*Updated 170919
*Zip file containing meeting documents and linked agenda ExTAG_465A 3.0MB
(extract to a folder, then open Agenda ExTAG_465A which contains hypertext links to the documents referenced in the agenda)
Agenda Item | Document Number | Title |
---|---|---|
Day 1 Sept 25th | ExTAG/479A/Inf |
IECEx ExTAG and Assessor Training Workshop to be held Monday 25th September 2017 |
2.0 | ExTAG/465A/DA |
The Nineteenth Meeting of the ExTAG to be held in Washington D.C. (USA) on 26th September 2017 Draft Agenda |
3.1 | ExTAG/446/R |
Report of the Eighteenth Meeting of the ExTAG- Umhlanga, South Africa |
3.2 | ExTAG/466/R |
Status Report on Action Items from the 2016 ExTAG Umhlanga Meeting |
4 | ExTAG/459/Inf |
Term of Office –ExTAG Chair |
6.2 | ExMC/1290/CD |
Discussion Paper - Consideration of new Standard IEC 62784 |
7.5 | ExMC/1259/CD |
Draft new Operational Document - Requirements when dealing with the Suspension or Cancellation of IECEx Certificates of Conformity issued under the IECEx 02 Certified Equipment Scheme |
7.7 | ExTAG/480/CD |
Preliminary Draft Decision Sheet – 3D Printing |
7.9 | ExTAG/482/CD |
Draft Revision of DS 2015/016 Testing of thermocatalytic sensors with Ex ia IIC marking |
7.9 | DS 2015/016 |
Testing of thermocatalytic sensors with Ex ia IIC marking |
8.1 | ExTAG/472A/R |
Report from ExTAG Working Group 01 (WG01): Preparation of assessment and test report forms (ExTRs) |
8.1 | ExMC/1296/CD |
GB Proposal concerning a change to the ExTR Cover regarding the name and address of the Laboratory. |
8.2 | IECEx OD 017 Ed.5 |
Operational Document - Drawing and documentation Guidance for IEC Ex Certification – for use by Manufacturers and ExTLS |
8.3 | IECEx OD 202 Ed 1.0 |
Operational Document - IECEx Proficiency Testing Program |
8.3 | ExTAG/474/R |
Report from Tim Krause, Convenor ExTAG WG 10, Proficiency Testing |
8.3 | ExMC/1292/DV |
Proposed Revised Edition of IECEx Operational Document OD 202 – IECEx Proficiency Testing Program (Ex PTP) |
8.4 | IECEx OD 207 Ed.1.0 |
Operational Document - Guidance on the Retention of Records |
9.3 | IECEx OD 035 Ed.2.1 |
Operational Document - A procedure to generate, discuss, report and publish ExTAG Decision Sheets |
9.4 | DS 2017/001 |
Cable transit or entry devices according IEC 60079-0 |
9.5 | DS 2017/002 |
Guidance on issuance of QARs when products are manufactured at multiple sites |
9.6 | DS 2016/002 |
Application of Failure Analysis such as FMEA in intrinsic safety “i” |
9.7 | ExTAG/464/CC |
Compilation of comments and observations on ExTAG/451/CD Draft ExTAG Decision Sheet – Application of IEC 60079-28 |
9.7 | DS 2017/003 |
Applicability of IEC 60079-28, especially regarding LED light sources |
10.1 | ExTAG/406A/CD |
Draft Revision to Decision Sheet DS 2012/005 - Inclusion of an IP rating as part of the marking and certificate |
10.2 | ExTAG/453A/CD |
Draft ExTAG Decision Sheet - Terminal Ratings in General Purpose Junction Boxes |
10.2 | ExTAG/467/CC |
Compilation of comments and observations on ExTAG/453/CD Draft ExTAG Decision Sheet - Terminal Ratings in General Purpose Junction Boxes |
10.3 | ExTAG/468/CD |
Draft Decision Sheet - Clarification on the use of legacy data |
10.4 | ExTAG/447/CD |
Draft ExTAG Decision Sheet – Marking of combined Electrical/Non Electrical Equipment |
10.4 | ExTAG/447A/CD |
Revised Draft ExTAG Decision Sheet – Marking of combined Electrical/Non Electrical Equipment |
10.4 | ExTAG/469/CC |
Compilation of comments and observations on ExTAG/447/CD Draft Decision Sheet – Marking of combined Electrical/Non Electrical Equipment |
10.5 | ExTAG/452/CD |
Draft ExTAG Decision Sheet – Requirements for gas sensors using the “da” level of protection |
10.5 | ExTAG/470/CC |
Compilation of comments and observations on ExTAG/452/CD Draft ExTAG Decision Sheet – Requirements for gas sensors using the “da” level of protection |
10.6 | ExTAG/456A/CD |
Draft ExTAG Decision Sheet – Temperature rise of the conductor bar for terminals in Level of Protection “eb” according to IEC 60079-7 |
10.6 | ExTAG/463/CC |
Compilation of comments and observations on ExTAG/456/CD Draft ExTAG Decision Sheet – Temperature rise of the conductor bar for terminals in Level of Protection “eb” according to IEC 60079-7 |
10.7 | ExTAG/457A/CD |
Revised Draft ExTAG Decision Sheet – Guidance on practical realization of OD 203 provisions |
10.7 | ExTAG/475/CC |
Compilation of comments and observations on ExTAG/457/CD Draft ExTAG Decision Sheet – Guidance on practical realization of OD 203 provisions |
10.8 | ExTAG/460/CD |
Draft ExTAG Decision Sheet – The tensile force of cable pull test according to IEC 60079-18 |
10.8 | ExTAG/476/CC |
Compilation of comments and observations on ExTAG/460/CD Draft ExTAG Decision Sheet – The tensile force of cable pull test according to IEC 60079-18 |
10.9 | ExTAG/462/CD |
Draft ExTAG Decision Sheet – Creepage distance and clearance of on-sparking ballast according to IEC 60079-15 |
10.10 | ExTAG/471/CD |
Draft ExTAG Decision Sheet – Static versus dynamic stresses on a Sealed device |
10.11 | ExTAG/477/CD |
Draft ExTAG Decision Sheet – The resistance to impact test according to IEC 60079-0 |
10.12 | ExTAG/478/CD |
Draft Decision Sheet - The spark ignition test with super capacitor |
10.13 | ExTAG/458A/CD |
Revised Draft ExTAG Decision Sheet – Location of Electrostatic Discharge Hazard Warning |
10.13 | ExTAG/483/CC |
Compilation of comments and observations on ExTAG/458/CD Draft ExTAG Decision Sheet – Location of Electrostatic Discharge Hazard Warning |
11.2 | ExMarkCo/45A/R |
Report on 2017 Survey / Questionnaire Results from ExCBs involved in the IECEx Mark Licensing Scheme |
11.2 | ExMarkCo/047/R |
MEETING REPORT Meeting #10 of the IECEx Mark Committee (ExMarkCo) Held at CSA Group in Hawarden, UK on Thursday 11th May 2017 |