by intrinsic safety 'iD' IEC61241: Part 18: Protection by encapsulation 'mD' IEC62013: Part 1: General requirements - Construction and testing in relation to the risk of explosion - Caplights for use in mines susceptible to firedamp ISO80079: Part 36: Non-electrical equipment for explosive atmospheres - Basic method and requirements ISO80079: Part 37: Non-electrical equipment for explosive atmospheres - Non electrical type of protection constructional safety "c", control of ignition source "b", liquid immersion "k" |
|||
UNITED KINGDOM | CSAE | CSA Group Testing UK Ltd (previously SIRA, now manages all certs & rpts issued with SIR ID) | |
Contact
Bryn
Spencer
Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 2: Equipment protection by pressurized enclosures 'p' IEC60079: Part 5: Equipment protection by powder filling 'q' IEC60079: Part 6: Equipment protection by oil immersion 'o' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 13: Equipment protection by pressurized room "p" and artificially ventilated room "v" IEC60079: Part 15: Equipment protection by type of protection 'n' IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 25: Intrinsically safe electrical systems IEC60079: Part 26: Equipment with equipment protection level (EPL) Ga IEC60079: Part 27: Fieldbus intrinsically safe concept (FISCO) IEC60079: Part 28: Protection of equipment and transmission systems using optical radiation IEC60079: Part 29-1: Gas detectors - Performance requirements of detectors for flammable gases IEC60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC/IEEE60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' IEC60079: Part 35-1: Caplights for use in mines susceptible to firedamp - General requirements - Construction and testing in relation to the risk of explosion IEC/TS60079: Part 40: Requirements for process sealing between flammable process fluids and electrical systems IEC/TS60079: Explosive atmospheres - Part 46: Equipment assemblies IEC61779: Part 1: General requirements and test methods - Electrical apparatus for the detection and measurement of flammable gases IEC61779: Part 2: Performance requirements for group I apparatus indicating a volume fraction up to 5% methane in air IEC61779: Part 3: Performance requirements for group I apparatus indicating a volume fraction up to 100% methane in air IEC61779: Part 4: Performance requirements for group II apparatus indicating a volume fraction up to 100% lower explosive limit IEC61779: Part 5: Performance requirements for group II apparatus indicating a volume fraction up to 100% gas IEC61241: Part 0: General requirements - Electrical apparatus for use in the presence of combustible dust IEC61241: Part 1: Protection by enclosures 'tD' IEC61241: Part 1-1: Electrical apparatus protected by enclosures and surface temperature limitation - Specification for apparatus IEC61241: Part 4: Type of protection 'pD' IEC61241: Part 11: Protection by intrinsic safety 'iD' IEC61241: Part 18: Protection by encapsulation 'mD' IEC62013: Part 1: General requirements - Construction and testing in relation to the risk of explosion - Caplights for use in mines susceptible to firedamp IEC62086: Part 1: General and testing requirements - Electrical apparatus for explosive gas atmospheres – Electrical resistance trace heating ISO80079: Part 36: Non-electrical equipment for explosive atmospheres - Basic method and requirements ISO80079: Part 37: Non-electrical equipment for explosive atmospheres - Non electrical type of protection constructional safety "c", control of ignition source "b", liquid immersion "k" |
|||
UNITED STATES OF AMERICA | UL | UL Solutions (US) | |
Contact
Katy
Holdredge
+1 847 664 2321 Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 2: Equipment protection by pressurized enclosures 'p' IEC60079: Part 5: Equipment protection by powder filling 'q' IEC60079: Part 6: Equipment protection by oil immersion 'o' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 13: Equipment protection by pressurized room "p" and artificially ventilated room "v" IEC60079: Part 15: Equipment protection by type of protection 'n' IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 25: Intrinsically safe electrical systems IEC60079: Part 26: Equipment with equipment protection level (EPL) Ga IEC60079: Part 27: Fieldbus intrinsically safe concept (FISCO) IEC60079: Part 28: Protection of equipment and transmission systems using optical radiation IEC60079: Part 29-1: Gas detectors - Performance requirements of detectors for flammable gases IEC60079: Part 29-4: Gas detectors - Performance requirements of open path detectors for flammable gases IEC60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC/IEEE60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' IEC60079: Part 33: Equipment protection by special protection 's' IEC/TS60079: Part 40: Requirements for process sealing between flammable process fluids and electrical systems IEC/TS60079: Explosive atmospheres - Part 46: Equipment assemblies IEC/TS60079: Explosive atmospheres – Part 47: Equipment protection by 2-wire intrinsically safe Ethernet concept (2-WISE) IEC61241: Part 0: General requirements - Electrical apparatus for use in the presence of combustible dust IEC61241: Part 1: Protection by enclosures 'tD' IEC61241: Part 1-1: Electrical apparatus protected by enclosures and surface temperature limitation - Specification for apparatus IEC61241: Part 4: Type of protection 'pD' IEC61241: Part 11: Protection by intrinsic safety 'iD' IEC61241: Part 18: Protection by encapsulation 'mD' IEC62086: Part 1: General and testing requirements - Electrical apparatus for explosive gas atmospheres – Electrical resistance trace heating IEC62784: Vacuum cleaners and dust extractors providing equipment protection level Dc for the collection of combustible dusts - Particular requirements ISO80079: Part 36: Non-electrical equipment for explosive atmospheres - Basic method and requirements ISO80079: Part 37: Non-electrical equipment for explosive atmospheres - Non electrical type of protection constructional safety "c", control of ignition source "b", liquid immersion "k" DS2015/001A: IECEx Assessment and Certification of Equipment assemblies |
|||
UNITED STATES OF AMERICA | SNA | SGS North America inc. | |
Contact
Vijayaraghavan
Rangarajan
Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 2: Equipment protection by pressurized enclosures 'p' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 15: Equipment protection by type of protection 'n' IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 28: Protection of equipment and transmission systems using optical radiation IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' |
|||
UNITED STATES OF AMERICA | ITS US | Intertek Testing Services NA, Inc. US (ETL) | |
Contact
Bill
Fiske
Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 2: Equipment protection by pressurized enclosures 'p' IEC60079: Part 5: Equipment protection by powder filling 'q' IEC60079: Part 6: Equipment protection by oil immersion 'o' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 13: Equipment protection by pressurized room "p" and artificially ventilated room "v" IEC60079: Part 15: Equipment protection by type of protection 'n' IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 25: Intrinsically safe electrical systems IEC60079: Part 26: Equipment with equipment protection level (EPL) Ga IEC60079: Part 28: Protection of equipment and transmission systems using optical radiation IEC60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC/IEEE60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' IEC/TS60079: Part 40: Requirements for process sealing between flammable process fluids and electrical systems IEC/TS60079: Explosive atmospheres - Part 46: Equipment assemblies IEC61241: Part 0: General requirements - Electrical apparatus for use in the presence of combustible dust IEC61241: Part 1: Protection by enclosures 'tD' IEC61241: Part 1-1: Electrical apparatus protected by enclosures and surface temperature limitation - Specification for apparatus IEC61241: Part 4: Type of protection 'pD' IECExOD 290: IECEx Certified Equipment Scheme - Harmonized procedures for IECEx certification of equipment, components and systems associated with the production, dispensing and use of gaseous hydrogen ISO19880: Gaseous hydrogen - Fuelling stations Part 1 General requirements ISO80079: Part 36: Non-electrical equipment for explosive atmospheres - Basic method and requirements ISO80079: Part 37: Non-electrical equipment for explosive atmospheres - Non electrical type of protection constructional safety "c", control of ignition source "b", liquid immersion "k" Notes
|
|||
UNITED STATES OF AMERICA | FM | FM Approvals LLC (FMG) | |
Contact
James
Marquedant
1 Technology Way Postal Address +1 (781) 255 4825 Scope
IEC60079: Part 0: Equipment - General requirements IEC60079: Part 1: Equipment protection by flameproof enclosures 'd' IEC60079: Part 2: Equipment protection by pressurized enclosures 'p' IEC60079: Part 5: Equipment protection by powder filling 'q' IEC60079: Part 6: Equipment protection by oil immersion 'o' IEC60079: Part 7: Equipment protection by increased safety 'e' IEC60079: Part 11: Equipment protection by intrinsic safety 'i' IEC60079: Part 15: Equipment protection by type of protection 'n' IEC60079: Part 18: Equipment protection by encapsulation “m” IEC60079: Part 25: Intrinsically safe electrical systems IEC60079: Part 26: Equipment with equipment protection level (EPL) Ga IEC60079: Part 27: Fieldbus intrinsically safe concept (FISCO) IEC60079: Part 28: Protection of equipment and transmission systems using optical radiation IEC60079: Part 29-1: Gas detectors - Performance requirements of detectors for flammable gases IEC60079: Part 29-4: Gas detectors - Performance requirements of open path detectors for flammable gases IEC60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC/IEEE60079: Part 30-1: Electrical resistance trace heating - General and testing requirements IEC60079: Part 31: Equipment dust ignition protection by enclosure 't' IEC/TS60079: Part 40: Requirements for process sealing between flammable process fluids and electrical systems IEC/TS60079: Explosive atmospheres – Part 47: Equipment protection by 2-wire intrinsically safe Ethernet concept (2-WISE) IEC61779: Part 1: General requirements and test methods - Electrical apparatus for the detection and measurement of flammable gases IEC61779: Part 4: Performance requirements for group II apparatus indicating a volume fraction up to 100% lower explosive limit IEC61779: Part 5: Performance requirements for group II apparatus indicating a volume fraction up to 100% gas IEC61241: Part 0: General requirements - Electrical apparatus for use in the presence of combustible dust IEC61241: Part 1: Protection by enclosures 'tD' IEC61241: Part 1-1: Electrical apparatus protected by enclosures and surface temperature limitation - Specification for apparatus IEC61241: Part 4: Type of protection 'pD' IEC61241: Part 11: Protection by intrinsic safety 'iD' IEC61241: Part 18: Protection by encapsulation 'mD' IEC62086: Part 1: General and testing requirements - Electrical apparatus for explosive gas atmospheres – Electrical resistance trace heating IEC62990: Workplace atmospheres – Part 1: Gas detectors – Performance requirements of detectors for toxic gases ISO80079: Part 36: Non-electrical equipment for explosive atmospheres - Basic method and requirements ISO80079: Part 37: Non-electrical equipment for explosive atmospheres - Non electrical type of protection constructional safety "c", control of ignition source "b", liquid immersion "k" |